Checking Tracking
Ensure a blade is installed and properly tensioned,
and the saw is unplugged before adjusting the track-
ing. To reduce vibration and blade wear, the saw
blade’s gullet should track along the crown (the high-
est point) of the upper wheel (A).
Adjusting Blade Tracking
B
C
Make minor adjustments to the tracking knob while
rotating the upper wheel by hand (D). The blade’s
tracking position will shift as the wheel rotates, so pay
close attention to the blade’s position to avoid over ad-
justment. Once the blade is tracking correctly, tighten
the tracking knob’s jam nut to lock the blade in place.
Blade tracking should be checked every time a new
blade is installed.
A
Adjusting Blade Tracking
To adjust the blade’s tracking, first loosen the tracking
knob’s jam nut (B), then turn the tracking knob (C) to
shift the blade’s position.
D
13
Table Stop Adjustment
Setting the Table Stop Bolt
The table stop bolt allows you to easily return the table
to 90° after tilting. To adjust the 90° stop bolt, first make
sure the blade is correctly tensioned, and unplug the
saw. Then loosen the table trunnion knobs (A) and the
stop bolts locking hex nut (B).
B
A
A
Raise the upper blade guard assembly, and place a
square on the table against the blade (C). Adjust the
stop bolt to lower or raise the table until the table is
square to the blade. Re-tighten the stop bolt’s lock nut
to fix the stop bolt in place.
C
Adjust the Table Tilt Pointer
With the blade tensioned and the table set square to
the blade, loosen the pointer screw (D) and set the
pointer to 0°. Re-tighten the pointer screw to secure
the pointer
D
Summary of Contents for CWI-B1412