Set the stove at a firm and stable floor in a room that is suitable for the stove to operate in, compliant
with building regulations, and then level with adjustable feet (Fig. 4).
Figure 4. Leveling the device
Conditions for connection to mains:
•
Make sure that the mains voltage corresponds to the voltage indicated on the rating plate of the
appliance (5 Pos. 3)
•
To connect the appliance to the mains, connect the power cord to the terminal box at the bottom of
the appliance (Fig. 5 Pos. 2). The power cord with plug is NOT part of the kit and must be purchased.
•
The device must be connected to an equipotential equalization system using the equipotential screw
(Fig. 5 Pos. 1) located at the bottom of the device at the terminal box. It is marked with the following
symbol:
1
3
2
3
1
2
Rear panel components:
1.
Equipotential bolt
2.
Terminal box
3.
Rating plate
Figure 5. Rear view of unit
The power cord should be flexible, oil-resistant, earthed, polychloroprene-coated - it can be made by the
manufacturer and available from him or in specialist repair shops!
PE – protective wire (yellow-green)
N – neutral wire (blue)
L1, L2, L3 – phase wires (other colors)
Figure 6. Connecting the unit to the mains.
•
Only an authorized technician with a certificate for electrical works may connect the device to the
electrical grid.
•
The appliance should be connected to a 400V 50Hz three-phase socket equipped with a circuit breaker
In=30mA by means of a plug or directly to the power supply.
To connect the device to an electrical equalizing system:
•
loosen the nut on the screw