- 15 -
EN
4. PRODUCT CARD
Model
830130V02 830145V02
830590V02
830620V02
830621V02
Intended use
storage
storage
storage
storage
storage
Operating temperature
cooling
freezing
cooling
cooling
freezing
Category
vertical
vertical
vertical
vertical
vertical
Refrigerants
R290,
GWP=3
R290,
GWP=3
R290,
GWP=3
R290,
GWP=3
R290,
GWP=3
Parameter
Value
Annual energy consumption AEC (kWh)
1517
3259
671
1015
2351
Coefficient of energetic efficiency EEI
59
44,5
54
74
63
Net capacity V
N
(L)
1185
1185
383
465
465
(where applicable)
Refrigeration capacity V
NRef
(L)
1185
0
383
465
0
Freezing capacity V
NFrz
(L)
0
1185
0
0
465
Amount of refrigerant (kg)
0.135
0.15
0.095
0.095
0.13
5. TRANSPORT AND STORAGE
The appliance is protected with a protective film, placed on a wooden pallet, packed in a cardboard box and secured with stripes.
•
packaged appliance should be stored in a covered warehouse at an ambient temperature of 0 °C / + 55 °C and humidity of
30 - 95 %;
•
it is forbidden to stack appliances;
•
read the data on the appliance rating plate. In case of damage or loss of the rating plate it should be replaced immediately;
•
do not unscrew the safety guards;
•
after unpacking the appliance, carefully remove the protective film and other elements protecting the appliance during trans-
port;
•
while lifting the appliance with a lift, position the lift on the outside of the frame;
•
transport the appliance and store it exclusively in a vertical position. Never place the appliance on its side or upside down,
because it can damage the cooling system (not subject to warranty repair);
•
after transporting or moving the appliance wait 2 hours before starting it;
•
do not place the appliance in the vicinity of flammable products, outdoors or in a place subject to direct sunlight exposure.
6. INSTALLATION
6.1.
Positioning of the appliance
The appliance should be placed in a dry, adequately ventilated room. In order to ensure proper work
do not place the appliance near a heat source and do not expose it to direct sunlight. The optimal temperature range in the room
in which the appliance operates is between: 4 - do +30°C.
If you install the appliance in a room with high humidity level, you may need to buy an additional tray for condensed water.
Avoid placing the appliance in rooms with a high chlorine and acids content in the air (e.g.
at a pool), as this may cause corrosion of the surface made of stainless steel.
The cooling cabinet is prepared to be positioned at a wall as a free standing appliance.
Important:
The cooling cabinet should be installed in a place with proper ventilation ensuring free air circulation around the ap-
pliance. The correct distance from the rear panel of the appliance to a wall is ensured by special elements placed at the back of the
cabinet. Do not place the appliance in the vicinity of flammable products, in the open air or in a place exposed to direct sunlight.
Option. If it comes with the device:
The rubber bumpers must be screwed into the back of the unit as shown. Failure to do so will void the warranty and may cause
compressor failure
Summary of Contents for 830130V02
Page 19: ......