Stairville LED IP Bar 320/8 RGB DMX User Manual Download Page 32

7.3  Remote control functions (optional)

Use the numeric buttons on the remote control to select a desired fixed colour directly. This

setting is only relevant if the device is not controlled via DMX.

Value

Fixed colour

0

Cyan

1

Violet

2

Red

3

Orange

4

White

5

Pink

6

Green

7

Blue

8

Yellow

9

Warm white

Direct selection of a fixed colour

Operating

 

32

LED IP Bar 320/8 RGB DMX

LED Floodlight

Summary of Contents for LED IP Bar 320/8 RGB DMX

Page 1: ...LED IP Bar 320 8 RGB DMX LED Floodlight User Manual...

Page 2: ...Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 Internet www thomann de 15 07 2022 ID 347910 V8...

Page 3: ...erating elements 22 7 Operating 26 7 1 Operating on the unit 26 7 2 Menu overview 31 7 3 Remote control functions optional 32 7 4 Functions in 2 channel DMX mode 33 7 5 Functions in 3 channel DMX mode...

Page 4: ...8 Technical specifications 43 9 Plug and connection assignment 45 10 Troubleshooting 46 11 Cleaning 48 12 Protecting the environment 49 Table of contents 4 LED IP Bar 320 8 RGB DMX LED Floodlight...

Page 5: ...LED IP Bar 320 8 RGB DMX 5 LED Floodlight...

Page 6: ...le to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development W...

Page 7: ...sion to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please co...

Page 8: ...rd Meaning DANGER This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided WARNING This combination of sym...

Page 9: ...ng signs Type of danger Warning high voltage Warning hot surface Warning dangerous optical radiation Warning suspended load Warning danger zone General information LED IP Bar 320 8 RGB DMX 9 LED Flood...

Page 10: ...lities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety Extend the operatin...

Page 11: ...sing or damaged WARNING Eye damage caused by high light intensity Never look directly into the light source WARNING Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epile...

Page 12: ...connected in series must not exceed the values indicated in the technical specifications Otherwise you risk injuries and irreparable damages to the device Only connect so many identical devices that t...

Page 13: ...available infrared remote control item no 354223 and but tons and display on the unit n robust and weatherproof metal housing n splash proof connectors n Degree of protection IP65 suitable for outdoo...

Page 14: ...wever event lighting and not for permanent use outdoors The specified protection class does not make a statement about the weather resistance of the equipment resistance to changing ambient conditions...

Page 15: ...r storage respectively WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device with a...

Page 16: ...error free operation make use of dedicated DMX cables and do not use ordi nary microphone cables Never connect the DMX input or output to audio devices such as mixers or ampli fiers NOTICE Possible da...

Page 17: ...of the coupling Hand tighten the union nut You can install the device on the wall the ceiling or on the floor Two mounting brackets and the necessary screws are included Always work from a stable plat...

Page 18: ...ected against discharge by a transparent plastic foil Remove the plastic foil prior to first use NOTICE Risk of fire due to incorrect polarity Incorrectly inserted batteries may destroy the device or...

Page 19: ...Please note that this device must not be connected to a dimmer Installation LED IP Bar 320 8 RGB DMX 19 LED Floodlight...

Page 20: ...ut of the device to the DMX output of a DMX controller or another DMX device Connect the output of the first DMX device to the input of the second one and so on to form a series connection Such a chai...

Page 21: ...an automatic music controlled and synchronized show This feature is espe cially useful to start a show without much programming Connect the DMX output of the master unit to the DMX input of the first...

Page 22: ...240V 50 60Hz LED IP Bar 320 8 RGB DMX IP65 1 Power In mains cable 2 DMX In DMX input 3 DMX Out DMX output 4 Power Out power supply cable to the next unit maximum 35 further units 5 Pressure equalisat...

Page 23: ...navigates upwards in a menu list Increases the displayed value by one 9 Menu Setup enables the main menu selects an option of the respective operating mode or switches between menu items Display Menu...

Page 24: ...n be used for several device types some buttons may not be assigned and therefore have no function Infrared remote control item no 354223 optionally avail able Connections and operating elements 24 LE...

Page 25: ...mode for the programme speed Adjust the speed using and 6 STROBE activates the setting mode for the Strobe speed Adjust the speed using and 7 increases the set value 8 decreases the set value 9 Dimmi...

Page 26: ...ctivate the main menu and select an operating mode Use Up and Down to change the respectively displayed value When the display shows the desired value press Menu Setup If you don t press any button fo...

Page 27: ...set the flash frequency Use Up and Down to select a value between FS00 slow and FS99 fast For programmes Pr20 and Pr21 you can set a static colour across all segments background colour or a colour th...

Page 28: ...a master slave combination This setting is only relevant if the device is not con trolled via DMX Press Menu Setup repeatedly until the display shows Auto The playback of the selected pre programmed...

Page 29: ...and Down to select a value between 1 and 512 display shows d001 d512 Make sure that this number matches the configuration of your DMX controller The following table shows the highest possible first DM...

Page 30: ...ing DMX operating modes n 2 ch two channels n 3 ch three channels n 4 ch four channels n 7 ch seven channels n 14 ch fourteen channels n 26 ch twenty six channels This setting is only relevant if the...

Page 31: ...7 2 Menu overview SLAu AUT0 d512 d001 P 01 S 01 S 99 S FL F 00 F 99 P 02 P 22 2 ch 3 ch 4 ch 7 ch 14 ch 26 ch 1 r 2 r9 3 9 4 9b 5 b 6 rb 7 FL 8 0F Operating LED IP Bar 320 8 RGB DMX 31 LED Floodlight...

Page 32: ...a desired fixed colour directly This setting is only relevant if the device is not controlled via DMX Value Fixed colour 0 Cyan 1 Violet 2 Red 3 Orange 4 White 5 Pink 6 Green 7 Blue 8 Yellow 9 Warm w...

Page 33: ...8 LEDs off 9 17 Constant unicoloured pattern red 18 26 Constant unicoloured pattern yellow 27 35 Constant unicoloured pattern green 36 44 Constant unicoloured pattern cyan 45 53 Constant unicoloured p...

Page 34: ...153 161 Preprogrammed automatic show PR10 162 170 Preprogrammed automatic show PR11 171 179 Preprogrammed automatic show PR12 180 188 Preprogrammed automatic show PR13 189 197 Preprogrammed automatic...

Page 35: ...function if channel 1 0 71 0 255 Programme process speed if channel 1 72 255 7 5 Functions in 3 channel DMX mode Channel Value Function 1 0 255 Intensity 0 100 of the128 red LEDs 2 0 255 Intensity 0 1...

Page 36: ...LEDs 4 0 255 Intensity 0 100 of 96 blue LEDs 7 7 Functions in 7 channel DMX mode Channel Value Function 1 0 255 Dimmer 0 100 for all LEDs 2 0 255 Intensity 0 100 of the128 red LEDs 3 0 255 Intensity...

Page 37: ...72 80 Preprogrammed automatic show PR01 81 89 Preprogrammed automatic show PR02 90 98 Preprogrammed automatic show PR03 99 107 Preprogrammed automatic show PR04 108 116 Preprogrammed automatic show P...

Page 38: ...R15 207 215 Preprogrammed automatic show PR16 216 224 Preprogrammed automatic show PR17 225 233 Preprogrammed automatic show PR18 234 242 Preprogrammed automatic show PR19 243 251 Preprogrammed automa...

Page 39: ...Intensity 0 100 of the red LEDs segment 2 6 0 255 Intensity 0 100 of the green LEDs segment 2 7 0 255 Intensity 0 100 of the blue LEDs segment 2 8 0 255 Intensity 0 100 of the red LEDs segment 3 9 0 2...

Page 40: ...the red LEDs segment 1 3 0 255 Intensity 0 100 of the green LEDs segment 1 4 0 255 Intensity 0 100 of the blue LEDs segment 1 5 0 255 Intensity 0 100 of the red LEDs segment 2 6 0 255 Intensity 0 100...

Page 41: ...ment 5 16 0 255 Intensity 0 100 of the blue LEDs segment 5 17 0 255 Intensity 0 100 of the red LEDs segment 6 18 0 255 Intensity 0 100 of the green LEDs segment 6 19 0 255 Intensity 0 100 of the blue...

Page 42: ...Channel Value Function 25 0 255 Intensity 0 100 of the blue LEDs segment 8 26 0 255 Strobe effect increasing speed Operating 42 LED IP Bar 320 8 RGB DMX LED Floodlight...

Page 43: ...screw connector 3 pin and IP44 splash proof safety plug DMX control DMX cable with IP65 XLR plug 3 pin Output connections Power supply Mains cable with IP65 screw connector 3 pin DMX control DMX cabl...

Page 44: ...ange 20 C 45 C Relative humidity 20 80 non condensing Suitable for outdoor use yes Colour mixture RGB LED type Uni coloured Fanless yes Remote control optional Wireless DMX no Housing colour black Fur...

Page 45: ...e result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show A three pole coupling in IP65 design is used as DMX output a three pole plug in I...

Page 46: ...nd do not use ordi nary microphone cables Never connect the DMX input or output to audio devices such as mixers or ampli fiers In the following we list a few common problems that may occur during oper...

Page 47: ...onnection 2 If the display does not flash and still no response check the address settings and the DMX polarity 3 Try using another DMX controller 4 Check to see if the DMX cables run near or alongsid...

Page 48: ...n Clean with a soft cloth using our lamp and lens cleaner item no 280122 n Always dry the parts carefully The fan grids of the device must be cleaned of any contamination such as dust etc on a reg ula...

Page 49: ...must be disposed of in accordance with local regulations for the disposal of hazardous waste Use the existing collection points for this Only dispose of lithium batteries when they are discharged Remo...

Page 50: ...household waste Dispose of this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your...

Page 51: ......

Page 52: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Reviews: