Copyright © 2009-2017 R. STAHL TRANBERG AS. All rights reserved. Page 26 of 27
Connect according to drawings. Signal lights should be grounded to the same potential as the
panel.
Section 6.05
Technical data
Supply voltage:
2 x 230V (115V) 50/60Hz (Main and emergency supply)
Max. power consumption:
1900W
Load:
Filament lamps 20-85W
Outgoing fuses:
4.0A Fast acting. 5x20mm ceramic.
Compass safe distance:
70cm (Standard)
40cm (Standby steering emergency)
Ambient temp., operating:
0 to +55°C
Enclosure class:
IP 20
Dimension (WxHxD):
144 x 384 x 160 mm
Weight:
Max. 5.5 kg
Section 6.06
Spare parts
Description
Part No.
Main switch:
50230023
Circuit switch:
50230008
Test-button:
50230029
Dimmer potentiometer:
50211028
Main card P91:
Contact R. Stahl Tranberg A.S
LED card P93:
Contact R. Stahl Tranberg A.S
Transformer card P99:
3467
Power relay:
50 50 50231035
Fused terminal block:
50 50281173
Fuse 4.0A 5x20mm:
50232003