10.
LONG-TERM STORAGE
lf store the generator set for long periods, make the following
preparations:
1.
Run the engine for about 3 minutes and then stop.
2.
Stop the engine. Drain the engine oil while the engine is
stilI warm and fill with fresh oil.
3.
Remove the screw plug on the cylinder head cover and
refill 2cc engine oil, then put the plug in place.
4.
Recoil starting:
Push the decompression lever down
(Non-compression position) and hold it while you pull the
recoil starter 2~3 times. (Do not start the engine.)
Electric starting:
Turn the engine 2~3 seconds with the decompression lever set at the
non-compression position, and the starting key at the "START" position. (Do not start the engine.)
5.
Pull the decompression lever up. Pull the recoil starter slowly. Stop when you feel
resistance. (at this position, both intake/exhaust valves are closed to prevent the engine
from the rust.)
6.
Disconnect battery negative wiring.
7.
Drain out the fuel and clean the sediment from fuel tank, wipe off the genset. Lubricating all
connecting points of speed governor system.
8.
Check and service the genset per the maintenance schedule prior to storage.
9.
Cover the genset with a plastic cover to keep water and dust away from the genset and
store in a dry area.
10.
Charge battery every one month.
11.
Store the genset in a well-ventilated area and free from moisture and dust.
12.
Perform the steps in Chapter 4 before starting genset after a long-term storage.
11.
TROUBLESHOOTING AND REMEDY
Fault Cause
Remedy
The diesel
engine can not
start
Fuel oil is not sufficient
Refill the fuel oil
Fuel cock is not at START position
Turn it to START position
Fuel injection pump and nozzle do not delivery the
fuel or delivery in-sufficient fuel.
Remove the nozzle and repair at test table.
The governor lever is not at START position.
Set the lever to START position
Check the engine oil level.
The specified oil level should be between the
upper level and lower level.
The nozzle has dirty.
Clean the nozzle
The speed and force to pull the recoil starter are
not enough.
Start the engine according to the start procedures
included in this book.
The battery has no electricity.
Charge it or replace it with a new one.
The generating
set cannot
generate
Main switch not be turned on.
Turn the main switch to ON position.
The carbon brush already worn.
Replace the carbon brush.
The contact of the socket is not good.
Adjust the socket.
The rated speed cannot attached.
Adjust it according to the requirements.
AVR is damaged.
Replace the AVR.
Ver. 3/Rev. 1; Data: 03.02.2022;
50
Summary of Contents for YDE6500E
Page 9: ...3 CONFIGURATION 3 1 Parts illustration YDE X E X3 E3 series Ver 3 Rev 1 Data 03 02 2022 35 ...
Page 10: ...3 1 Parts illustration YDE T T3 TD TD3 series Ver 3 Rev 1 Data 03 02 2022 36 ...
Page 15: ...Recoil starting Ver 3 Rev 1 Data 03 02 2022 41 ...
Page 16: ...Ver 3 Rev 1 Data 03 02 2022 42 ...
Page 26: ...12 3 Wiring diagram Wiring diagram for YDE6500E Ver 3 Rev 1 Data 03 02 2022 52 ...
Page 27: ... Wiring diagram for YDE6500E3 Ver 3 Rev 1 Data 03 02 2022 53 ...