Description 

• Primary heating up takes very short time, only about 40 seconds,

 

shorter than general 

haze

 machines.

• The innovative heating preservation function of the heater,

under status of standby, heater keeps heating up steadily by lower

 

temperature to protect the heating pipe to prolong the life.

• Drying, stable and smoothly smoke output control from 0-100%.

 

High quality smoke, with smooth fan effect, so that the effect of

 

smoke thinner and more uniform.

• The hanging bracket of the machine can be used as a tripod and do

 

a variety of angles setting.

• Excellent design of 3-liter liquid tank has no worry of oil leaking

 

when being operated up spray or forward spray. Quick connector

 

makes replacement direct and easier when performance is ongoing.

• DMX on board, 3 DMX modes for choice; 1CH, 2CH, 4CH, operate

 

by any additional DMX controller.

• Built-in multi-function operation control. Built-In timer control and

 

continuous fogging control.

• Equipped with 0-90 degree adjustable air deflector.
• Heavy-duty.  Able to keep working long time.
• Self-cleaning function: The machine design of machine stops

 

working after a delay of 100 seconds, automatically clear the tubing

 

of the remaining liquid.

• Easy understanding LED screen and intelligent design of software

 

control.

• Could be used with the VT-1 controller (optional). Simple and user-  
friendly design makes 

MYSTYQUE 400 DMX

 easier to use.

• The streamline housing could be hanging, side hanging, landing

 

installation, easy to set in various occasions.

Summary of Contents for MYSTYQUE 400 DMX

Page 1: ...User manual ENGLISH MYSTYQUE 400 DMX Version 1 1...

Page 2: ...t Specification 20 CONTENTS If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Read the manual Indoor use...

Page 3: ...nd tighten the tank cap securely to avoid spilling Without user serviceable parts in the package please contact your local agent or qualified technician for servicing Thank you for selecting our DMX h...

Page 4: ...o air vents Allow 100CM space or above around the machine for proper ventilation Keep haze machine away from flames and flammable items Never aim the nozzle at open flames or sparks Use only high qual...

Page 5: ...or immediately If fluid contacts eyes or skin rinse skin thoroughly with water Read user manual instructions thoroughly before operating Follow the instruction Never remove warning or informative labe...

Page 6: ...ted on the user manual If accident happens because users do not install the product according to the instruction of the user manual the manufacturer will not take any responsibility Please note Specif...

Page 7: ...E Air Deflector F Sponge G Smoke Output H LED Display I 4 Function Buttons J Control Socket Connection Figure1 DMX HAZE Functions C D B O P E A F G K DMX 3 pin XLR Output L DMX 3 pin XLR Input M Manu...

Page 8: ...up spray or forward spray Quick connector makes replacement direct and easier when performance is ongoing DMX on board 3 DMX modes for choice 1CH 2CH 4CH operate by any additional DMX controller Buil...

Page 9: ...Mounting MYSTYQUE 400 DMX is shipped complete ready to use The bracket is installed before shipping the unit can be hung in any position Fasten the effect fan onto firm trussing Use a 15 kg rated or...

Page 10: ...itely water based liquid of good quality 5 Plug mains power cord from the haze machine into appropriate power supply socket Wait about 40 seconds for heating element to heat up 6 Use LED display for o...

Page 11: ...mation 5 pin XLR 3 pin XLR 1 Ground 1 Ground 1 Ground 1 Ground 2 Cold 2 Cold 2 Cold 2 Cold 3 Hot 3 Hot 3 Hot 3 Hot 4 N A 4 N A 5 N A 5 N A XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment nega...

Page 12: ...y and fast pressed UP DOWN at the same time value back to 1 DMX mode selection Single channel 2 channels and 4 channels mode can be selected Setting output of timing fogging and continuous fogging Vol...

Page 13: ...f automatic inspection of fluid volume 1 When this function is 0 means OFF the machine cannot inspect volume of the fluid This means that the machine will keep working even there s no fluid 2 When thi...

Page 14: ...have the control priority turn the knob to OFF then to ON 3 Pressing Manual Fog button or Timer button of the control panel to let it get the control priority Important The one which controls the last...

Page 15: ...0 Press Manual Fog to starts continuous fogging status the red dot will run circularly After setting the interval and duration press Timer to start timing fogging the display will shows decreasing in...

Page 16: ...e do not unplug the machine immediately but wait 100 seconds to let the machine automatically clean the fluid left in the pipe This is to avoid causing negative effect when used next time The LED scre...

Page 17: ...VT 1 wired controller Controller power cord length 3 m Connector 1 4 stereo jack Function Air volume adjustment ON OFF Model VT 1 Cable Length 3m Effective Distance N A Connector 1 4 stereo jack Func...

Page 18: ...e in to the output socket figure 1 K on the back of the first machine plug the other end of the signal cable to the input socket figure 1 I on the back of the second machine Follow the same procedure...

Page 19: ...8 255 ON 10 255 10 255s 2 255 20 2550s 0 127 OFF 0 9 0s 0 1 0s s seconds Interval 0 means constant fog When the smoke state is off volume 0 the timer does not work the LED screen of the machine shows...

Page 20: ...flow or not 5 Check if the heater is heating touch the panel to see if it is warming 6 Check your controller if in correct connection 7 Check your DMX address setting Power Connected Fog Blasts not Sm...

Page 21: ...n normal smoke condition is unclear stop running to avoid any damage shut down to cool it and bring unit to your local agent or appointed service place for inspection prohibit any dismantlement by you...

Page 22: ...urities periodically use tools to clean the nozzles keep the nozzle unobstructed 3 Prolonged use please clean the air inlet regularly 4 Prolonged use sponge inside the vent may accumulate oil periodic...

Page 23: ...g Continuous Fogging Fuse 100V 120V 250V 6 3A Fuse 230V 240V 250V 4A Display LED Screen Tank liters 3L Fog Output cu ft min 4000 Warm Up time seconds 40s Fluid Consumption ml min 4 5ml min Date Connec...

Page 24: ...Save this instruction properly All the information is subject to change without prior notice M YSTYQ UE 400 D M X...

Reviews: