Stafor COMBI 200TDHW Installation And User Manual Download Page 12

INSTALLATION AND USER MANUAL 
200TDHW 

 

12 

V0REV1EN0218

 

 

11.

 

COMISSIONING. CONTROLLER. 

11.1.

 

User interface description 

  

 

 

 

 

 

 

 

 

N

av

ig

at

io

ke

ys

 

 

Mode selection key 

M

od

es

 

 

Vacation mode indication 

 

Increase and navigation key 

 

 

Program mode indication 

 

Decreas e and navigation key 

Ti

m

In

fo

 

 

Ti me setting 

 

Validation key 

 

Information 

M

od

es

 

 

 

Eco mode indication 

Ind

ic

at

or

s

 

 

 

Heat  pump in operation 

 

Auto mode indication 

 

 

Heating element in operation 

 

 

 

Boost mode indication 

 

Off-peak ins tal lation 

 

 

 

 

4 characters 

 

 

 

 

Programming time slot ( 15 min each) 

 

 

iFH 200 foreground instruction book 

 

 

 

 

 Z.I. Les levées, 38470 VINAY, FRANCE , 

 

Tel. +33 4 76 36 82 97, Fax +33 4 76 64 05 43

 

 

 

 

IFH 200 IB V1.3 

-   CONFIDENTIAL   - This file is the exclusive property of COTHERM and cannot be in any case reproduced or communicated to 

a third party

 

without Cotherm prior agreement

 

 

P. 3 

 

INTRODUCTION: 

 
iFH Foreground is the generic term to designate the display module that enable a end-user to control a water heater equipped 
with iQuaFlex® iHPC Background. This document describes the user interface of standard iQuaFlex® foreground solution.  
Partial of full customized foreground are possible according to customer demands. 

USER INTERFACE DESCRIPTION  

 

Mode selection key

Vacation mode indication

Increase and navigation key

Program mode indication

Decrease and navigation key

Ti

m

e

Time setting

Validation key

In

fo

Information

Eco mode indication

Heat pump in operation

Auto mode indication

Heating element in operation

Boost mode indication

Off-peak installation 

Programming time slot (15 min. each)

Na

vi

ga

ti

o

n

 k

e

ys

Mo

d

e

s

 M

o

d

e

s

In

d

ic

at

o

rs

4 caracters indicateurs

 
 

Summary of Contents for COMBI 200TDHW

Page 1: ...INSTALLATION AND USER MANUAL 200TDHW...

Page 2: ...The installer has the responsibility to install the minimum safety devices hydraulic and electrical set out in this Manual In case of failure the lack of any device may cause burns or other injuries T...

Page 3: ...ation site always introducing the forks into the bottom of the pallet being careful not to damage the unit In case you identify any damage at the time of the reception of the unit it is mandatory to r...

Page 4: ...INSTALLATION AND USER MANUAL 200TDHW 4 V0REV1EN0218 Figure 2 Exploded view...

Page 5: ...02 E 161 F 250 Figure 4 Front connections Figure 5 Back connections F Refrigerant inlet G Refrigerant outlet H Power supply 230V 1PH 50 HZ I Condensate drain J Hot water outlet K Cold water inlet L Re...

Page 6: ...Cylinder 200DHW Capacity L 200 Maximum operating pressure bar 6 Heat pump data Energy Efficiency Class A Load profile L Heating capacity range W 1430 2560 Input power range W 450 540 Maximum temp HP C...

Page 7: ...ric installation 10 Commissioning 11 Adjustment of refrigerant load 5 THERMODYNAMIC SOLAR PANEL INSTALLATION 5 1 Site selection The choice of the installation site of the thermodynamic panel is a key...

Page 8: ...ng pieces 6 x Aluminium support L shape 6 x Screws M5 12 x Nuts M5 18 x Washer 5 18 x Sheet Metal Screws 18 x Blocks M6 Anchor the panels using the lateral and front holes to the suitable surface 1700...

Page 9: ...s Panels are supplied with two nuts for the inlet and outlet connection The inlet to each panel is 1 4 inch diameter The installer has to insert the nut into the copper pipe flare the pipe and then us...

Page 10: ...absence of leaks 7 3 Vacuum Connect the vacuum pipe to the pressure gauge to carry out a vacuum of the whole installation 7 4 Coolant filling Open the load ports to fill the circuit with the refriger...

Page 11: ...ronic device is installed inside the ECOHEAT together with the controller and has a LED indicator in the bottom CAUTION To check the proper functioning of the anode the tank should be plenty of water...

Page 12: ...of COTHERM and cannot be in any case reproduced or communicated to a third party without Cotherm prior agreement P 3 INTRODUCTION iFH Foreground is the generic term to designate the display module th...

Page 13: ...co mode with blinking horizontal segment Blinking segment indicates a first installation or a power shut down exceeding 24h By pressing any key default set temperature will be display At first install...

Page 14: ...perature and inner performances of the heat pump during programming period Information Provides weekly or monthly statistics on heat source usage given about the real usage of the heat pump source or...

Page 15: ...his setting is mandatory before using program mode Select the clock mode to set hours minutes and days In time setting mode the display indicates alternatively the current day and time setting Pressin...

Page 16: ...o back to the operating mode selected before Boost 11 7 Out of home Out of Home mode may be set for long absence period limiting energy consumption during this period In Out of Home mode 200TDHW will...

Page 17: ...e symbol appears at the top of the display In Program mode 200TDHW will switching automatically between heat pump and heating element based on the input air temperature and inner performances of the h...

Page 18: ...s been correctly installed and connected in Off peak or Night tariff configuration In this configuration Program mode is not applicable and it is automatically disabled The off peak detection can be a...

Page 19: ...sage Child UNLOCK confirmation message 11 14 Information information selectable by pressing mode button gives access to statistical information iFH 200 foreground instruction book Z I Les lev es 38470...

Page 20: ...Backlight will automatically turn off after a time out of 10s without user interaction 11 16 Photovoltaic option 200TDHW enable the interface with a photovoltaic energy manager or inverter With this o...

Page 21: ...menu is accessible by a simultaneous pressing of and keys This menu enables to perform testing for maintenance purposes and to change mandatory setting due to installation configuration Setting param...

Page 22: ...ff PV function Off Default Value from 1 to 20 Minimum Sun exposure duration before PV ON in Minute I4 0 or 1 1 Anti legionella ON 0 Anti legionella OFF t 1 2 digits NTC1 temperature value t 2 2 digits...

Page 23: ...AL This file is the exclusive property of COTHERM and cannot be in any case reprod a third party without Cotherm prior agreement DIAGNOSTIC iHPC give an error code in case of abnormal operation Error...

Page 24: ...ON AND USER MANUAL 200TDHW 24 V0REV1EN0218 STAFOR 53a Kuldigas str Riga Latvia LV1046 www stafor lv info stafor lv This company reserves the right to modify the information contained herein without pr...

Reviews: