Lined Filter Strainer (Y Type) (3)
-
Pressure reducing valve (5)
-
Expansion vessel (2)
-
Safety valve (6)
Once the hydraulic connections are made, vent the circuit to avoid the air inside the installation.
9.
ELECTRICAL CONNECTION
The power supply of the system is 230/1/50 Hz.
10.
CURRENT IMPRESSED ANODE
The system incorporates as standard an impressed current anode that automatically protect the tank
against the corrosion. The electronic device is installed inside the ECOHEAT, together with the
controller and has a LED indicator in the bottom.
CAUTION: To check the proper functioning of the anode, the tank should be plenty of water.
The user should check regularly the state of the anode through the LED indicator:
-
LED is highlighted in green: Correct operation of the anode
-
LED off: Check the power supply. If it is correct, contact with the installer for an
inspection.
Once the hydraulic connections are made, vent the circuit to avoid the air inside the installation.
NTC1: In tank water
temperature
I1-I2: To inverter
C2-C1: Off-peak signal
D: Display connection
P: Pressostat
R: Electrical element
K: Compressor