STACK ST8150 Display System
Chapter 4. Configuring the Display System
User Guide Addendum
9
Chapter 4. Configuring the Display System
Configuration mode
The list of configurable parameters has changed significantly from that
of the ST8100. Please note that the settings for the 30PSI/150PSI
FUELP SENSOR (2BAR/10BAR for EC) must match the sensor fitted or
incorrect readings will be shown.
Configurable
Parameter
Setting Required
Switchable
Parameter
E.S.Cylinders
Number of cylinders in engine (for RPM)
Not
Applicable
GATE RPM
Minimum RPM for the Fuel Pressure, Oil
Temperature and Pressure, and Water
Temperature warnings to operate.
Yes
LOG RPM
RPM at which the logging option is started.
No
SHIFT RPM
RPM at which gear shift light is to come on
Yes
HIGH WATER
Maximum water temperature alarm
Yes
HIGH OIL T
Maximum oil temperature alarm
Yes
LOW FUEL P
Minimum fuel pressure alarm
Yes
LOW OIL P
Minimum oil pressure alarm
Yes
LOW BATT
Minimum battery voltage alarm
Yes
HIGH BOOST
Maximum boost pressure alarm
Yes
HIGH EGT
Maximum EGT alarm
Yes