Peak Values (Tell Tales)
The system stores either a maximum or a minimum value as the peak
value, depending on the parameter, as follows:
Parameter
Type of Peak
Value
Gated to RPM
Oil Temperature
Maximum
Yes
Water Temperature
Maximum
Yes
Oil Pressure
Minimum
Yes
Fuel Pressure
Minimum
Yes
Battery Voltage
Minimum
Yes
Boost Pressure
Maximum
Yes
Exhaust Gas
Temperature
Maximum
Yes
Resetting the Peak Values
The peak values for the channels will reset as follows:
Parameter
New Peak Value
Boost Pressure
-99.9 Bar
Oil Pressure
999 PSI
Fuel Pressure
999 PSI
Oil Temperature
0C
Water Temperature
0C
Exhaust gas Temperature
-99C
Battery Voltage
26.0V