8
SUPERMAX
®
VS Variable Speed Pump Installation and User’s Guide
Custom Schedules
To customize the run schedule for your SuperMax
®
VS
Variable Speed Pump, the pump must be stopped. Be
sure that the
Start/Stop
button LED is not illuminated.
Programming a Custom Schedule:
Note:
When programming, the LED light next to the
parameter (“Speed”, “Time” and “Duration”) you are
setting will blink.
1. Stop the pump if it is running by pressing the
Start/
Stop
button.
2. Press the “
1
” button. The LED above the selected
SPEED will begin to blink and the “Speed” parameter
LED will blink while editing. See
Figure 7
.
3. Use the “
+
” and “
-
” arrows to adjust the speed in
RPM for SPEED 1.
Note:
Speed is adjusted up or down by increments of
10 RPM.
4. Press the “
1
” button again and the display will
change to SPEED 1 start time. The “Time”
parameter LED will begin to blink. See
Figure 8
.
5. Use the “
+
” and “
-
” arrows to adjust the daily start
time for SPEED 1.
3000
Figure 7:
Setting Speed
8:00
AM
Figure 8:
Setting Start Time
6. Press the “
1
” button again and the display will change
to SPEED 1 duration. The “Duration” parameter LED
will begin to blink. See
Figure 9
.
7. Use the “
+
” and “
-
” arrows to adjust the duration for
SPEED 1 in hours and minutes.
Note:
The duration parameter is adjusted in 15
minute increments.
8. Pressing the “
1
” button will continue to cycle through
these parameters, but the changes are immediately
saved as they are adjusted.
9. Press the “
2
” button. The LED above SPEED 2 will
begin to flash and the corresponding parameter LED
will flash while editing.
10. Use the “
+
” and “
-
” arrows to adjust the speed in RPM
for SPEED 2.
11. Press the “
2
” button again and the display will change
to SPEED 2 duration.
Note:
SPEEDs 2 and 3 do not have a start time,
as they begin their duration immediately after the
previous SPEED finishes.
12. Use the “
+
” and “
-
” arrows to adjust the duration for
SPEED 2 in hours and minutes.
13. Repeat steps 9-12 to program SPEED 3 and QUICK
CLEAN.
Note:
Remember that the duration allowed for
SPEED 3 will be limited to the remaining time in
a 24 hour day. Any time in the 24 hour day not
programmed into SPEEDs 1-3, the pump will remain
in a stationary state.
[ SPEED 1 + SPEED 2 + SPEED 3 < 24 Hours ]
14. Press the
Start/Stop
button and ensure the LED is
lit. The pump is now on and will run the custom user-
programmed schedule.
Note:
If the pump has been stopped via the
Start/
Stop
button, the pump will not run until the pump is
turned back on by the
Start/Stop
button. If the
Start/
Stop
LED is illuminated then the pump is on and will
run the programmed schedule.
2:00
Figure 9:
Setting Duration