background image

7

Pump suctions are hazardous and can trap and drown or disembowel bathers.
Do not use or operate pump, pool or spa if a suction outlet cover is missing,
broken, or loose. Follow the guidelines below for a pump installation which
minimises risk to users or pools and spas.

Entrapment Protection

The pump suction system must provide protection against hazard of suction
entrapment or hair entrapment/entanglement.

Testing and Certifi cation

Suction outlet covers must have been tested by a nationally recognised
testing laboratory and found to comply with the latest AS1926.3 standard or
ASME/ANSI specifi cation for Suction Fittings For Use in Swimming Pools,
Spas, Hot Tubs, and Whirlpool Bathtub Applications.

Outlets Per Pump

Provide at least two hydraulically balanced main drains, with covers, for each
swimming pool pump suction line. The centres of the main drains (suction
fi ttings) must be at least 800mm apart.
The system must be built so that it cannot operate with the pump drawing
water from only one main drain (that is, there must be at least two main drains
connected to the pump whenever it is running). However, if two main drains
run into a single suction line, the single suction line may be equipped with a
valve which will shut off both main drains from the pump.
More than one pump can be connected to a single suction line as long as the
requirements above are met.

Water Velocity

The maximum water velocity through any suction outlet must comply with
the latest AS1926.3 Standard or ASME/ANSI Specifi cation for Suction
Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub
Applications.

Summary of Contents for SilentFlo SF1100100

Page 1: ...should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product For the Installation Operation and Service of SilentFlo Pool Pum...

Page 2: ...p Mount 5 Teflon Taping Instructions 6 Fittings 6 Pool Outlets 6 Entrapment Protection 7 Testing and Certification 7 Outlets per Pump 7 Water Velocity 7 Electrical 8 Operation 9 Priming Pump 10 Servic...

Page 3: ...n to suit 50mm I D PVC pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm I D PVC pipe to AS NZS 1477 Max Working Pressure 260 kPa Water Temperature Range 5 C 38 C IP Rating IPX5 Elect...

Page 4: ...n cause explosion Ensure all air is out of the system before operating or testing equipment Silentflo is electrically connected Ensure that it is isolated from electrical supply during installation an...

Page 5: ...e it is ready for operation Remove trap lid and retighten hand tight only Fire and burn hazard Modern motors run at high temperatures To reduce risk of fire do not allow leaves debris or foreign matte...

Page 6: ...teners 3 Allow pump suction inlet height to be as far below water level as possible 4 Allow use of short direct suction pipe to reduce friction losses 5 Allow for shut off valves in suction and discha...

Page 7: ...s possible To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump Never use a suction pipe smaller than pump suction connections 2 50mm To...

Page 8: ...utlets Per Pump Provide at least two hydraulically balanced main drains with covers for each swimming pool pump suction line The centres of the main drains suction fittings must be at least 800mm apar...

Page 9: ...l system Do not use extension leads as they are unsafe in and around the Pool Zone Incorrect voltage can cause fire or seriously damage pump and voids warranty Voltage at pump must not be more than 6...

Page 10: ...AYS have close adult supervision Pump suction is hazardous and can trap and drown or disembowel bathers Do not use or operate pump pool spas if a suction outlet cover is missing broken or loose Follow...

Page 11: ...ump with water Do not lubricate the trap lid o ring The original equipment O ring contains a permanent internal lubricant If the o ring needs replacement insist on genuine Onga service parts Clean and...

Page 12: ...and clean Ensure all holes in basket are clear flush basket with water and replace in trap with large opening at pipe connection port between ribs provided If basket is replaced backwards the cover wi...

Page 13: ...rom sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer verti...

Page 14: ...ppliance that is known to work to check power outlet Blown fuse Circuit breaker Check and call electrician if necessary Motor burnt out due to voltage spike or flooded by water The motor may need repl...

Page 15: ...ket lid o ring 1 11 Shaft seal 1 3 Lint Pot 1 12 Shaft seal ceramic 1 4 Barrel unions 2 13 Seal Plate 1 6 Pump casing 1 17 Motor 1 7 Casing o ring 1 18 Motor pad 1 8 Diffuser o ring 1 19 Base 1 9 Diff...

Page 16: ...15 Notes...

Page 17: ...16 Notes...

Page 18: ...e warranty period then Pentair Water will at its sole option repair or replace the product with a like product Replacement product or parts may include re manufactured or refurbished parts or componen...

Page 19: ...Warranty service work will be denied or suspended on equipment not readily accessible to service personnel that is products that are behind barriers tiled or bricked in installed in roofs or second s...

Page 20: ...specifications Pacific Head Office Australia Pentair Water Australia Pty Ltd Notting Hill Victoria Australia Tel 1300 137 344 Int Tel 613 9574 4000 Fax 1800 006 688 Int Fax 613 9562 7237 Email au sal...

Reviews: