background image

3

READ AND FOLLOW SAFETY
INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your sys-

tem or in this manual, look for one of the following signal words and

be alert to the potential for personal injury.

warns about hazards that will cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that can cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that will or can cause minor personal

injury or property damage if ignored.

NOTICE indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equip-
ment. 
Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. 
Read and follow instructions in owner's manual when installing
and operating equipment. Have a trained pool professional per-

form all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system

before operating or testing equipment.

Before pressure testing, make the following safety checks:

Check all clamps, bolts, lids, and system accessories before testing.
Release all air in system before testing.
Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque for testing.
Water pressure for test must be less than 25 PSI (7.5 kg/cm

2

).

Water Temperature for test must be less than 100

o

F. (38

o

C).

Limit test to 24 hours. After test, visually check system to be sure it is ready
for operation. Remove trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For 
non-Sta-Rite equipment, consult manufacturer.

Motor normally operates at high temperature and will be too

hot to touch. It is protected from heat damage during operation by an auto-
matic internal cutoff switch. Before handling pump or motor, stop motor and
allow it to cool for 20 minutes.

IMPORTANT
SAFETY 
INSTRUCTIONS

Always follow basic safety pre-
cautions with this equipment,
including the following.

To reduce the risk

of injury, do not permit children
to use this product unless they
are closely supervised at all
times.

This pump is for use

with permanently installed pools
and may also be used with hot
tubs and spas if so marked. Do
not use with storable pools. A
permanently installed pool is
constructed in or on the ground
or in a building such that it can-
not be readily disassembled for
storage. A storable pool is con-
structed so that it may be readily
disassembled for storage and
reassembled to its original
integrity.

SAVE THESE 
INSTRUCTIONS

Summary of Contents for DURA-GLAS

Page 1: ...2G3 122 P2RA52G3 126 2 1 2 P2RAA52G3 122 Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 49...

Page 2: ...Y The Sta Rite P2R and P2RA Series Self priming Centrifugal pump Is designed for use with swimming pools or as a centrifugal pump Is an excellent performer durable reliable Table of Contents Safety In...

Page 3: ...y checks Check all clamps bolts lids and system accessories before testing Release all air in system before testing Tighten Sta Rite trap lids to 30 ft lbs 4 1 kg m torque for testing Water pressure f...

Page 4: ...E Use Teflon tape or Plasto Joint Stik1 for making all threaded connections to the pump Do not use pipe dope pipe dope will cause stress cracking in the pump NOTICE Pump suction and discharge connecti...

Page 5: ...l Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction 5 TABLE I RECOMMENDED FUSING AND WIRING DATA P2RA Series Motor Branch Fuse...

Page 6: ...size and type wire required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG or larger Run wire from external...

Page 7: ...will depend on vertical length of suc tion lift and horizontal length of suction piping If pump does not prime make sure that all valves are open suction pipe end is under water and that there are no...

Page 8: ...period Have a qualified serviceman repair wiring as needed 4 Inspect and tighten all watertight connections 5 Open all valves in suction and return piping 6 Remove any winterizing plugs in piping syst...

Page 9: ...leak 4 Remount seal plate to motor Tighten bolts to 60 80 inch lbs 69 92 cm kg torque 5 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 6 Slide rotating seal membe...

Page 10: ...impeller is not clogged follow steps 1 through 7 under Removing Old Seal Page 8 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 9 for reassembly 8 Impeller and dif...

Page 11: ...11 19 Washer Flat 2 U43 42SS 20 Screw 3 8 16 x 1 3 4 Hex Head 2 U30 77SS 21 Screw 3 8 16 x 1 Hex Head 2 U30 74SS Reducer 2 x 1 1 2 1 C78 7P Tag CAUTION This pump equipped 61002 0002 with mechanical sh...

Page 12: ...Pad 1 C35 11 19 Washer Flat 2 U43 42SS 20 Screw 3 8 16 x 1 3 4 Hex Head 2 U30 77SS 21 Screw 3 8 16 x 1 Hex Head 2 U30 74SS Reducer 2 x 1 1 2 1 C78 7P Tag CAUTION This pump equipped 61002 0002 with me...

Page 13: ...otherwise indicated Overhaul Kits Parts Pak Number H P P2R P2RA 1 2 PP1011 PP1010 3 4 PP1014 PP1011 1 PP1016 PP1014 1 1 2 PP1018 PP1016 2 PP1018 Kit includes Impeller Diffuser Shaft Seal Gaskets O Ri...

Page 14: ...ence misapplication improper installation or maintenance or other circum stances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Reviews: