background image

8

Draining Pump:

1. Pump down water level below all inlets to the pool.

To avoid dangerous or fatal electrical shock hazard, turn OFF power

to motor before draining pump.

2. Gravity drain system as far as possible.
3. Remove trap cover and use low pressure (5 PSI or less) air to blow accu-

mulated water from the piping system. Use a Sta-Rite U79-11 Lid Wrench
to remove trap covers that have been overtightened or have taken a set
and cannot be removed by hand. 

4. Protect areas which retain water with non-toxic propylene glycol

antifreeze (“RV antifreeze”).

5. Cap inlet piping after draining to keep water out of the pipes.
6. To prevent pump from freezing, remove trap cover and drain the tank

body through the drain plug (Key No. 18, Page 11). Clean pump thor-
oughly; replace trap cover.
NOTICE: Tighten trap cover by hand only (no wrenches)! Use a wrench
only if necessary to remove cover!

7. Be sure motor is kept dry and covered.

Startup For Winterized Equipment:

1. Remove any temporary weather protection placed around system for shut-

down.

2. Follow filter manufacturer’s instructions for reactivation of the filter.
3. Inspect all electrical wiring for damage or deterioration over the shutdown

period. Have a qualified serviceman repair wiring as needed.

4. Inspect and tighten all watertight connections.
5. Open all valves in suction and return piping.
6. Remove any winterizing plugs in piping system.
7. Drain all antifreeze from system.
8. Close all drain valves and replace all drain plugs in piping system.
9. Prime pump according to instructions on Page 7.

PUMP SERVICE

Pump should only be serviced by qualified personnel.
Be sure to prime pump (Page 7) before starting.

Before removing trap cover:

1. STOP PUMP before proceeding.
2. CLOSE GATE VALVES in suction and discharge pipes.
3. RELEASE ALL PRESSURE from pump and piping system.
4. NEVER tighten or loosen clamp while pump is operating!

To avoid dangerous or fatal electrical shock hazard, turn OFF power

to motor before working on pump or motor.

Aside from lubricating trap cover O-Ring, no lubrication or regular mainte-
nance is needed beyond reasonable care and periodic cleaning.
If shaft seal is worn or damaged, repair as follows:

Pump Disassembly/Removing Old Seal:

Disconnect power to pump motor.

Be sure gate valves on suction and return piping are closed before starting
work.
Release all pressure by opening all vents before starting work.
1. Drain pump by removing drain plugs on bottom of pump body and trap

body.

FIGURE 3

Hazardous voltage.
Can shock, burn,
or cause death.

Disconnect power
before working
on pump or motor.

Summary of Contents for DURA-GLAS

Page 1: ...2G3 122 P2RA52G3 126 2 1 2 P2RAA52G3 122 Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 49...

Page 2: ...Y The Sta Rite P2R and P2RA Series Self priming Centrifugal pump Is designed for use with swimming pools or as a centrifugal pump Is an excellent performer durable reliable Table of Contents Safety In...

Page 3: ...y checks Check all clamps bolts lids and system accessories before testing Release all air in system before testing Tighten Sta Rite trap lids to 30 ft lbs 4 1 kg m torque for testing Water pressure f...

Page 4: ...E Use Teflon tape or Plasto Joint Stik1 for making all threaded connections to the pump Do not use pipe dope pipe dope will cause stress cracking in the pump NOTICE Pump suction and discharge connecti...

Page 5: ...l Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction 5 TABLE I RECOMMENDED FUSING AND WIRING DATA P2RA Series Motor Branch Fuse...

Page 6: ...size and type wire required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG or larger Run wire from external...

Page 7: ...will depend on vertical length of suc tion lift and horizontal length of suction piping If pump does not prime make sure that all valves are open suction pipe end is under water and that there are no...

Page 8: ...period Have a qualified serviceman repair wiring as needed 4 Inspect and tighten all watertight connections 5 Open all valves in suction and return piping 6 Remove any winterizing plugs in piping syst...

Page 9: ...leak 4 Remount seal plate to motor Tighten bolts to 60 80 inch lbs 69 92 cm kg torque 5 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 6 Slide rotating seal membe...

Page 10: ...impeller is not clogged follow steps 1 through 7 under Removing Old Seal Page 8 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 9 for reassembly 8 Impeller and dif...

Page 11: ...11 19 Washer Flat 2 U43 42SS 20 Screw 3 8 16 x 1 3 4 Hex Head 2 U30 77SS 21 Screw 3 8 16 x 1 Hex Head 2 U30 74SS Reducer 2 x 1 1 2 1 C78 7P Tag CAUTION This pump equipped 61002 0002 with mechanical sh...

Page 12: ...Pad 1 C35 11 19 Washer Flat 2 U43 42SS 20 Screw 3 8 16 x 1 3 4 Hex Head 2 U30 77SS 21 Screw 3 8 16 x 1 Hex Head 2 U30 74SS Reducer 2 x 1 1 2 1 C78 7P Tag CAUTION This pump equipped 61002 0002 with me...

Page 13: ...otherwise indicated Overhaul Kits Parts Pak Number H P P2R P2RA 1 2 PP1011 PP1010 3 4 PP1014 PP1011 1 PP1016 PP1014 1 1 2 PP1018 PP1016 2 PP1018 Kit includes Impeller Diffuser Shaft Seal Gaskets O Ri...

Page 14: ...ence misapplication improper installation or maintenance or other circum stances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Reviews: