INSTALLATION

Only qualified, licensed personnel should install pump and wiring.

Pump mount must:
Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe
stress, bolt pump to mount.)
Allow pump suction inlet height to be as close to water level as possible.
Allow use of short, direct suction pipe (To reduce friction losses).
Allow for gate valves in suction and discharge piping.
Have adequate floor drainage to prevent flooding.
Be protected from excess moisture.
Allow adequate access for servicing pump and piping.

NOTICE: Use Teflon tape or Plasto-Joint Stik

1

for making all threaded

connections to the pump. Do not use pipe dope; pipe dope will cause
stress cracking in the pump.

NOTICE: Pump suction and discharge connections have molded in
thread stops. DO NOT try to screw pipe in beyond these stops.

Teflon Taping Instructions:

Use only new or clean PVC pipe fittings.
Wrap male pipe threads with one to two layers of Teflon tape. Cover
entire threaded portion of pipe.
Do not overtighten or tighten past thread stop in pump port!
If leaks occur, remove pipe, clean off old tape, rewrap with one to two
additional layers of tape and remake the connection.

NOTICE: Support all piping connected with pump!

1

Lake Chemical Co., Chicago, Illinois

4

FIGURE 1

Summary of Contents for DURA-GLAS

Page 1: ...2G3 122 P2RA52G3 126 2 1 2 P2RAA52G3 122 Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 49...

Page 2: ...Y The Sta Rite P2R and P2RA Series Self priming Centrifugal pump Is designed for use with swimming pools or as a centrifugal pump Is an excellent performer durable reliable Table of Contents Safety In...

Page 3: ...y checks Check all clamps bolts lids and system accessories before testing Release all air in system before testing Tighten Sta Rite trap lids to 30 ft lbs 4 1 kg m torque for testing Water pressure f...

Page 4: ...E Use Teflon tape or Plasto Joint Stik1 for making all threaded connections to the pump Do not use pipe dope pipe dope will cause stress cracking in the pump NOTICE Pump suction and discharge connecti...

Page 5: ...l Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction 5 TABLE I RECOMMENDED FUSING AND WIRING DATA P2RA Series Motor Branch Fuse...

Page 6: ...size and type wire required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG or larger Run wire from external...

Page 7: ...will depend on vertical length of suc tion lift and horizontal length of suction piping If pump does not prime make sure that all valves are open suction pipe end is under water and that there are no...

Page 8: ...period Have a qualified serviceman repair wiring as needed 4 Inspect and tighten all watertight connections 5 Open all valves in suction and return piping 6 Remove any winterizing plugs in piping syst...

Page 9: ...leak 4 Remount seal plate to motor Tighten bolts to 60 80 inch lbs 69 92 cm kg torque 5 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 6 Slide rotating seal membe...

Page 10: ...impeller is not clogged follow steps 1 through 7 under Removing Old Seal Page 8 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 9 for reassembly 8 Impeller and dif...

Page 11: ...11 19 Washer Flat 2 U43 42SS 20 Screw 3 8 16 x 1 3 4 Hex Head 2 U30 77SS 21 Screw 3 8 16 x 1 Hex Head 2 U30 74SS Reducer 2 x 1 1 2 1 C78 7P Tag CAUTION This pump equipped 61002 0002 with mechanical sh...

Page 12: ...Pad 1 C35 11 19 Washer Flat 2 U43 42SS 20 Screw 3 8 16 x 1 3 4 Hex Head 2 U30 77SS 21 Screw 3 8 16 x 1 Hex Head 2 U30 74SS Reducer 2 x 1 1 2 1 C78 7P Tag CAUTION This pump equipped 61002 0002 with me...

Page 13: ...otherwise indicated Overhaul Kits Parts Pak Number H P P2R P2RA 1 2 PP1011 PP1010 3 4 PP1014 PP1011 1 PP1016 PP1014 1 1 2 PP1018 PP1016 2 PP1018 Kit includes Impeller Diffuser Shaft Seal Gaskets O Ri...

Page 14: ...ence misapplication improper installation or maintenance or other circum stances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Reviews: