3. Proper Use

2.3.2 Other Safety Components and 

 

Regulations

Work on electrical components must be carried 
out by a qualified electrician in accordance with 
accepted technical practices. 

The operating instructions provided by the motor 
manufacturer (if applicable) must be followed at 
all times.

The electrical equipment of the pump must be 
inspected and checked regularly. Faults such as 
loose connections or damaged cables must be 
corrected immediately.

The product is designed for the pumping of clear 
or slightly cloudy water in swimming pool 

 

applications. In case of other media or 
applications, the exact usage specification must 
be discussed with the manufacturer.

The product must only be used as specified in 
these instructions. Any other form of use 

 

constitutes improper use. In this case, the 
manufacturer accepts no liability for any resulting 
damages.

The product has been designed and constructed 
to the latest state of technology, and is 
completely safe and reliable if used in 
accordance with these operating instructions and 
any other specific system or operating 

 

requirements.

Nevertheless, their use may still give rise to 

 

danger to life and limb of the operator or other 
persons, or damage to the product or other 
equipment.

Modifications to the product is possible in certain 
cases. In such cases, advance, written approval 
must be obtained from the manufacturer.

The manufacturer accepts no responsibility in 
the following cases:

3.1 Improper Use

The product may cause dangers if used 
improperly or not for their intended purpose.

Under no circumstances must the pump be 
used for aggressive fluids, inflammable fluids, 
toxic fluids or other unapproved solutions.

Failure to observe the information in these 

 

operating instructions

Use of spare parts or components not 
approved by the manufacturer

Incorrect operation

Removal, modification or deactivation of safety 
devices

Improper performance of maintenance work

Improper use

4. Transport/Winterizing

The complete delivery should be checked 

 

immediately on arrival for completeness and any 
possible transport damage. Complaints will only 
be accepted if they are reported to the shipper or 
manufacturer on the day of delivery. 

4.1 Unpacking

The packaging materials should be reused if 
possible, or disposed of in accordance with local 
regulations.

4.2 Storage – Winterizing

Extended intermediate storage in an 
environment with high air humidity 
and changing temperatures should 
be avoided. Condensation ma 

damage the motor windings and 

 

other metallic parts. This will 
invalidate the guarantee.

The pump may also be damaged if 
exposed to frost. This will also 
invalidate the guarantee. Anti-freeze 
must not be used, since this can 

 

cause damage to plastic parts. 

In the event of risk of frost, the pump should be 
drained thoroughly. To do this, open the drain 
plug and allow water to drain out of the pump. 
Also tip the pump upside down to drain any 
additional water from discharge port of the pump. 
The piping system should also be emptied 

 

completely of water. 

4

Attention

Attention

Summary of Contents for Boost-Rite S4P100M

Page 1: ...ressure Side Cleaners or Water Boosting Applications For Models S4P100M S5P150M Pentair Water Belgium bvba Industriepark Wolfstee Toekomstlaan 30 B 2200 Herentals Belgium 32 0 14 25 99 11 www pentairp...

Page 2: ...he basis of their professional training skills and experience are able to assess the work in hand and recognize any possible dangers They are also aware of the applicable conditions These must be only...

Page 3: ...duced to a minimum The product must not be used for any other purpose than that specified by the manufacturer This may cause unforeseeable risks Local work and safety regulations and laws must be foll...

Page 4: ...ty in the following cases 3 1 Improper Use The product may cause dangers if used improperly or not for their intended purpose Under no circumstances must the pump be used for aggressive fluids inflamm...

Page 5: ...from the power supply with a contact opening gap for each pole of at least 3 mm The manufacturer accepts no liability for damage to the motor that can be prevented by the installation of an external...

Page 6: ...g is blocked Impeller is blocked by debris Air leak in suction line Motor rotation is incorrect Air leak in Suction line Debris in plumbing lines or pump housing Diameter of suction line is too small...

Page 7: ...Temperature Max Salt content in Water pH Range Max Operating Pressure Protection Type Insulation Class Revolutions per Minute RPM Max Noise Level Voltage s Phase s Inlet Outlet Thread 50C 50C 0 4 4 9...

Page 8: ...xperts sont d finis en tant que personnes qui sur la base de leur formation professionnelle comp tences et exp rience sont capables d valuer le travail et reconna tre les dangers possibles Ils sont ga...

Page 9: ...eut provoquer des risques impr visibles Les r glementations et lois locales sur la s curit au travail doivent tre suivies tout moment Ceci s applique aux r glementations sur l environnement Si un dang...

Page 10: ...Le produit peut provoquer des dangers s il est mal utilis ou pas dans l objet intentionnel En aucune circonstance la pompe ne doit tre utilis e pour des fluides agressifs inflammables toxiques ou aut...

Page 11: ...ation lectrique avec un espace d ouverture de contact pour chaque p le d au moins 3 mm Le fabricant n accepte aucune responsabilit pour les dommages qui peuvent tre emp ch s par l installation d un co...

Page 12: ...ble pression du filtre La plomberie d entr e est bloqu e La t te de pompe est bloqu e par des d bris Fuite d air dans la conduite d aspiration La rotation du moteur est incorrecte Pompe bruyante Fuite...

Page 13: ...eur maximale en sel dans l eau Gamme de pH Temp rature max de fonctionnement Type de protection Cat gorie d isolation Tours par minute tpm Niveau max de bruit Tension s Phase s Filetage entr e sortie...

Page 14: ...personas que bas ndose en su formaci n profesional habilidades y experiencia est n capacitados para evaluar el trabajo en cuesti n y reconocer cualquier posible peligro Tambi n son conscientes de las...

Page 15: ...por el fabricante Esto puede provocar riesgos imprevisibles Se deben cumplir en todo momento las regulaciones y leyes laborales y de seguridad locales Lo mismo aplica a las regulaciones medioambiental...

Page 16: ...ocar riesgos se se utiliza de forma incorrecta o para un uso distinto al pretendido Bajo ninguna circunstancia debe usar la bomba para fluidos agresivos inflamables t xicos u otras soluciones inapropi...

Page 17: ...de alimentaci n con un espacio de apertura de contacto para cada polo de al menos 3 mm El fabricante no acepta ninguna responsabilidad por los da os en el motor que puedan evitarse mediante la instal...

Page 18: ...st bloqueada El rotor est bloqueado por residuos Fuga de aire en la l nea de aspiraci n La rotaci n del motor es incorrecta Fuga de aire en la l nea de aspiraci n Residuos en las l neas de tuber as o...

Page 19: ...x contenido de sal en agua Rango del pH Presi n de funcionamiento m x Tipo de protecci n Clase de aislamiento Revoluciones por minuto RPM Nivel de ruido m x Tensiones Fases Roscado de entrada salida...

Page 20: ...iten und Erfahrung die anstehende Arbeit beurteilen und m gliche Gefahren erkennen k nnen Sie sind sich auch der geltenden Bedingungen bewusst Es d rfen nur ordnungsgem ausgebildete Fachkr fte oder an...

Page 21: ...dem durch den Hersteller spezifizierten verwendet werden Ansonsten k nnen unvorhersehbare Risiken auftreten Die lokalen Arbeits und Sicherheitsvorschriften und gesetze m ssen jederzeit befolgt werden...

Page 22: ...ab 3 1 Unsachgem er Gebrauch Dieses Produkt kann Gefahren verursachen wenn es unsachgem oder nicht f r seinen beabsichtigten Zweck verwendet wird Unter keinen Umst nden darf die Pumpe f r aggressive...

Page 23: ...mm f r jeden Pol installiert werden das eine Abschaltung vom Netzanschluss erm glicht Der Hersteller lehnt jede Haftung f r Motorsch den ab die durch die Installation eines externen Schutzschalters v...

Page 24: ...mpenrad ist durch Verunreinigungen blockiert Luftaustritt in der Saugleitung Motordrehung ist fehlerhaft Luftaustritt in der Saugleitung Verunreinigungen in Installationsleitungen oder Pumpengeh use D...

Page 25: ...ertemperatur Max Salzgehalt im Wasser pH Bereich Max Arbeitsdruck Schutzart Isolationsklasse Umdrehungen pro Minute UpM Max Ger uschpegel Spannung en Phase n Einlauf Auslaufgewinde 50 C 50 C 0 4 4 9 6...

Page 26: ...ienza in grado di valutare il lavoro svolto e di identificare eventuali pericoli oltre a conoscere le relative condizioni Questo gruppo comprende esclusivamente specialisti addestrati o altro personal...

Page 27: ...si possono produrre rischi imprevisti Le leggi ed i regolamenti nazionali in vigore in materia di sicurezza devono essere rispettati Lo stesso si applica per le leggi in materia ambientale Se si risco...

Page 28: ...ove utilizzato non correttamente o per il suo reale uso pu creare pericolo La pompa non deve in alcuna circostanza essere utilizzata per fluidi aggressivi per fluidi infiammabili per fluidi tossici o...

Page 29: ...tallato un separatore che permetta lo scollegamento dall alimentazione dell acqua con un foro di contatto di almeno 3 mm per ciascun polo Il produttore non accetta responsabilit per danni al motore ch...

Page 30: ...bloccati Rotore bloccato da detrtiti Perdita d aria nella linea di aspirazione Errata rotazione del motore Perdita d aria nella linea di aspirazione Detriti nei tubi o nell alloggio della pompa Diamet...

Page 31: ...acqua Contenuto salino max acqua Valori PH Pressione operativa max Tipo di protezione Classe di isolamento Giri al minuto G min Livello max rumore Voltaggio i Fase i Thread Entrata Uscita 50C 50C 0 4...

Page 32: ...heden en ervaring in staat zijn om het uit te voeren werk op zijn waarde in te schatten en eventuele gevaren te herkennen Zij zijn zich ook bewust van de geschikte omstandigheden Dit zijn goed getrain...

Page 33: ...oor andere doeleinden dan die gespecificeerd door de fabrikant Dit kan onvoorziene risico s tot gevolg hebben De plaatselijke werkverordeningen veiligheidsvoorschriften en regelgevingen moeten te alle...

Page 34: ...olgende gevallen 3 1 Onjuist gebruik Het product kan gevaar opleveren indien onjuist gebruikt of anders is aangewend dan voor het doel waarvoor het is ontworpen Onder geen voorwaarde mag de pomp gebru...

Page 35: ...ing voor iedere pool van tenminste 3 mm de stroomtoevoer afsluit De fabrikant is niet aansprakelijk voor schade aan de motor die vermeden kan worden door de installatie van een externe beschermingssch...

Page 36: ...r vuil Luchtlek in de aanzuiglijn De motorrotatie is niet goed Luchtlek in de aanzuiglijn Vuil in de afvoerlijn of de behuizing van de pomp Diameter van de aanzuiglijn is te klein Pomp onjuist ge nsta...

Page 37: ...eratuur Max zoutgehalte van het water pH gehalte Max werktemperatuur Soort bescherming Isolatieniveau Omwentelingen per minuur Max geluidsniveau Voltage s Fase s Schroefdraad inlaat uitlaat 50C 50C 0...

Page 38: ...38...

Page 39: ...39...

Page 40: ...253P7920 Rev A Pentair Water Belgium bvba Industriepark Wolfstee Toekomstlaan 30 B 2200 Herentals Belgium 32 0 14 25 99 11 www pentairpooleurope com a Company...

Reviews: