How to control the RF and I²C channels from your screen
UM0853
30/49
Doc ID 16609 Rev 1
Figure 64.
Result of a Read operation to the memory array
Figure 64
illustrates the result of the Read operation to the memory array. The first column
shows which sector is read. The second column indicates the address of the first byte in the
page. Then the third column gives the data.
Let us take the example corresponding to the data < 69 87 04 00 >
69 (69h Hex) is data for address 0028h (sector 0)
87 (87h Hex) is data for address 0029h (sector 0)
04 (04h Hex) is data for address 002Ah (sector 0)
00 (00h Hex) is data for address 002Bh (sector 0)
Reading the sector security status
To read all the sector security status bytes (RF block security), select
Sector Security
Status (system)
then press the
Read
button.
Figure 65
shows how to launch an operation to read the sector security status.
Figure 65.
Reading the sector security status