7
System
If the sensor element is not in use currency will flow from connection 3 to connection 5
as well as from connection 4 to connection 6. This leads the relay K1 and K2 to close their
contact and therefore activate the output.
To obtain a secure output signal the contacts of relay K1 and K2 have to be switched in
sequence.
If the sensor element is activated the currency ratios at sensor inlets 5 and 6 of the controller
change.
This change causes the relays to switch off and the output contacts are opened. A short
circuit has the same effect on the transducer connection cable.
If a wire or a conductive stretch of the sensor element is cut, at least one relay is switched off.
Due to the sequence switching of the relay contacts a cut-off of the electric circuit is ensured.
The transducer connections are marked and colour coded.
The following table shows which colours are assigned to which connections.
Activated sensor element
3
4
5
6
K1
K2
13
14
33
34
4-wire cable
Label
Rails Bumpers Mats
3
GREEN BLUE
4
BROWN BROWN
5
YELLOW BLACK
6
WHITE WHITE
two 2-wire cable
Label
Colour
3
BROWN
4
WHITE
5
BROWN
6
WHITE
Summary of Contents for SSZ-BAT
Page 1: ...1 Sicherheits Systeme Zimmermann GmbH system manual...
Page 5: ...5 41 System...
Page 10: ...10 41 Controllers...
Page 36: ...36 41 Safety mats...
Page 41: ...41 Safety rails...
Page 45: ...45 Safety bumpers...
Page 49: ...49 Annex...
Page 54: ...54 Annex 3 4 5 6 SSZ control unit Sequential wiring of various transducers...
Page 59: ...59 Annex...
Page 62: ...62 Notes...
Page 63: ...63 Notes...
Page 64: ...64 Notes...