Function test
The safety rail can be tested with a multimeter or a gauge. For a function test the safetyrail
must be disconnected from the controller and all further safety components.
The test areas and results are in the following table.
The test results from wire 3/ 5 and wire 4/ 6 are not the same however, the difference may
not exceed 20%!
To test the controller, please see the chapter about controllers.
Sequential wiring of safety rails
Testleads to wires
Meter range
Test result
3 and 4 wires 5 and 6 open
20 MOhm
∞
3 and 4 wires 5 and 6 linked
400 KOhm
<280 KOhm
3 and 5
200 KOhm
<140 KOhm
4 and 6
200 KOhm
<140 KOhm