39
Safety mats
3 4 5
6
SSZ-control unit
If the safety mat is activated the controller‘s relay contacts open and the dangerous
movement is stopped.
If more than one safetymat has to be attached to the controller these have to be wired in
sequence.
For further information about sequence switching, please see the connection examples in
the annex.
After the device has been installed and before starting the machine every time thecorrect
functioning of the safety device must be checked.
Function test
The safety mat can be testedwith a multimeter or gauge.
To do a function test the mat has to be disconnected from the controller and further safety
components.
The test areas and results are in the following table.
Testleads to wires
Meter range
Test result
3 and 4 wires 5 and 6 open
20 MOhm
∞
3 and 4 wires 5 and 6 linked
400 KOhm
<280 KOhm
3 and 5
200 KOhm
<140 KOhm
4 and 6
200 KOhm
<140 KOhm
The test results from wire 3/ 5 and wire 4/ 6 are not the same however, the difference may
not exceed 20%!
To test the controller, please see the chapter about controllers.
Sequential wiring of safety mats
Summary of Contents for SSZ-BAT
Page 1: ...1 Sicherheits Systeme Zimmermann GmbH system manual...
Page 5: ...5 41 System...
Page 10: ...10 41 Controllers...
Page 36: ...36 41 Safety mats...
Page 41: ...41 Safety rails...
Page 45: ...45 Safety bumpers...
Page 49: ...49 Annex...
Page 54: ...54 Annex 3 4 5 6 SSZ control unit Sequential wiring of various transducers...
Page 59: ...59 Annex...
Page 62: ...62 Notes...
Page 63: ...63 Notes...
Page 64: ...64 Notes...