INSTRUCTIONS

CONTROLLER ASSEMBLY 

(CONTINUED)

DO NOT PROCEED to the next step until the solenoid valve and pressurized piping loop have 

been completely installed to your tank.

5. Run the 15ft M12 Power Cable from the Controller box to the power supply. Connect via the M12 

connectors. Do not connect the power supply to power until setup is complete.

6. Wrap Hook and Loop Straps around wiring to keep cables neat.

The FTSs Pro Touch temperature controller comes with a 10ft cable with no 

connector on the end. The wire in this cable will connect to your 3 wire PT100 

temperature sensor. If you are using an Ss Brewtech vessel, your tank comes 

equipped with a PT100 platinum resistance thermometer. The dark red wire 

connects to terminal 1, the light red connects to terminal 2 and the blue wire 

connects to terminal 3 on the thermometer’s plug.

SENSOR INSTALLATION

The FTSs Pro Touch temperature controller is designed to 

operate with either a ½” (1-3.5 bbl Unitank) or ¾” (5 bbl and 

larger Unitank) electric solenoid valve connected using a M12 

connector. Installation can be handled in a variety of ways 

based on preference and setup. We recommend installation of 

a manual bypass piping/valve arrangement, as well as piping/

valve arrangement to clear the line of glycol in the event that 

service is needed.

SOLENOID INSTALLATION

24VDC via 

a 110 VAC 

power supply

1

2

3

Summary of Contents for FTSs Pro Touch

Page 1: ...Page 1 ENGINEERING BETTER BEER FTSs Pro Touch Product Guide ...

Page 2: ...ONENTS SOLD SEPARATELY Solenoid Valve 24VDC with M12 in NPT for Nano Jacketed Tanks 1bbl 3 5bbl OR Solenoid Valve 24VDC with M12 in NPT for Pro Jacketed Tanks 5bbl 3 wire PT100 temperature probe Included on Ss Brewtech Jacketed Tanks FTSs Pro Touch Power Supply 10 A 24VDC with M12 One FTSs Pro Touch Power Supply 10 A 10A power supply can power up to three FTSs Pro Touch setups with the use of the ...

Page 3: ...will open to allow the flow of glycol through your vessel s cooling jacket s until the set temperature is achieved CONTROLLER ASSEMBLY 1 Remove components from packaging 2a Install 1 5 Pipe Clamp Insert to the FTSs Pro Touch on your tank s Blow Off Arm 2b Optional Install 1 Pipe Clamp Reducer for tanks that have a 1 Blow Off Arm 3 Connect the PT100 Temp Probe to 10ft Temperature Probe Wire see SEN...

Page 4: ...re sensor If you are using an Ss Brewtech vessel your tank comes equipped with a PT100 platinum resistance thermometer The dark red wire connects to terminal 1 the light red connects to terminal 2 and the blue wire connects to terminal 3 on the thermometer s plug SENSOR INSTALLATION The FTSs Pro Touch temperature controller is designed to operate with either a 1 3 5 bbl Unitank or 5 bbl and larger...

Page 5: ...ss the digit on the right and adjust it to match your vessel 3 To set an identifying number for the vessel press the digit next to NUMBER and select the number of your choice Note we suggest starting with 1 for your first vessel and increasing to match the total amount of tanks For example if you have three 10 bbl fermenters the first tank would be named FV10 1 and the remaining two would be FV10 ...

Page 6: ... to cold crash your beer This will drop your current temperature down to a low user programmable temperature in order to drop out the yeast biomass and other cold break particulates We have included a separate temperature setting specifically for this purpose The FERMENT and CRASH modes both contain preset temperatures and the rotary switch allows the user to quickly and conveniently switch betwee...

Page 7: ... the side of the FTSs Pro Touch 2 If the USB is installed and nothing happened ensure the USB has the correct FAT 32 formatting 3 If neither of these work please contact our technical support team for assistance 4 Select the Return Arrow on the DATA EXPORT Screen 5 To reset the graph data press RESTART GRAPH from Settings Screen to clear the previous data log OPERATING INSTRUCTIONS CONTINUED VIEWI...

Page 8: ...nsors will have the same calibrations offset so this process should be performed on each sensor 1 Determine how many degrees you need to adjust the controller up to 12 0 degrees either way This can be determined with a thermowell and an ice bath as described above 2 Select Settings Cog on the Start Up Screen or on the main Temp Control Screen 3 Select CALIBRATE to bring up the Temp Calibration Scr...

Page 9: ...e Start Up Screen or on the main Temp Control Screen 2 Select and hold RESET GRAPH for 5 seconds Your screen will blink and factory reset your controller This will bring you to the initial setup process including Vessel Name Screen and the First Time Setup Screen FERMENT OFF CRASH ...

Page 10: ...REV 10072022 SsBrewtech com ...