Page 4
INSTRUCTIONS
CONTROLLER ASSEMBLY
(CONTINUED)
DO NOT PROCEED to the next step until the solenoid valve and pressurized piping loop have
been completely installed to your tank.
5. Run the 15ft M12 Power Cable from the Controller box to the power supply. Connect via the M12
connectors. Do not connect the power supply to power until setup is complete.
6. Wrap Hook and Loop Straps around wiring to keep cables neat.
The FTSs Pro Touch temperature controller comes with a 10ft cable with no
connector on the end. The wire in this cable will connect to your 3 wire PT100
temperature sensor. If you are using an Ss Brewtech vessel, your tank comes
equipped with a PT100 platinum resistance thermometer. The dark red wire
connects to terminal 1, the light red connects to terminal 2 and the blue wire
connects to terminal 3 on the thermometer’s plug.
SENSOR INSTALLATION
The FTSs Pro Touch temperature controller is designed to
operate with either a ½” (1-3.5 bbl Unitank) or ¾” (5 bbl and
larger Unitank) electric solenoid valve connected using a M12
connector. Installation can be handled in a variety of ways
based on preference and setup. We recommend installation of
a manual bypass piping/valve arrangement, as well as piping/
valve arrangement to clear the line of glycol in the event that
service is needed.
SOLENOID INSTALLATION
24VDC via
a 110 VAC
power supply
1
2
3