OVERVIEW
SYSTEM OVERVIEW
The FTSs Pro Touch Temperature Controller works in conjunction with a pressurized glycol loop
system to provide temperature control over the contents of your vessel. It functions by using a
temperature sensor to read the current temperature of your vessel, and triggering an output based on
the set temperature in order to compensate. When cooling is called for, the solenoid valve will open to
allow the flow of glycol through your vessel’s cooling jacket (s) until the set temperature is achieved.
CONTROLLER ASSEMBLY
1. Remove components from packaging.
2a. Install 1.5” Pipe Clamp Insert to the FTSs Pro Touch on your tank’s Blow Off Arm
2b. (Optional) Install 1” Pipe Clamp Reducer for tanks that have a 1” Blow Off Arm
3. Connect the PT100 Temp Probe to 10ft Temperature Probe Wire (see SENSOR INSTALLATION
section).
4. Run the wire from the FTSs Pro Touch to the installed solenoid valve set up. Connect via M12
connectors.
Install on 1.5” Pipe with 1.5” Clamp Insert
Install on 1” Pipe with 1.0” Clamp Insert