Installation and Operation
Waukesha Cherry-Burrell
Page 14
95-03083
April 2008
Figure 17: AS-I Eurofast Wiring
Solenoid 1
Solenoid 2
Solenoid 3
Top Port Location
When plugging use
1/8-27 NPT Pipe Plug (P/N 78-73)
Optional PMO Yoke Prox Switch
Route wire through Port 4 and Top
Use 0, 1, 2, or 3 Solenoids
as required on assembly
Vent Plug
4 Pin Connector
Cut back and tape
White (Pin 2) and
Black (Pin 4) wires
Ref. P/N 113600
Solenoid 3
Solenoid 1
Brown
(Pin Connector)
Blue
(Pin Connector)
Solenoid 2
Brown (Sensor)
Black (Sensor)
Brown (PMO Yoke Prox)
Blue (PMO Yoke Prox)
Gray (Sensor)
Blue (Sensor)
White (Sensor)
Pin 2
White
Not Used
Pin 3
Blue
AS-I (-)
Pin 4
Black
Not Used
Pin 1
Brown
AS-I (+)
E70217
Valve Top Module 4Di/4DO T ST
Ifm efector inc.
Exton, PA 19341 800-441-8246
24V DC
200mA
VA100-571
Figure 18: DeviceNet Eurofast Wiring, Single-Seat
USE 0, 1, 2, OR 3 SOLENOIDS
AS SPECIFIED ON BILL OF MATERIAL.
SOLENOID
LOCATION 1
SOLENOID
LOCATION 2
SOLENOID
LOCATION 3
5 PIN CONNECTOR
REF. P/N 115761
VENT PLUG
REFERENCE VIEW OF 5 PIN CONNECTOR
OPTIONAL:
ROUTE PMO YOKE PROX SWITCH
WIRE THROUGH AT PORT 4 AND
TOP PORT.
PIN 2
RED
+ 24 VDC
PIN 1
GRAY
SHEILD
PIN 4
WHITE
CAN_H
PIN 3
BLACK
- 24 VDC
PIN 5
BLUE
CAN_L
BLACK (PIN 3 CONNECTOR)
BLUE (PIN 5 CONNECTOR)
GRAY (PIN 1 CONNECTOR)
WHITE (PIN 4 CONNECTOR)
RED (PIN 2 CONNECTOR)
V + ; BROWN (SENSOR),
BROWN (PMO YOKE PROX)
I3; BLACK (PMO SWITCH)
I2; BLACK (SENSOR)
I1; WHITE (SENSOR)
I0; GRAY (SENSOR)
O3; NOT USED
O2; BLACK (SOLENOID 3)
O1; BLACK (SOLENOID 2)
O0; BLACK (SOLENOIL 1)
V - ; BLUE (SENSOR),
BLACK (SOLENOID 1),
BLACK (SOLENOID 2),
BLACK (SOLENOID 3),
BLUE (PMO YOKE SWITCH)
1X ADDRESS TO BE: 3
10X ADDRESS TO BE: 6
NOTE: USE 120258 TERMINAL FOR V-
VA100-572