background image

English

Original instructions

AquaT

 

Silent Electric marine toilet- Instruction manual 

Whenever your craft is unattended, even if only for a very short period of 

time, both seacocks (even if secondary valves are fitted) MUST be shut.

Ensure that ALL users understand how to operate the toilet system cor-

rectly and safely, including seacocks and secondary valves.

Take special care to instruct children, the elderly and visitors

Absolutely shut seacocks!

Using the toilet

Control panel

The panel controls the rinse and the discharge, by two buttons.

• Button 1, One function, discharge and rinse.

• Button 2, Two functions, Rinse toilet OR discharge toilet.

First use

1. Open inlet and outlet seacocks (and secondary valves if fitted)

2. Use control panel as described above.

3. Do not put anything in the toilet unless it has not pasted through

your body, except toilet paper.

Normal Use

Open inlet and outlet seacocks (and secondary valves if fitted).

1. Before use, ensure that there is enough water in the bowl to prevent

the toilet paper becoming compacted at the bottom of the bowl.

2. If the bowl is empty, flush the toilet with button 2 “Flush".

3. Use good quality soft household toilet paper, but do not use more

than necessary.

4. After use, flush the toilet with button 1.

Afterwards, flush the toilet until the bowl is empty, Always leave the bowl 

empty to minimize odour and spillage

After use:

• Shut both seacocks

NOTE: Do not put any of the following into the toilet: Sanitary Towels, 
Wet Strength Tissues, Cotton Wool, Cigarettes, Matches, Chewing 
Gum or any solid objects, Petrol, Diesel, Oil, Solvents of any kind or 
water more than hand warm.

Cleaning

A regular flushing with clean (sea)-water represents one of the most effec-

tive methods to keep the toilet clean and good smelling.

• To clean the bowl, use any liquid or cream ceramic cleaner

• To clean the rest of the toilet, including the seat and lid, use a non-

  abrasive liquid cleaner Polish with a dry cloth only.

• To disinfect the toilet, use a liquid disinfectant diluted in accordance

with the manufacturer's instructions. It is possible to apply it to all

parts of the toilet using a sponge or soft brush as necessary.

• After applying any cleaning or disinfecting agent, always flush well.

DO NOT ALLOW THESE AGENTS TO STAND IN THE SYSTEM.

CAUTION:
• Do not use abrasive pads on any part of the toilet and do not use

cream cleaners except for the bowl.

• Do not use thick liquid toilet cleansers or neat bleach because they

may damage the valves, gaskets and seals.

Maintenance instructions

Introduction

SPX FLOW Johnson Pump AquaT Silent Electric marine toilets normally do 

not require maintenance during the season, provided that they are winter-

ized in the autumn and overhauled in the spring.

However, any toilet will benefit from:

Thorough flushing (refer to the operating instructions for normal use).

HAZARD RISK LEAKS:

 If the toilet is connected to any through-hull fit-

tings, and if the toilet or the pipework develops a minor leak, this leak can 

suddenly become a bigger leak which will allow water to flood in, causing 

the craft to sink, with subsequent loss of property and life.

Therefore, in case any leak develops, repair it immediately! Moreover, regu-

larly inspect all fastenings to check tightness and leaks.

Service
Preparation for winterization

SPX FLOW Johnson Pump AquaT Silent Electric marine toilets marine 

toilets are design to be simple to service; therefore no special skills are 

needed, as well as no special tools are required.

• Flush the toilet according to the operating instructions for normal

use and particularly ensure that all waste has left the discharge

pipework, that the bowl is empty and that both seacocks are closed

(even though secondary valves are fitted)

• Mop-up any water which might come out of the system

Winterization

Drain the complete system both as a protection against frost damage and 

to avoid the growth in the pipework of bacteria that could cause unpleas-

ant smells. Make sure that the discharge pump as well as the rinse pump is 

empty from water because of the risk of freezing during the winter.

HAZARD RISK:

 

Seacocks opened by mistake.

 In case you leave the toilet disassembled 

and if the sea cocks are opened when the boat is afloat, water will flood in 

by causing the sinking of the boat and the possible loss of life. Therefore, it 

is indispensable to attach a warning notice to the seacocks and, if possible, 

wire the seacocks shut.

Remember to attach warning notices!

WARNING: 
The use of anti-freeze is not recommended

, as it is not possible to en-

sure that the product penetrates the whole toilet system If, for any reason, 

an anti-freeze compound is employed it will have to be a glycol based one.

• Open any secondary valve.

• Loosen hose clips and disconnect all the hose ends from the sea

cock hose tails, the hose toilet tails, and any secondary valves.

• Use button 1 to drain the toilet pump and ensure that all water is

properly drained from the toilet system.

• Reconnect all hose ends and secure them with their hose clips.

Button 1

Button 2

Wire size per feet and meter of run

Voltage Fuse 

size

0'-10'

10'-15'

15'-25'

25'-40'

40'-60'

0m-3m

3m-4,6m 4,6m-7,6m

7,6m-12,2m 12,2m-18,3m

12V

25A

#14

#14

#12

#10

#8

2,5 mm

2

2,5 mm

2

4 mm

2

6 mm

2

10 mm

2

24V

20A

#14

#14

#14

#14

#12

2,5 mm

2

2,5 mm

2

2,5 mm

2

2,5 mm

2

4 mm

2

6

Summary of Contents for Johnson Pump AquaT Silent Electric Comfort

Page 1: ...OF OR IG I NAL I N STR UCTION S R EAD AN D U N DE RSTAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PRODUCT AquaT Marine Toilet S I LE NT E LECTR IC Compact Comfort I B 412 2 R06 05...

Page 2: ...ur ckgeschickt werden FR Garantie Les produits sont garantis deux 2 ans Aucune garantie ne sera accept e dans les cas suivants si la cuvette est cass e si les instructions de montage concernant le sys...

Page 3: ...ipework from 4 possibilities accord ing to whether the toilet is above or below the waterline and to whether it discharges the waste overboard or into an on board holding tank General instructions for...

Page 4: ...without risk of it being siphoned away Alternative 3 Toilet waste discharging into holding tank discharge elbow below top of holding tank at any time 20 cm 8 Fig 3 Toilet waste discharging into holdi...

Page 5: ...iphon Location The mounting surface must be flat rigid and strong enough to sup port a man s weight and should be at least 50 mm 2 wider and 50 mm 2 deeper than the base of the toilet You will need su...

Page 6: ...cleansers or neat bleach because they may damage the valves gaskets and seals Maintenance instructions Introduction SPX FLOW Johnson Pump AquaT Silent Electric marine toilets normally do not require...

Page 7: ...n the base as a guide mark the positions for the 3 bolt holes on the mounting surface Remove the toilet and drill 3 vertical holes with a diameter of 9 mm through the mounting surface 2 Apply the whit...

Page 8: ...02 4a Intake elbow 81 47640 01 4b Intake elbow 81 47246 01 4c Intake elbow Premium 81 47246 03 5 Bowl gasket 81 47274 01 7 Base group 81 47247 01 8 Motor group 12V 81 47248 01 Motor group 24V 81 4724...

Page 9: ...are per quanto concerne i materiali e i metodi di installazione Assicuratevi che la valvola di presa dell acqua di mare di entrata sia posizionata in modo da trovarsi sempre al di sotto della linea di...

Page 10: ...punto di entrata della pompa di flusso della toilette si trovi a pi di 2 m 6 sopra la linea di galleggiamento effettiva quando l imbarcazione in moto necessario installare una valvola antiri torno vi...

Page 11: ...mare a passaggio integrale a tali dispositivi per lo scafo al fine di consentirne la chiusura Le valvole di mare devono inoltre essere collocate in luoghi facilmente accessibili a tutti gli utilizzat...

Page 12: ...QUALSIASI dispositivo passante per lo scafo che possa trovarsi sotto la linea di galleggiamento in qualsiasi momento e se la toilette o le tubature sono danneggiate potrebbe venire imbarcata dell acqu...

Page 13: ...dalle istruzioni di funziona mento per il normale utilizzo in particolare assicuratevi che tutti i rifiuti siano stati espulsi dalle tubature di scarico che il vaso sia vuoto e che entrambe le valvole...

Page 14: ...Utilizzando la base come riferimento segnate la posizione dei 3 fori per i bulloni sulla superficie di montaggio Rimuovete la toilette e praticate 3 fori verticali con un diametro di 9mm nella superfi...

Page 15: ...i aspirazione 81 47640 01 4b Gomito di aspirazione 81 47246 01 4c Gomito di aspirazione Premium 81 47246 03 5 Guarnizione del vaso 81 47274 01 7 Gruppo della base 81 47247 01 8 Gruppo motore 12V 81 47...

Page 16: ...English 16 Original instructions AquaT Silent Electric marine toilet Instruction manual Alt 1 Rinse Pump Black Red Blue Brown Fuse Discharge Pump Panel Red Yellow Brown Rinse Valve Alt 2 1 2...

Page 17: ...al instructions AquaT Silent Electric marine toilet Instruction manual 45 1 3 4 45 1 3 4 Drill 4 appropriate sized holes for the fasteners selected to secure the switch panel to its mounting surface N...

Page 18: ...glish 18 Original instructions AquaT Silent Electric marine toilet Instruction manual AquaT Silent Electric Compact Marine Toilet Including Control Panel and Flush 3 5 Pump AquaT Silent Electric Compa...

Page 19: ...glish 19 Original instructions AquaT Silent Electric marine toilet Instruction manual Including Control Panel and Flush 3 5 Pump AquaT Silent Electric Comfort Marine Toilet AquaT Silent Electric Comfo...

Page 20: ...certifications and local representatives visit Johnson Pump Marine at www spxflow com SPX FLOW Inc reserves the right to incorporate our latest design and material changes without notice or obligation...

Reviews: