Exhaust Hose Installation

The exhaust hose and adaptor must be installed or removed
in accordance with the usage mode:

COOL mode = install

FAN / DRY mode = remove

1. Attach both adaptors A and B to the exhaust hose. Extend
    each end of the hose by couple inches and turn the adaptor
    as shown in Fig 14. Do not over-tighten. Refer to previous
    page for window kit installation.
2. Align Adaptor A to the air outlet opening and push 
    along the arrow direction as in  Fig 15.
  

Through-the-Wall Installation

The exhaust hose can be installed through the wall. 

It is necessary to purchase the following parts:

Wall Adaptor
(sold separately, please contact
Sunpentown at 1-800-330-0388
or visit www.spt-usa.com)

Screws and expansion plugs
(can be purchased at any hardware
store)

1. Prepare a hole in the wall and install the Wall Adaptor to
    the opening (from outside). Secure with 4 expansion plugs
    and screws. Fig.16.
2. Attached exhaust hose to the Wall Adaptor.

Cover the hole using the adaptor cap when not in use.

IMPORTANT:

DO NOT OVER BEND THE EXHAUST HOSE

The exhaust hose can be compressed or extended moderately 
according to the installation requirement, but it is desirable to
keep the hose length to a minimum.

CAUTION:

Make sure there are no obstacles blocking the air outlet of the
exhaust hose (in the range of 20 inches), for the exhaust
system to work properly.

OPERATING  INSTRUCTIONS  -  CONTROL  PANEL

Before you begin, thoroughly familiarize yourself with the control panel and remote controller 
and all its functions, then follow the symbol for the functions you desire. 

Note: Some of the unit’s functions can only be controlled by the remote controller. 

ELECTRONIC CONTROL - OPERATING INSTRUCTIONS

OPERATION PANEL OF THE AIR CONDITIONER

Selects the appropriate operating mode. Each
press of the button will select mode in the
following sequence: COOL, FAN and DRY. The
corresponding mode indicator will illuminate.

NOTE: Fan speed cannot be changed or set on

speed). Fan speed can only be set or changed by
the remote controller for COOL and FAN modes.

UP ( + ) and DOWN ( - ) button

2

2

1

1

MODE

 

select button

         Power switch, press to turn on/off.

ON-OFF button

4

4

Displays set temperature under COOL mode.
Displays room temperature under DRY and
FAN modes.

LED Display

E2-  

Evaporator temperature sensor error- 

        Unplug the unit and plug it back in.
        If error repeats, call for service.

E4-  

Display panel

 

communication error- 

        Unplug the unit and plug it back in.
        If error repeats, call for service.

Error codes:
E1-  

Room temperature sensor error.

        Unplug the unit and plug it back in.
        If error repeats, call for service.

Protection codes:
P1-  

Bottom tray is full - connect drain hose

 

 

        to the drain outlet to empty the bottom tray.

 

        If code repeats, call for service.

         Used to increase or decrease temperature setting
         in 1°C or 1°F increments.
         Adjustable range: 62°F to 86°F (17°C to 30°C)

         
         

          

          
      
        

    
   NOTE: The control is capable of displaying 
    temperature in Fahrenheit or Celsius. To convert
    from one to the other, press and hold the UP 

    and Down buttons simultaneously for 3 seconds.

Fig.18

1

1

2

2

3

3

3

3

4

4

2

2

         Power indicator 
         light

         Timer indicator light
         (set only by remote controller)

the control panel (unit will operate under auto-fan

Fig.14

Fig.15

Fig.16

Fig.17

Summary of Contents for WA-8088E

Page 1: ...properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions care...

Page 2: ...by authorized personnel only Installation work must be performed in accordance with the national wiring standards by authorized personnel only CAUTION Read This Manual CONTENTS The rating data indica...

Page 3: ...t use this product for functions other than those described in this instruction manual Never do this Safety rules Dispose packaging materials such as plastic and carton in the appropriate waste bins W...

Page 4: ...the room cool and keep the heat out Adaptor A connects unit to hose Adaptor B connects hose to slider kit Exhaust Hose Window Slider Kit and Bolt Wall adaptor for through the wall installation not in...

Page 5: ...irements Window slider kit can be xed with a bolt Fig 5a Window Slider Kit Minimum 26 5in 2 22ft Maxmum 48 in 4 04ft Window Slider Kit Minimum 26 5 in 2 22ft Maxmum 48 in 4 04ft 6 7 INSTALLATION INSTR...

Page 6: ...nd all its functions then follow the symbol for the functions you desire Note Some of the unit s functions can only be controlled by the remote controller ELECTRONIC CONTROL OPERATING INSTRUCTIONS OPE...

Page 7: ...Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the unit is exposed to direct sunlight the air conditioner may not respond Close curtains blinds to bl...

Page 8: ...cessed Reset button is pressed all current settings will be cancelled and the controller will be reset to default 5 SLEEP Button Press to activate or disable Sleep function Select this function during...

Page 9: ...Off check the Timer indicator on the display panel is illuminated To Cancel press the CANCEL button will remove all timer settings To change setting repeat steps 1 to 3 OPERATING INSTRUCTIONS REMOTE...

Page 10: ...er a tap or spray with water hose May cause electrical danger If the power cord is damaged it should be repaired by manufacturer or certi ed electrician Air Filters Clean the lters at least once every...

Page 11: ...f purchase must be presented to Sunpentown s nominated representative The warranty will be void if the product if modi ed misused or repaired by an unauthorized person The warranty after repair will n...

Reviews: