SPT WA-8088E Owner'S Manual Download Page 3

2

3

SOCIABLE  REMARK

DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of 
such waste separately for special treatment is necessary.

Wild disposal of waste in forests and landscapes endangers your health when 
hazardous substances leak into the ground-water and nd their way into the food chain. 

To prevent injury to the user or other people and property damage, the following  instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage. 

   Your air conditioner should be used in such a way 
    that it is protected from moisture. e.g. condensation, 
   splashed water, etc. Do not place or store your air 
   conditioner where it can fall or be pulled into water 
   or any other liquid. Unplug immediately if it occurs.
   Always transport your air conditioner in a vertical 
   position and stand on a stable, level surface during 
   use. 
   Turn off the product when not in use.
   Always contact a qualied person to carry out 
   repairs. If the supply cord is damaged, it must be 
   replaced with a new power supply cord obtained 
   from the product manufacturer and not repaired.
   Keep a clearance of at least 12 inches all around 
   unit for proper air ow.
   If the air conditioner is knocked over during use, 
   turn off the unit and unplug immediately.

SAFETY  PRECAUTIONS

!

Always do this

   Do not operate your air conditioner in a wet room
   such as a bathroom or laundry room.
   Do not touch the unit with wet or damp hands or 
   when barefoot.
   Do not press the buttons on the control panel with
   anything other than your ngers.
   Do not remove any xed covers. Never use this 
   appliance if it is not working properly, or if it has
   been dropped or damaged.
   Never use the plug to start and stop the unit. 
   Do not cover or obstruct the inlet or outlet grilles.
   Do not use hazardous chemicals to clean or come
   into contact with the unit. Do not use the unit in the
   presence of inammable substances or vapour such
   as alcohol, insecticides, petrol, etc.
   Do not allow children to operate the unit 
   unsupervised.
   Do not use this product for functions other than
   those described in this instruction manual.

Never do this

Safety rules

Dispose packaging materials, such as plastic and carton, in the 
appropriate waste bins.

When this product reaches the end of its useful life, do not dispose with 
general household waste. For the correct collection and treatment of this
product, take them to the collection point for reuse of electrical and 
electronic equipment. Contact your local authority for the appropriate 
collection point in you neighborhood.

SPECIFICATIONS

Cooling capacity

EER

Power consumption

Power supply

Starting current

Compressor type

Air volume (High)

Noise level: Indoor/Outdoor (High)

Refrigerant type

Design pressure

Moisture removal capacity

Power cord length / Plug type

Operating temperature

Recommended room size

Unit dimension

Package dimension

Net/Gross weight

8,000 BTU

8.9

890W / 8A

115V / 60Hz / 1 PH

32A

Rotary

355 m3/h / 209 CFM

56/61 dB

R410A / 8.47 oz

550/340 PSIG

0.9 L/h

6.5 ft / 14#x3/LCDI

62°F to 95°F

150-250 sq. ft.

13.6W x 14D x 27.7H inches

14.8 x 15.8 x 34.5 inches

50.7 / 59.5

To prolong the life of the compressor, after powering
off the unit, wait at least 3 minutes before turning
the unit back on.

Be sure the electrical service is adequate for the model you have chosen. This information can be found 
on the serial plate, which is  located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and re hazards, proper grounding is 
important. The power cord is equipped with a three-prong grounding plug for protection against shock 
hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend
to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualied 
electrician install the proper receptacle. 
Ensure the receptacle is accessible after the unit installation.

For your safety

Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other 
appliance.
Avoid re hazard or electric shock. Do not use an  extension cord or an adaptor plug. Do not remove 
any prong from the power cord.

WARNING

Electrical Information

Summary of Contents for WA-8088E

Page 1: ...properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions care...

Page 2: ...by authorized personnel only Installation work must be performed in accordance with the national wiring standards by authorized personnel only CAUTION Read This Manual CONTENTS The rating data indica...

Page 3: ...t use this product for functions other than those described in this instruction manual Never do this Safety rules Dispose packaging materials such as plastic and carton in the appropriate waste bins W...

Page 4: ...the room cool and keep the heat out Adaptor A connects unit to hose Adaptor B connects hose to slider kit Exhaust Hose Window Slider Kit and Bolt Wall adaptor for through the wall installation not in...

Page 5: ...irements Window slider kit can be xed with a bolt Fig 5a Window Slider Kit Minimum 26 5in 2 22ft Maxmum 48 in 4 04ft Window Slider Kit Minimum 26 5 in 2 22ft Maxmum 48 in 4 04ft 6 7 INSTALLATION INSTR...

Page 6: ...nd all its functions then follow the symbol for the functions you desire Note Some of the unit s functions can only be controlled by the remote controller ELECTRONIC CONTROL OPERATING INSTRUCTIONS OPE...

Page 7: ...Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the unit is exposed to direct sunlight the air conditioner may not respond Close curtains blinds to bl...

Page 8: ...cessed Reset button is pressed all current settings will be cancelled and the controller will be reset to default 5 SLEEP Button Press to activate or disable Sleep function Select this function during...

Page 9: ...Off check the Timer indicator on the display panel is illuminated To Cancel press the CANCEL button will remove all timer settings To change setting repeat steps 1 to 3 OPERATING INSTRUCTIONS REMOTE...

Page 10: ...er a tap or spray with water hose May cause electrical danger If the power cord is damaged it should be repaired by manufacturer or certi ed electrician Air Filters Clean the lters at least once every...

Page 11: ...f purchase must be presented to Sunpentown s nominated representative The warranty will be void if the product if modi ed misused or repaired by an unauthorized person The warranty after repair will n...

Reviews: