INSTALLATION INSTRUCTIONS

Location

Window Slider kit Installation

     Note: If the window opening is less than the minimum
     required length and the slider kit needs to be cut down
     to size, cut the piece with the hole in it, but cut the end
     without the hole. Do not cut out the hole in the kit.

Fig.3

12 in

12 in

bolt

Window 
slider kit

Horizontal 
window

Horizontal 
window

Fig.5a

Fig.4

Fig.5

The air conditioner should be placed on a rm 
foundation to minimize noise and vibration. For 
safe and secure positioning, place the unit on a 
smooth, level oor strong enough to support the unit.
The unit has casters to aid placement, but it should
only be rolled on smooth, at surfaces. Use caution 
when rolling on carpet surfaces. Do not attempt to 
roll the unit over objects.
The unit must be placed within reach of a properly 
rated grounded socket.
Never place any obstacles around the air inlet or 
outlet of the unit.
Allow at least 12 inches of space from the wall for 
efcient air-conditioning. Fig.3.

     Your window slider kit has been designed to t most 
     standard vertical and horizontal window applications.
     However, it may be necessary for you to improvise or
     modify some aspects of the installation procedures for
     certain types of window. Please refer to Fig 4 & 5 for
     minimum and maximum window opening requirements.
     Window slider kit can be xed  with a bolt (Fig. 5a)

Window Slider Kit 
Minimum:26.5in (2.22ft).
Maxmum:48 in  (4.04ft).

Window Slider Kit 
Minimum:26.5 in (2.22ft).
Maxmum:48 in (4.04ft).

6

7

INSTALLATION  INSTRUCTIONS

INSTALLATION  INSTRUCTIONS

Installation for a double-hung sash window

Foam seal A
(adhesive type)

Foam seal

Fig.6

Fig.7

Fig.8

Fig.9

Window kit

Window stool

Window kit

Window stool

26.5 ~ 48.0

1. Trim foam seal (with adhesive) to the proper length and
    attach to window stool. Fig.6.

2.  Adjust the length of the slider kit according to the width
    of the window. Place slider kit to window stool, on top of
    foam seal. Fig.7.

3. Trim another foam seal (with adhesive) to the proper
    length and place on top of the slider kit.

4. Close the window sash securely against the kit. Fig.8.

5. Trim the last foam seal to the proper length to seal the 
    open gap between the top window sash and outer 
    window sash. Fig.9.

Installation for a sliding sash window

1. Trim foam seal (with adhesive) to the proper length and
    attach to window frame. Fig.10

2.  Adjust the length of the slider kit according to the height
    of the window. Place slider kit against foam seal. Fig.11.

3. Trim another foam seal (with adhesive) to the proper
    length and attached it to the open side of the slider kit.

4. Slide window close against the kit. Fig.12

5. Trim the last foam seal to the proper length to seal the 
    open gap between the two window sashes. Fig.13.

Foam seal

Foam seal A
(adhesive type)

Fig.10

Fig.11

Fig.12

Fig.13

Window
panel

26.5 ~ 48.0

Summary of Contents for WA-8088E

Page 1: ...properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions care...

Page 2: ...by authorized personnel only Installation work must be performed in accordance with the national wiring standards by authorized personnel only CAUTION Read This Manual CONTENTS The rating data indica...

Page 3: ...t use this product for functions other than those described in this instruction manual Never do this Safety rules Dispose packaging materials such as plastic and carton in the appropriate waste bins W...

Page 4: ...the room cool and keep the heat out Adaptor A connects unit to hose Adaptor B connects hose to slider kit Exhaust Hose Window Slider Kit and Bolt Wall adaptor for through the wall installation not in...

Page 5: ...irements Window slider kit can be xed with a bolt Fig 5a Window Slider Kit Minimum 26 5in 2 22ft Maxmum 48 in 4 04ft Window Slider Kit Minimum 26 5 in 2 22ft Maxmum 48 in 4 04ft 6 7 INSTALLATION INSTR...

Page 6: ...nd all its functions then follow the symbol for the functions you desire Note Some of the unit s functions can only be controlled by the remote controller ELECTRONIC CONTROL OPERATING INSTRUCTIONS OPE...

Page 7: ...Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the unit is exposed to direct sunlight the air conditioner may not respond Close curtains blinds to bl...

Page 8: ...cessed Reset button is pressed all current settings will be cancelled and the controller will be reset to default 5 SLEEP Button Press to activate or disable Sleep function Select this function during...

Page 9: ...Off check the Timer indicator on the display panel is illuminated To Cancel press the CANCEL button will remove all timer settings To change setting repeat steps 1 to 3 OPERATING INSTRUCTIONS REMOTE...

Page 10: ...er a tap or spray with water hose May cause electrical danger If the power cord is damaged it should be repaired by manufacturer or certi ed electrician Air Filters Clean the lters at least once every...

Page 11: ...f purchase must be presented to Sunpentown s nominated representative The warranty will be void if the product if modi ed misused or repaired by an unauthorized person The warranty after repair will n...