23
Fuse interrupted
Check conductance of
fuse
Replace fuse, or wait for
automatic circuit breaker
to cool down
Built-in
Current collector (slip
ring unit) has
no contact
Check carbon brushes and
springs in the housing
Replace carbon brushes,
make springs usable
Battery is not fully charged:
Possible cause
Test
Fix
Battery old, defective
Battery
voltage
and
capacity
with
Battery
tester (Hardware store
available) check.
Replace
battery,
refill
distilled water (not with gel
or AGM battery)
Fuse defective
Check conductance
Replace the defective fuse
and find the reason for the
defect
Charge controller
incorrectly connected
check according to plan
connect properly
Charge controller, stop
switch is set to "STOP"
Set the stop switch to
"ON"
Follow instructions in
manual
Generator defective,
cable short circuit
Check AC voltage at the
input of the charge
controller
After disconnecting the
charge controller, check
all three cables for short-
circuit interruptions
Charge controller
defective,
battery reverse polarity
Check settings according
to manual
Repair,
Customer service,
replacement