12
6. Cable sizing
System voltage 12 Volt:
Distance from wind
generator to charge
controller in m
0 - 9
10 – 19 20 – 29 30 – 44 45 – 69 70 – 110
Cable cross section in mm2
AWG
6
10
10
8
16
6
25
4
35
2
50
1
Distance from charge
Controller to Battery in m
0 - 9 10 – 19 20 – 29 30 – 44 45 – 69 70 – 110
Cable cross section in mm2
AWG
10
8
16
6
25
4
35
2
---
---
---
---
System voltage 24 Volt:
Distance from wind
generator to charge
controller in m
0 -
10
11 – 19 20 – 29 30 – 44 45 – 69 70 – 110
Cable cross section in mm2
AWG
2.5
14
4
12
6
10
10
8
16
6
25
4
Distance from charge
controller to Battery in m
0 - 9 10 – 19 20 – 29 30 – 44 45 – 69 70 – 110
Cable cross section in mm2
AWG
10
8
16
6
25
4
35
2
---
---
---
---