Data di emissione:
Novembre, 2015
Revisione:
1
Pag. :
17/24
SANITIZING
Whenever the machine has remained unused for
some days after been cleaned and sanitized as
described in the chapter 10, the sanitizing
procedures described below must be performed
just prior to start-up the machine.
- Remove the main cover and the secondary
one.
- Pour sanitizing solution (AMUCHINA®) into the
bowl carefully following the manufacturer
prescriptions.
- After restoring the main cover, switch on the
machine and let the auger rotating (all control
board LED switched off) leaving the sanitizing
solution for the time specified by its producer.
IMPORTANT
Never let the sanitizer inside the bowl for
more than 15 minutes.
- Drain the solution by opening the plunger to
allow the bowl to empty. Open and close the
plunger at least 10 times during draining to
sanitize the product way out area also.
- Thoroughly rinse repeating these operations
with clean water instead of sanitizer solution.
- Now the machine is ready to be used.
10. SPECIAL MAINTENTANCE
Caution
Before proceeding with any maintenance
operation, it is compulsory to switch off the
machine and unplug it from the mains.
Control and replacement of seals
BOWL GASKET (LOCATED AT THE REAR OF
BOWL)
Replace it every 12 months according to the
conditions of use and level of maintenance.
DISPENSE VALVE O-RING
The dispense valve O-rings should be replaced
as necessary when wear is evident. Lubricate
them each time they are replaced or the
dispense valve is removed for cleaning.
SUCTION GASKET
Replace every 3 months according to the
conditions of use and level of maintenance. This
part should be lubricated during the re-
assembly after every cleaning with Vaseline
Winter storage
To protect the unit during seasonal shutdown,
it’s important to properly store the machine
using the following procedures:
- Disconnect all power to the freezer.
- Disassemble, wash and sanitize all parts that
come into contact with the mix as described in
chapter 10.
- Clean also all the exterior panels.
- Reassemble all these parts.
- Cover the machine with the original package
to protect it from dust or other contaminating
elements.
- Place the machine in dry location.
Summary of Contents for NINA HOT Series
Page 1: ...Data di emissione Novembre 2015 Revisione 1 Pag 1 24 NINA HOT Operator s manual Page 2 ...
Page 20: ...Data di emissione Novembre 2015 Revisione 1 Pag 20 24 13 WIRING DIAGRAM ...
Page 21: ...Data di emissione Novembre 2015 Revisione 1 Pag 21 24 ...
Page 22: ...Data di emissione Novembre 2015 Revisione 1 Pag 22 24 ...