background image

FILTER PUMP INSTALLATION and INSTRUCTIONS

11

www.SereneLife.com

IMPORTANT SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always be followed, 
including the following:

1. 

READ AND FOLLOW ALL INSTRUCTIONS

2. 

WARNING –

 To reduce the risk of injury, do not permit children to use this product unless they are closely       

    supervised at all times;

3. 

WARNING –

 Risk of Electric Shock. Connect only to a grounding type receptacle. This product is provided  

    with a ground-fault circuit-interrupter. If replacement of the plug or cord is needed, use only identical  
    replacement parts;

4. For US market only, the unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push  
    the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the  
    GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without  
    the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock.
    Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service 
    representative before using;

5. The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter  
    (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the  
    GFCI, push the test button. The GFCI should interrupt power. Push the reset button. 
    Power should be restored. If the GFCI fails tooperate in this manner, the GFCI is defective. If the GFCI   
    interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating  
    the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem  
    corrected by a qualified service representative before using;

6. Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment;

7. 

WARNING –

 To reduce the risk of electric shock, replace damaged cord immediately;

8. 

WARNING –

 To reduce the risk of electric shock, do not use extension cord to connect unit to electric supply;  

    provide a properly located outlet;

9. 

CAUTION –

 This pump is for use with storable pools only. Do not use with permanently-installed pools. 

    A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled  
    to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such  
    that it cannot be readily disassembled for storage;

10. 

SAVE THESE INSTRUCTIONS.

Summary of Contents for SLPLRND12

Page 1: ...5 SLPORND18 Above Ground Swimming Pool Fast Setup and Durable Garden Backyard Lawn and Courtyard IMPORTANT SAFETY RULES Please read understand and follow all instructions carefully before installing a...

Page 2: ...CHEMICALS GENERAL AQUATIC SAFETY TROUBLESHOOTING GUIDE LIMITED WARRANTY SPECIAL INTRODUCTORY NOTE Please read this manual before setting up your pool This information will help extend the pool life a...

Page 3: ...t be visible at all times from the outside barrier of the pool If swimming at night use properly installed artificial lighting to illuminate all safety signs ladders pool floor and walkways Stay away...

Page 4: ...accessible surfaces to avoid injuries Non swimmers safety Continuous active and vigilant supervision of weak swimmers and non swimmers by a competent adult is required at all times remembering that c...

Page 5: ...pool water treated and practicing good hygiene Consult the water treatment guidelines in the user s manual Store chemicals e g water treatment cleaning or disinfection products out of the reach of chi...

Page 6: ...embling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale The number...

Page 7: ...high wind conditions Select an outdoor location for the pool with the following requirements in mind 1 The area where the pool is to be set up must be absolutely flat and level Do not set up the pool...

Page 8: ...reach of the pump s electrical connection 2 Horizontal Beams Assembly The frame pool s legs 7 and beams 5 fall into two groups The larger diameters are the horizontal beams that are slid pushed into...

Page 9: ...t 3 see drawing 3 1 Continue the process with all the vertical legs NOTE This pool size does not come with an all around center belt Lift the beams assembly and make sure all the legs are a vertical p...

Page 10: ...1 Make sure filter pump is not operating Disconnect line cord 2 To prevent water from escaping the pool unscrew the pool inlet nozzle 10 and strainer grid 11 from the strainer connectors and insert th...

Page 11: ...t be connected only to a supply circuit that is protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the...

Page 12: ...he filter pump 6 Screw on filter chamber cover onto top of the body of filter pump by hand 7 Connect the hoses same as the Installation illustration fixture the pump to the wall of pool Remember to us...

Page 13: ...p continuously for an extended period of time FILTER PUMP CLEANING AND REPLACEMENT 1 The filter cartridge in your pump filter system should be replaced approximately once per month 2 Periodically clea...

Page 14: ...4 www SereneLife com LADDER ASSEMBLY SPARE PARTS ITEM NO PIC DESCRIPTION QTY 1 2 3 4 5A 5B Screw Stair Step Connector for the upper handrails U shaped upper handrail Side bar A Side bar B 8 8 2 2 2 2...

Page 15: ...15 www SereneLife com 2 3 4...

Page 16: ...t in a bucket of water then add it to the pool water Likewise with liquid chlorine mix it immediately and thoroughly with the pool water 2 Never mix chemicals together Add the chemicals to the pool wa...

Page 17: ...ly 7 When the water stops draining start lifting the pool from the side opposite the drain leading any remaining water to the drain and emptying the pool completely 8 Disconnect hose and adapter when...

Page 18: ...r Round Frame Pool make sure that the top ring is properly inflated 2 Remove the skimmer if applicable or any accessories attached to the threaded strainer connector Replace strainer grid if necessary...

Page 19: ...is tripped Motor too hot and overload protection is shut o Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter or RCD Reset circuit breaker...

Page 20: ...ill be invalid Pool Liner and Frame Warranty 1 Year PROBLEM CAUSE SOLUTION PUMP DOESNT WORK Low water level Strainer screen plugged up An air leak on the intake hose Faulty motor or the impeller is ja...

Page 21: ...is limited warranty does not apply in the following circumstances If the Pool is subject to negligence abnormal use or application accident improper operation improper maintenance or storage If the Po...

Page 22: ...SLPLRND9 Recommended Age 6 Capacity 1 4 persons Water Capacity 3530L Filter Pump Power Supply 110V 120V 0 25A Pump Flow Rate 300Gal hr Ladder Dimensions 30 inches Product Dimensions 274 32 x 30 inches...

Page 23: ...23 www SereneLife com...

Page 24: ...Questions Comments We are here to help Phone 1 718 535 1800 Email support pyleusa com Serene...

Reviews: