L-L 283.01-SW 

  In addition to these operating and safety instructions, all accident prevention 

regulations as well as any standards relating to the installation and operation of 

heaters applicable in your country must be strictly followed. 

  This unit is not intended for use by children. Children must always be supervised 

when in the vicinity and ensure that they DO NOT play with the unit. Further, it is not 

intended for use by persons with reduced physical, sensory or mental capabilities, or 

lack of experience or knowledge.  

  The heater is not to be installed in an area where there is a risk of fire or explosions; 

  Never operate this heater in basements or below ground level because of gas 

stagnation. 

  Do not use the heater on floors made with flammable materials. 

  Do not store flammable materials in the vicinity of the heater (minimum distance: 3m); 

  Ensure no overheating of walls, or ceilings made of flammable materials, 

  Ensure all precautions have been taken to prevent fires; 

  Ensure the premises in which the heater is installed are sufficiently ventilated for the 

burner requirements; in particular, limits regarding air quality in the room to be heated 

must conform to applicable laws; 

  Ensure nothing is obstructing the aspiration and expulsion of air; movement of air may 

be obstructed in various ways including placing covers or other objects on the heater 

or positioning the heater too near a wall or other large object;   

  Never direct the hot air flow from the heater towards the gas cylinder   

  Ensure the heater is regularly monitored during operation and checked before being 

started;   

  Ensure at the beginning of each use, a check is made that the fan moves freely before 

plugging the heater into the electrical power supply;   

  Ensure at the end of each use, the mains switch is disengaged and supply power cord 

removed, main gas stopcock is closed and gas tube disengaged and sealed. 

 

1.  GENERAL ADVICE 

The heater must be installed, set up and used in accordance with the applicable 

regulations and laws relating to the use of such equipment.  Minimum distance from 

surrounding walls and/or ceiling: 2m. 

 

 

2.  ELECTRICAL CONNECTION 

  The voltage, hertz rating and number of phases on the data plate 

must correspond to that of the electrical mains outlet that the unit is 

being connected to.  

  Only connect the unit to electrical installations made by 

certified 

electricians and in keeping with local electrical regulations and 

requirements.

 

  It is recommended that the electrical supply to this unit should include either a 

residual current device that will interrupt the supply if the leakage current to earth 

exceeds 30mA for 30 ms

 or a device that will prove the earth circuit. 

  This Class 1 Appliance must only be connected to an earthed power supply fitted with 

an appropriately sized fuse. 

  The heater may be connected to a room thermostat by connecting to the thermostat plug 

(10).  Other accessories such as a timer may also be connected. 

 

 

3.  POWER CORD 

  Make sure before every use that the power cord assembly 

is not damaged or cut. If it is DO NOT connect the unit, 

Summary of Contents for JETFIRE J20A

Page 1: ...OR INDUSTRIAL USE ONLY Read and understand this instruction manual before operating this unit and retain for future reference and pass on with the unit in the event of a change of ownership Failure to...

Page 2: ...ange of heaters should only be used in the manner and purpose for which they were intended and in accordance with the recommendations and safety precautions detailed in this manual and in operating in...

Page 3: ...VOLUME 350 850 M3 FUEL FUEL TYPE Universal LPG Universal LPG GAS CYLINDER SIZE 45 45 Kg NOZZLE INJECTOR SIZE 1 1 1 2 mm ELECTRICAL ELECTRICAL SUPPLY 230 1 50 230 1 50 V Hz CONNECTED LOAD 90 240 W IGN...

Page 4: ...are used on the machine in order to warn user of potential injury if not cautious Their meaning is listed next to them for your attention WARNING Hot surface Do not touch will result in injury WARNIN...

Page 5: ...LS IN THE VICINITY OF THIS APPLIANCE WHILST IN OPERATION DO NOT USE OR STORE FLAMMABLE MATERIALS IN OR NEAR THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIAN...

Page 6: ...Never direct the hot air flow from the heater towards the gas cylinder Ensure the heater is regularly monitored during operation and checked before being started Ensure at the beginning of each use a...

Page 7: ...E CAUTION Use only in areas free from flammable materials flammable vapors high dust concentrations etc Keep combustible materials a safe distance from this unit minimum 3m An external guard should be...

Page 8: ...er spare parts when parts replacements are required Inspect the unit each day before use Follow Daily inspection check list guide Table B in the Maintenance section Service the unit regularly based on...

Page 9: ...Cylinders must be installed and stored in accordance with current local requirements Propane Gas Cylinders should always be installed connected and replaced in a flame free atmosphere Use Propane vapo...

Page 10: ...onnection START ALL MODELS To start the heater Set the pressure regulator to maximum pressure Slowly open the gas stopcock on the gas cylinder Warning In the case of a suspected gas leak close the gas...

Page 11: ...starting cycle slow flashing unit is in stand by status waiting for heating request steady light lock out status TRANSPORTING AND HANDLING The space heater can be lifted and moved easily by means of...

Page 12: ...on chamber Authorized service Agent Table A Time interval for checks and replacement listed above are for units subjected to normal operating conditions Should the unit be subjected to abnormal condit...

Page 13: ...structed 3 CHECKING THE ELECTRICAL CONNECTIONS After detaching the power cable check all electrical connections as follows Make sure that all connections are complete and tight If there are traces of...

Page 14: ...e damage to property and or people SERVICE CARE RECOMMENDATIONS AND TROUBLESHOOTING GUIDE To maintain this unit in peak working condition during its operating life it is necessary to carry out regular...

Page 15: ...nsure all guards covers and shields are in place before operating the unit Check the power cable for any cuts abrasions or damage Check fuel fittings and lines for leaks Check the unit is not damaged...

Page 16: ...t Spitwater service agent The flame does not light up Check that the suction and the flow grills are unobstructed Contact Spitwater service agent Faulty safety thermostat Check room thermostat and rep...

Page 17: ...ay require service Electrical System Protection The heater s electrical system is protected by a fuse mounted to the PCB assembly that protects the system components from damage If the heater fails ch...

Page 18: ...ng Diagram C Capacitor MV Fan motor FUA Fuse RV Switch PR Reset switch LI Overheat safety thermostat AP Control box TA Room thermostat plug EV Gas solenoid valve RP Resistence PA Air pressure switch E...

Reviews: