DESCRIPTION OF SYMBOLS 

 

The following symbols are used throughout this instruction booklet in order to mark important 

paragraphs or sections that are due particular attention. Their meaning is listed next to them for 

your attention. 

 

 

 

 

 

 

 

 

 

 

WARNING 

Failure to follow 

instruction could 

result in injury 

or death 

 

WARNING 

Failure to follow 

instruction could 

result in damage to 

machine 

 

These are tips 

and instructions 

to ensure safe 

and proper 

operation 

 

The following symbols are used on the machine in order to warn user of potential injury if not 

cautious.  Their meaning is listed next to them for your attention. 

 

 

WARNING 

Hot surface 

Do not touch, 

will result in 

injury 

 

WARNING 

Electric shock 

Disconnect power 

before removing 

cover 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS 

WARNING:  

This heater shall only be used by persons instructed in its use and who have 

been authorized to do so. Before using this heater please pay attention to the 

following safety warnings as failure to do so could result in serious injury or 

even death. 

 

 

SAFETY LABELS 

 

 

Always pay attention to the safety instructions provided on each label. Do not alter or 

remove safety labels 

 

 

Summary of Contents for JETFIRE J20A

Page 1: ...OR INDUSTRIAL USE ONLY Read and understand this instruction manual before operating this unit and retain for future reference and pass on with the unit in the event of a change of ownership Failure to...

Page 2: ...ange of heaters should only be used in the manner and purpose for which they were intended and in accordance with the recommendations and safety precautions detailed in this manual and in operating in...

Page 3: ...VOLUME 350 850 M3 FUEL FUEL TYPE Universal LPG Universal LPG GAS CYLINDER SIZE 45 45 Kg NOZZLE INJECTOR SIZE 1 1 1 2 mm ELECTRICAL ELECTRICAL SUPPLY 230 1 50 230 1 50 V Hz CONNECTED LOAD 90 240 W IGN...

Page 4: ...are used on the machine in order to warn user of potential injury if not cautious Their meaning is listed next to them for your attention WARNING Hot surface Do not touch will result in injury WARNIN...

Page 5: ...LS IN THE VICINITY OF THIS APPLIANCE WHILST IN OPERATION DO NOT USE OR STORE FLAMMABLE MATERIALS IN OR NEAR THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIAN...

Page 6: ...Never direct the hot air flow from the heater towards the gas cylinder Ensure the heater is regularly monitored during operation and checked before being started Ensure at the beginning of each use a...

Page 7: ...E CAUTION Use only in areas free from flammable materials flammable vapors high dust concentrations etc Keep combustible materials a safe distance from this unit minimum 3m An external guard should be...

Page 8: ...er spare parts when parts replacements are required Inspect the unit each day before use Follow Daily inspection check list guide Table B in the Maintenance section Service the unit regularly based on...

Page 9: ...Cylinders must be installed and stored in accordance with current local requirements Propane Gas Cylinders should always be installed connected and replaced in a flame free atmosphere Use Propane vapo...

Page 10: ...onnection START ALL MODELS To start the heater Set the pressure regulator to maximum pressure Slowly open the gas stopcock on the gas cylinder Warning In the case of a suspected gas leak close the gas...

Page 11: ...starting cycle slow flashing unit is in stand by status waiting for heating request steady light lock out status TRANSPORTING AND HANDLING The space heater can be lifted and moved easily by means of...

Page 12: ...on chamber Authorized service Agent Table A Time interval for checks and replacement listed above are for units subjected to normal operating conditions Should the unit be subjected to abnormal condit...

Page 13: ...structed 3 CHECKING THE ELECTRICAL CONNECTIONS After detaching the power cable check all electrical connections as follows Make sure that all connections are complete and tight If there are traces of...

Page 14: ...e damage to property and or people SERVICE CARE RECOMMENDATIONS AND TROUBLESHOOTING GUIDE To maintain this unit in peak working condition during its operating life it is necessary to carry out regular...

Page 15: ...nsure all guards covers and shields are in place before operating the unit Check the power cable for any cuts abrasions or damage Check fuel fittings and lines for leaks Check the unit is not damaged...

Page 16: ...t Spitwater service agent The flame does not light up Check that the suction and the flow grills are unobstructed Contact Spitwater service agent Faulty safety thermostat Check room thermostat and rep...

Page 17: ...ay require service Electrical System Protection The heater s electrical system is protected by a fuse mounted to the PCB assembly that protects the system components from damage If the heater fails ch...

Page 18: ...ng Diagram C Capacitor MV Fan motor FUA Fuse RV Switch PR Reset switch LI Overheat safety thermostat AP Control box TA Room thermostat plug EV Gas solenoid valve RP Resistence PA Air pressure switch E...