background image

L-L 283.01-SW 

 

 

INTRODUCTION 

 

Spitwater Australia is proudly Australian owned and operated since 1983. Our promise is to 

provide our customers with superior quality portable industrial heaters built to the highest of 

standards that will see many years of reliable service. 

The JETFIRE range of portable industrial heaters are designed to give safe, efficient and 

reliable service when the correct operating and safety instructions are followed, and proper 

attention is given to all required maintenance procedures in order to maintain the unit in peak 

operating condition. 

This manual provides the up to date information necessary for the user to operate the unit and 

carry out regular inspection and maintenance. 

Please note that the information given within this manual may be subject to revision in 

compliance with Spitwater Australia’s policy of continual improvement. 

 

The JETFIRE range of heaters should only be used in the manner and purpose for which they 

were intended 

and in accordance with the recommendations and safety precautions detailed in this manual 

and in operating instructions and stickers on the unit itself.   

 

 

 

 

All JETFIRE heaters undergo rigorous safety and operational tests before being dispatched into 

the marketplace however it is still imperative that prior to used, all operators have read and 

understood all information and instructions provided and are aware of possible hazards. 

 

GENERAL DESCRIPTION & INTENDED USE 

 

Jetfire Heaters are specifically designed to solve all problems relating to heating drying and 

desiccating in commercial and industrial applications. Some examples of applications are in 

warehouse and factory heating, animal husbandry and greenhouse applications. 

 

 

SPARE PARTS, ACCESSORIES & SERVICE 

 

Spitwater has an extensive range of spare parts and accessories to suit all your heating needs.   

For spare parts, accessories and service please refer to the contact section on 

www.spitwater.com.au or contact 

1800 SPITWATER (1800 774 892)

 

 

Summary of Contents for JETFIRE J20A

Page 1: ...OR INDUSTRIAL USE ONLY Read and understand this instruction manual before operating this unit and retain for future reference and pass on with the unit in the event of a change of ownership Failure to...

Page 2: ...ange of heaters should only be used in the manner and purpose for which they were intended and in accordance with the recommendations and safety precautions detailed in this manual and in operating in...

Page 3: ...VOLUME 350 850 M3 FUEL FUEL TYPE Universal LPG Universal LPG GAS CYLINDER SIZE 45 45 Kg NOZZLE INJECTOR SIZE 1 1 1 2 mm ELECTRICAL ELECTRICAL SUPPLY 230 1 50 230 1 50 V Hz CONNECTED LOAD 90 240 W IGN...

Page 4: ...are used on the machine in order to warn user of potential injury if not cautious Their meaning is listed next to them for your attention WARNING Hot surface Do not touch will result in injury WARNIN...

Page 5: ...LS IN THE VICINITY OF THIS APPLIANCE WHILST IN OPERATION DO NOT USE OR STORE FLAMMABLE MATERIALS IN OR NEAR THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIAN...

Page 6: ...Never direct the hot air flow from the heater towards the gas cylinder Ensure the heater is regularly monitored during operation and checked before being started Ensure at the beginning of each use a...

Page 7: ...E CAUTION Use only in areas free from flammable materials flammable vapors high dust concentrations etc Keep combustible materials a safe distance from this unit minimum 3m An external guard should be...

Page 8: ...er spare parts when parts replacements are required Inspect the unit each day before use Follow Daily inspection check list guide Table B in the Maintenance section Service the unit regularly based on...

Page 9: ...Cylinders must be installed and stored in accordance with current local requirements Propane Gas Cylinders should always be installed connected and replaced in a flame free atmosphere Use Propane vapo...

Page 10: ...onnection START ALL MODELS To start the heater Set the pressure regulator to maximum pressure Slowly open the gas stopcock on the gas cylinder Warning In the case of a suspected gas leak close the gas...

Page 11: ...starting cycle slow flashing unit is in stand by status waiting for heating request steady light lock out status TRANSPORTING AND HANDLING The space heater can be lifted and moved easily by means of...

Page 12: ...on chamber Authorized service Agent Table A Time interval for checks and replacement listed above are for units subjected to normal operating conditions Should the unit be subjected to abnormal condit...

Page 13: ...structed 3 CHECKING THE ELECTRICAL CONNECTIONS After detaching the power cable check all electrical connections as follows Make sure that all connections are complete and tight If there are traces of...

Page 14: ...e damage to property and or people SERVICE CARE RECOMMENDATIONS AND TROUBLESHOOTING GUIDE To maintain this unit in peak working condition during its operating life it is necessary to carry out regular...

Page 15: ...nsure all guards covers and shields are in place before operating the unit Check the power cable for any cuts abrasions or damage Check fuel fittings and lines for leaks Check the unit is not damaged...

Page 16: ...t Spitwater service agent The flame does not light up Check that the suction and the flow grills are unobstructed Contact Spitwater service agent Faulty safety thermostat Check room thermostat and rep...

Page 17: ...ay require service Electrical System Protection The heater s electrical system is protected by a fuse mounted to the PCB assembly that protects the system components from damage If the heater fails ch...

Page 18: ...ng Diagram C Capacitor MV Fan motor FUA Fuse RV Switch PR Reset switch LI Overheat safety thermostat AP Control box TA Room thermostat plug EV Gas solenoid valve RP Resistence PA Air pressure switch E...

Reviews: