![Spirax Sarco DLV7 Installation And Maintenance Instructions Manual Download Page 30](http://html1.mh-extra.com/html/spirax-sarco/dlv7/dlv7_installation-and-maintenance-instructions-manual_1347915030.webp)
IM-P204-03
CH Issue 8
30
5.3 Replacement of the bellows assembly
Gasket surfaces
4
Remove the bellows guide plate and
clean the gasket surfaces.
2
Remove the head set.
Hold the lock-nut
B
using a 22 mm A / F
spanner and loosen the head adaptor
nut
C
with a 24 mm A / F spanner.
Caution:
to prevent any damage care
must be taken not to twist the bellows.
C
A
B
Screw two M14 nuts on to the valve stem
and tighten together.
Note:
only tighten nut
B
to ensure no
damage to the bellows.
1
B
3
Summary of Contents for DLV7
Page 40: ...IM P204 03 CH Issue 8 40...