- 14 -
IMPORTANT
When fitting a plug to the mains lead it is essential that it contains an
earthing/grounding contact and that this is connected. Under no circumstances
should this equipment be connected to a mains supply which does not include an
earthing/grounding wire and contacts. e.g.. 2 –Wire extension leads as used for
some domestic equipment
MUST NOT BE USED.
NOTE:-
The cable colour coding used for the Control Unit and its supplied mains cable is as
follows:-
Pole
US/JAPAN
U.K.
Live
L
Black
Brown
Neutral
N
White
Blue
Earth / Ground
E
Green
Green/Yellow
For U.K. Equipment:
The wire which is coloured
GREEN and YELLOW
must be connected to the terminal in the
plug which is marked with the letter
E
or by the earth symbol, or coloured green or green and
yellow. The wire which is coloured
BLUE
must be connected to the terminal which is marked
with the letter
N
or coloured black. The wire which is coloured
BROWN
must be connected to
the terminal which is marked with the letter
L
or coloured red.
NOTE:-
The terminals used in the mains connector on the control panel of the unit are:-
POLE
PIN No.
Live
Pin 1
Neutral
Pin 3
Earth / Ground
Pin E
The method of disconnection from the mains electrical supply is by removal of the mains lead
plug from its respective supply socket.
OPERATING PRINCIPLE
The SAS control power supply transforms the 110/220 Vac into an adjustable voltage
which can be set from 3.5 to 13 Vdc.
The generator at the spray head converts the 12 Vdc into 85 kV negative charge, the
material being applied is drawn to the positively grounded product.