background image

2

Panther HIP-PAC

WARNING─Continued

this  testing  should  be  well  docu-

mented.  Seek  the  help  of  a  certified 

safety  professional  or  industrial  hy

-

gienist.  DO  NOT  USE  this  equipment 

if  the  user  would  be  endangered  in 

any way through environmentally in

-

duced degradation of the materials in 

the apparatus.

• All persons using this SPERIAN respi

-

rator must be made aware of its limita

-

tions. We cannot be responsible for any 

damage to property, personal injury, or 

death in which environmental exposure 

is a contributing factor.

• SPERIAN cannot predict what will hap

-

pen to this equipment in every potential 

environment.  Materials  can  be  chemi

-

cally attacked if exposed to the wrong 

environment and may exhibit corrosion 

or other forms of damage. Permeation 

or penetration of gases, liquids, or par

-

ticles  through  the  materials  could  be 

excessive.  Extremes  of  temperature 

might cause thermal degradation. Each 

of  these  things,  or  a  combination  of 

them, could create conditions in which 

this SPERIAN equipment would be dan

-

gerous to use.

• This respirator must be used in con

-

junction  with  a  written  respirator  pro-

gram  meeting  the  requirements  of  the 

OSHA Standard for Respiratory Protec

-

tion 29 CFR 1910.134, available from the 

U.S. Department of Labor, Occupational 

Safety  and  Health  Administration.  The 

program  must  include,  but  not  be  lim-

ited  to,  procedures  for  evaluating  air 

contaminants and selecting appropriate 

respirators, procedures for proper use 

of  respirators,  procedures  for  testing 

the  facepiece-to-face  fit  of  respirators, 

procedures  for  cleaning,  disinfecting, 

inspecting,  maintaining,  and  storing 

respirators, procedures for determining 

if  workers  are  physically  and  medical

-

ly  capable  of  wearing  respirators,  and 

procedures  for  training  employees  in 

the use of respirators and in recogniz

-

ing  the  hazards  associated  with  con

-

taminants in the workplace.

•  The  air  supply  must  meet  the  guide

-

lines of the Compressed Gas Associa

-

tion (CGA) pamphlet G-7.1, Grade D Air, 

as appropriate.

• DO not wear this respirator if a satis

-

factory fit, as determined by a qualita

-

tive  or  quantitative  fit  test,  cannot  be 

obtained. See ANSI Z88.2, latest edition, 

and  OSHA  1910.134.  Beards  and  side

-

burns will prevent good facepiece seal. 

Do  not  use  this  respirator  unless  you 

are clean shaven.

WARNING─Continued

•  This  respirator  does  not  protect  ex

-

posed areas of the body. Some contam

-

inants can be absorbed directly through 

the  skin  while  others  may  irritate  ex

-

posed  areas.  This  respirator  does  not 

provide protection from splash of haz

-

ardous  liquids,  flying  objects,  hazard

-

ous rays, or harmful noise. Always wear 

proper head, ear, and eye protection.

• This respirator is designed for use in 

temperatures above -30°F.

• When using this respirator at tempera

-

tures of 0 to -30°F, the first stage regu

-

lator  must  be  wrench  tightened  on  the 

cylinder  valve,  and  anti-fog  solution, 

P/N 951015 or 951016, must be applied 

to the inside of the facepiece lens.

• The Panther HIP-PAC has a rated ser

-

vice time of 5, 10, or 15 minutes. Under 

average conditions, you will have up to 

5, 10, or 15 minutes in which to escape 

from  a  toxic  environment.  Stress  and 

exertion may cause extra air consump-

tion and reduce the service time. Know 

escape routes in advance and the time 

required to travel them.

•  Compressors,  storage  cylinders, 

valves,  regulators,  fittings,  and  other 

hardware  must  be  large  enough  to  de-

liver the air volume required by all us

-

ers at peak demand.

•  This  respirator  will  reduce,  but  will 

not  eliminate  the  inhalation  of  con

-

taminants.  Some  sensitive  individuals 

may  experience  health  problems  when 

exposed  to  even  minute  amounts  of 

contaminants.  This  respirator  will  not 

prevent health problems for those indi

-

viduals.

•  Do  not  modify  this  respirator  in  any 

manner.

•  This  respirator  must  only  be  worn 

and used as specified in SPERIAN’s in

-

structions. Always read and follow the 

instructions listed in the Material Safe

-

ty Data Sheet for the chemicals that are 

present in the work area. Selection and 

use of these respirators must be done 

in  accordance  with  ANSI  Z88.2,  latest 
edition, and the applicable OSHA stat-
utes.

• Do not use SPERIAN respirators, ac

-

cessories, and associated equipment in 
atmospheres  which  may  contain  con-

taminant concentrations above the low

-

er explosive limit (LEL). Intrinsic safety 

certification  of  electronic  components 

does  not  eliminate  potential  danger 

from ignition in these atmospheres.

Summary of Contents for Panther Hip-Pac 9649

Page 1: ...D BREATHING APPARATUS P9684 SERIES 5 and 10 Minute Escape P9685 SERIES 15 Minute Escape P9686 SERIES HP 10 Minute Escape 9649 SERIES HP 10 Minute Escape OPERATION MANUAL WARNING DO NOT USE this respir...

Page 2: ......

Page 3: ...valve and pressure gauge assembly first stage regulator second stage regulator facepiece waist belt and regulator hose The cylinder stores 8 cubic feet of air at 2216 psig for the 5 minute apparatus...

Page 4: ...st cannot be obtained See ANSI Z88 2 latest edition and OSHA 1910 134 Beards and side burns will prevent good facepiece seal Do not use this respirator unless you are clean shaven WARNING Continued Th...

Page 5: ...ering the face piece and causing a severe reaction Do not use this respirator if you have been sensitized from previous exposure or believe that you may be sensitive or al lergic to any chemical until...

Page 6: ...tacles Kit all 2020 Series Facepieces Wire Frame 964044 Spectacles Kit all 2020 Series Facepieces NexSpex B140095 Lens Cover Clear Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 L...

Page 7: ...Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 Lens Cover Clear TwentyTwenty Plus 951015 Anti fog Solution 1 oz 951016 Anti fog Solution 16 oz 981805 Anti fog Wipes Box of 100 B14...

Page 8: ...rator hose This operation requires a torque wrench WARNING Carefully inspect and clean all threads to remove foreign material Foreign ma terial entering the air line can restrict or block air flow to...

Page 9: ...turned on while connect ed to the air supply will cause loss of air in the cylinder resulting in reduced es cape time in case of an emergency Always disengage the regulator from the facepiece and ret...

Page 10: ...operly on the face and the regulator installed and activated Failure to comply with this Warning may lead to serious personal injury se rious illness or death 16 There are two methods depending upon w...

Page 11: ...ens The Challenge NXT PVC lens neoprene neck seal and adhesive all may react in a different manner when exposed to chemicals or chemical mixtures You must verify that none of the components of the hoo...

Page 12: ...tons when installing the regulator WARNING Rotate and tug the regulator to ensure that both release buttons are properly engaged in the AIR KLIC Do not push the release buttons while verifying the eng...

Page 13: ...eathing exhale forcefully The regulator should return to normal flow b If the free flow continues open and close the by pass once or depress the manual override button once c If the problem persists I...

Page 14: ...water and a mild detergent 2 Fully immerse the facepiece in the solution 3 Agitate the facepiece and gently clean with a soft brush 4 Thoroughly rinse the facepiece in fresh water paying particular a...

Page 15: ...cleaning may require reapplication of anti fog coating to the facepiece lens Use only SPERIAN Anti Fog Solution P N 951015 1 oz or P N 951016 16 oz 6 After cleaning three drops of anti fog solution m...

Page 16: ...ly rinse the exterior surfaces and the interior of the outlet tube with fresh water Scrub excess soap away with the brush 5 Dry with a clean cloth or with low pressure 15 psig maximum clean breathing...

Page 17: ...F Cylinders damaged by fire or exposed to heat of 350 F must be destroyed Repainted or refinished cylinders must be hydrostatically tested before reuse WARNING Continued Do not fill a composite cylind...

Page 18: ...l be maintained at 65 F 53 9 C or lower or less than 24 0 ppm by volume moisture content UNDER NO CIRCUM STANCES SHALL AN AIR CYLINDER BE FILLED OR PARTIALLY FILLED WITH OXYGEN b Maximum Fill Pressure...

Page 19: ...cold weather problems however cold weather condi tions may also cause other problems not listed below 1 Air Supply NOTE Cold weather conditions require very dry air Moisture entering the HIP PAC may...

Page 20: ...e and regulator until the normal function of the AIR KLIC button and or the shutoff button returns j Should ice form on the regulator while the regula tor is in the regulator receiver rotate the regul...

Page 21: ...tures especially if there is ice d Use HIP PAC accessories with extreme care in cold weather conditions Visually inspect them pe riodically for ice J Storage Inspect clean and repair as required befor...

Page 22: ...placement or repair of defective parts and such other necessary maintenance and repair as may be required Normal wear and tear and parts damaged by abuse misuse negligence or accidents are specificall...

Page 23: ...k seal to tear SECOND STAGE REGULATOR AND HOSE 1 Cracks or heat damage to housing or cover 2 Faulty operation of bypass valve First Breath On AIR KLIC or override buttons 3 Dirt and debris in the outl...

Page 24: ...remove the rim nuts and screws 2 Gently separate the rims from the facepiece 3 Pull the silicone skirt away from the lens 4 Remove the old lens 5 Match one corner of the new lens with a corner of the...

Page 25: ...disconnect nipple 4 Listen to the second stage regulator it should not flow 5 Listen for leaks at all hose connections 6 Don the facepiece 7 Connect the facepiece to the second stage regulator and in...

Page 26: ...ation Specifica tion G 7 1 for Type 1 Grade D air having a moisture content expressed as dewpoint of 65 F or lower The cylinder shall be marked Fill With Compressed Air Only and shall meet applicable...

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ...www sperianprotection com...

Reviews: