background image

14

Panther HIP-PAC

Green All Purpose Cleaner.

6. Allow the hood to drip dry. Warm air may be used 
to speed up drying.

7. Hold the hood facepiece inner mask firmly 

against your face and exhale several times to en-
sure that the exhalation valve functions smoothly.

8. After cleaning and disinfecting the hood, liber-
ally apply SPERIAN anti-fog solution, P/N 951015, 
951016, or 981805 to the inside of the lens and 
allow it to dry thoroughly.

C. Second Stage Regulator Cleaning

WARNING

•  Do  not  allow  water  or  cleaning  solu

-

tions  to  enter  the  breathing  system  or 
the regulator. Dirt, dust, or soap residue 

could  degrade  regulator  performance 

causing  it  to  fail,  possibly  resulting  in 

injury or death.

• Do not submerge the regulator in wa

-

ter or cleaning solutions. It may be par-
tially  submerged  only  as  instructed  in 

step 6 below.

•  Failure  to  comply  with  this  Warning 

may lead to serious personal injury, se-
rious illness, or death.

NOTE

• Always hold the regulator with the outlet 

facing  downward  during  washing  and 
rinsing.

• The Protective Cleaning Cap, P/N 873004, 

may  be  used  to  seal  the  Panther  second 
stage  regulator  to  prevent  contaminants 
from  entering  the  regulator  outlet.  See 
Figure 12.

1. Make a cleaning solution of warm water and a mild 

detergent.

2. Have a bucket of fresh water available for rinsing.

Figure 12. Protective Cleaning Cap

3. With the regulator facing downward, clean the ex-
terior surfaces and the interior of the outlet tube with 
a soft brush.

4.  With  the  regulator  facing  downward,  immediately 
rinse the exterior surfaces and the interior of the outlet 
tube with fresh water. Scrub excess soap away with 
the brush.

5. Dry with a clean cloth or with low pressure (15 psig 
maximum) clean (breathing grade) air.

6. If dirt or debris interferes with the First-Breath-On 

mechanism, clean it as follows:

a. Lift the edge of the rubber manual override button 

with a small, flat-blade screwdriver, and peel it off.

b. Place the protective cap over the outlet tube.

c.  Hold  the  regulator  with  the  cover  facing  down-

ward and rinse in a shallow bucket of fresh water.

d. Allow the water to drain, and dry with low pres-
sure air (15 psig maximum).

e. Replace the manual override button.

D. Exterior Surfaces Cleaning

CAUTION

The  hoses,  backpack  harness,  frame, 

and  cylinder  and  valve  assembly  may 

be cleaned with a damp cloth or a mild 
soap  and  warm  water  solution.  Rinse 
thoroughly  and  air  dry  or  wipe  with  a 
clean cloth.

E. Inspection (see page 21)

F. Repair (see page 22)

WARNING

Before disassembly, make sure that all 

air  is  bled  from  the  lines.  Shut  off  or 

deplete the air supply to prevent equip

-

ment damage or personal injury. Failure 
to comply with this Warning may lead to 
serious personal injury, serious illness, 
or death.

CAUTION

User repair of the Panther HIP-PAC is 
limited to replacement of components 
listed on the NIOSH approval label and 
repairs described in this section. Disas-
sembly should be performed only to the 
extent necessary to replace the compo-
nents. To protect your warranty and the 

NIOSH certification on the equipment, 

all other repairs must be done only by 

SPERIAN-certified technicians. If there 

are none at your facility, consult your 
SPERIAN distributor for the repair facil-
ity nearest you.

.

Summary of Contents for Panther Hip-Pac 9649

Page 1: ...D BREATHING APPARATUS P9684 SERIES 5 and 10 Minute Escape P9685 SERIES 15 Minute Escape P9686 SERIES HP 10 Minute Escape 9649 SERIES HP 10 Minute Escape OPERATION MANUAL WARNING DO NOT USE this respir...

Page 2: ......

Page 3: ...valve and pressure gauge assembly first stage regulator second stage regulator facepiece waist belt and regulator hose The cylinder stores 8 cubic feet of air at 2216 psig for the 5 minute apparatus...

Page 4: ...st cannot be obtained See ANSI Z88 2 latest edition and OSHA 1910 134 Beards and side burns will prevent good facepiece seal Do not use this respirator unless you are clean shaven WARNING Continued Th...

Page 5: ...ering the face piece and causing a severe reaction Do not use this respirator if you have been sensitized from previous exposure or believe that you may be sensitive or al lergic to any chemical until...

Page 6: ...tacles Kit all 2020 Series Facepieces Wire Frame 964044 Spectacles Kit all 2020 Series Facepieces NexSpex B140095 Lens Cover Clear Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 L...

Page 7: ...Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 Lens Cover Clear TwentyTwenty Plus 951015 Anti fog Solution 1 oz 951016 Anti fog Solution 16 oz 981805 Anti fog Wipes Box of 100 B14...

Page 8: ...rator hose This operation requires a torque wrench WARNING Carefully inspect and clean all threads to remove foreign material Foreign ma terial entering the air line can restrict or block air flow to...

Page 9: ...turned on while connect ed to the air supply will cause loss of air in the cylinder resulting in reduced es cape time in case of an emergency Always disengage the regulator from the facepiece and ret...

Page 10: ...operly on the face and the regulator installed and activated Failure to comply with this Warning may lead to serious personal injury se rious illness or death 16 There are two methods depending upon w...

Page 11: ...ens The Challenge NXT PVC lens neoprene neck seal and adhesive all may react in a different manner when exposed to chemicals or chemical mixtures You must verify that none of the components of the hoo...

Page 12: ...tons when installing the regulator WARNING Rotate and tug the regulator to ensure that both release buttons are properly engaged in the AIR KLIC Do not push the release buttons while verifying the eng...

Page 13: ...eathing exhale forcefully The regulator should return to normal flow b If the free flow continues open and close the by pass once or depress the manual override button once c If the problem persists I...

Page 14: ...water and a mild detergent 2 Fully immerse the facepiece in the solution 3 Agitate the facepiece and gently clean with a soft brush 4 Thoroughly rinse the facepiece in fresh water paying particular a...

Page 15: ...cleaning may require reapplication of anti fog coating to the facepiece lens Use only SPERIAN Anti Fog Solution P N 951015 1 oz or P N 951016 16 oz 6 After cleaning three drops of anti fog solution m...

Page 16: ...ly rinse the exterior surfaces and the interior of the outlet tube with fresh water Scrub excess soap away with the brush 5 Dry with a clean cloth or with low pressure 15 psig maximum clean breathing...

Page 17: ...F Cylinders damaged by fire or exposed to heat of 350 F must be destroyed Repainted or refinished cylinders must be hydrostatically tested before reuse WARNING Continued Do not fill a composite cylind...

Page 18: ...l be maintained at 65 F 53 9 C or lower or less than 24 0 ppm by volume moisture content UNDER NO CIRCUM STANCES SHALL AN AIR CYLINDER BE FILLED OR PARTIALLY FILLED WITH OXYGEN b Maximum Fill Pressure...

Page 19: ...cold weather problems however cold weather condi tions may also cause other problems not listed below 1 Air Supply NOTE Cold weather conditions require very dry air Moisture entering the HIP PAC may...

Page 20: ...e and regulator until the normal function of the AIR KLIC button and or the shutoff button returns j Should ice form on the regulator while the regula tor is in the regulator receiver rotate the regul...

Page 21: ...tures especially if there is ice d Use HIP PAC accessories with extreme care in cold weather conditions Visually inspect them pe riodically for ice J Storage Inspect clean and repair as required befor...

Page 22: ...placement or repair of defective parts and such other necessary maintenance and repair as may be required Normal wear and tear and parts damaged by abuse misuse negligence or accidents are specificall...

Page 23: ...k seal to tear SECOND STAGE REGULATOR AND HOSE 1 Cracks or heat damage to housing or cover 2 Faulty operation of bypass valve First Breath On AIR KLIC or override buttons 3 Dirt and debris in the outl...

Page 24: ...remove the rim nuts and screws 2 Gently separate the rims from the facepiece 3 Pull the silicone skirt away from the lens 4 Remove the old lens 5 Match one corner of the new lens with a corner of the...

Page 25: ...disconnect nipple 4 Listen to the second stage regulator it should not flow 5 Listen for leaks at all hose connections 6 Don the facepiece 7 Connect the facepiece to the second stage regulator and in...

Page 26: ...ation Specifica tion G 7 1 for Type 1 Grade D air having a moisture content expressed as dewpoint of 65 F or lower The cylinder shall be marked Fill With Compressed Air Only and shall meet applicable...

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ...www sperianprotection com...

Reviews: