background image

3

Panther HIP-PAC

WARNING─Continued

•  Some  individuals  are  sensitive  to 

chemicals  (e.g.,  isocyanates  or  paint 
hardeners, latex, oil mists, etc.) or may 

have  some  type  of  respiratory  disor

-

der  (e.g.,  asthma,  chronic  obstructive 

airway  disease,  etc.).  If  you  are  sensi

-

tive to any chemical or have a respira

-

tory  disorder,  you  may  have  a  severe 

reaction  at  contaminant  levels  well 

below  accepted  health  levels,  such  as 

the  OSHA  Permissible  Exposure  Lim

-

it  (PEL),  AIHA  Threshold  Limit  Value 

(TLV), or the NIOSH Recommended Ex

-

posure  Limits  (REL).  Many  chemicals 

(e.g.,  isocyanates,  mercury,  etc.)  have 

no physical warning properties and you 
cannot taste or smell the contaminants 

even though they may be present in the 

respirator facepiece. This respirator will 

reduce, but will not eliminate the possi-

bility of contaminants entering the face

-

piece and causing a severe reaction. Do 

not use this respirator if you have been 

sensitized  from  previous  exposure  or 

believe that you may be sensitive or al

-

lergic  to  any  chemical  until  you  obtain 

clearance from a medical doctor.

•  Users  must  clean  and  maintain  this 

respirator  only  in  accordance  with 

SPERIAN’s  instructions.  Accessories 

not offered by SPERIAN may degrade 

performance, and will void NIOSH cer

-

tification.

•  The  respirator  facepiece  assembly 

contains  natural  rubber  latex  which 
may  cause  allergic  reactions  in  some 

individuals. Discontinue use if you ex

-

perience an allergic reaction.

• Discontinue use if you experience skin 

irritation or discoloration.

•  FAILURE  TO  OBSERVE  ALL  WARN

-

INGS  MAY  RESULT  IN  SERIOUS  PER

-

SONAL INJURY, SERIOUS ILLNESS, OR 

DEATH.

Figure 1A. Low Pressure HIP-PACs

2216 psig & 3000 psig

IV.  PARTS  LIST  (See  Figure  1A  for  low  pressure 
2216 psig & 3000 psig HIP-PACs and Figure 1B for 
high pressure 4500 psig HIP-PAC.)

Figure 1B. High Pressure HIP-PAC, 4500 psig

Summary of Contents for Panther Hip-Pac 9649

Page 1: ...D BREATHING APPARATUS P9684 SERIES 5 and 10 Minute Escape P9685 SERIES 15 Minute Escape P9686 SERIES HP 10 Minute Escape 9649 SERIES HP 10 Minute Escape OPERATION MANUAL WARNING DO NOT USE this respir...

Page 2: ......

Page 3: ...valve and pressure gauge assembly first stage regulator second stage regulator facepiece waist belt and regulator hose The cylinder stores 8 cubic feet of air at 2216 psig for the 5 minute apparatus...

Page 4: ...st cannot be obtained See ANSI Z88 2 latest edition and OSHA 1910 134 Beards and side burns will prevent good facepiece seal Do not use this respirator unless you are clean shaven WARNING Continued Th...

Page 5: ...ering the face piece and causing a severe reaction Do not use this respirator if you have been sensitized from previous exposure or believe that you may be sensitive or al lergic to any chemical until...

Page 6: ...tacles Kit all 2020 Series Facepieces Wire Frame 964044 Spectacles Kit all 2020 Series Facepieces NexSpex B140095 Lens Cover Clear Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 L...

Page 7: ...Classic Facepiece 702019 Lens Cover Tinted TwentyTwenty Plus 702028 Lens Cover Clear TwentyTwenty Plus 951015 Anti fog Solution 1 oz 951016 Anti fog Solution 16 oz 981805 Anti fog Wipes Box of 100 B14...

Page 8: ...rator hose This operation requires a torque wrench WARNING Carefully inspect and clean all threads to remove foreign material Foreign ma terial entering the air line can restrict or block air flow to...

Page 9: ...turned on while connect ed to the air supply will cause loss of air in the cylinder resulting in reduced es cape time in case of an emergency Always disengage the regulator from the facepiece and ret...

Page 10: ...operly on the face and the regulator installed and activated Failure to comply with this Warning may lead to serious personal injury se rious illness or death 16 There are two methods depending upon w...

Page 11: ...ens The Challenge NXT PVC lens neoprene neck seal and adhesive all may react in a different manner when exposed to chemicals or chemical mixtures You must verify that none of the components of the hoo...

Page 12: ...tons when installing the regulator WARNING Rotate and tug the regulator to ensure that both release buttons are properly engaged in the AIR KLIC Do not push the release buttons while verifying the eng...

Page 13: ...eathing exhale forcefully The regulator should return to normal flow b If the free flow continues open and close the by pass once or depress the manual override button once c If the problem persists I...

Page 14: ...water and a mild detergent 2 Fully immerse the facepiece in the solution 3 Agitate the facepiece and gently clean with a soft brush 4 Thoroughly rinse the facepiece in fresh water paying particular a...

Page 15: ...cleaning may require reapplication of anti fog coating to the facepiece lens Use only SPERIAN Anti Fog Solution P N 951015 1 oz or P N 951016 16 oz 6 After cleaning three drops of anti fog solution m...

Page 16: ...ly rinse the exterior surfaces and the interior of the outlet tube with fresh water Scrub excess soap away with the brush 5 Dry with a clean cloth or with low pressure 15 psig maximum clean breathing...

Page 17: ...F Cylinders damaged by fire or exposed to heat of 350 F must be destroyed Repainted or refinished cylinders must be hydrostatically tested before reuse WARNING Continued Do not fill a composite cylind...

Page 18: ...l be maintained at 65 F 53 9 C or lower or less than 24 0 ppm by volume moisture content UNDER NO CIRCUM STANCES SHALL AN AIR CYLINDER BE FILLED OR PARTIALLY FILLED WITH OXYGEN b Maximum Fill Pressure...

Page 19: ...cold weather problems however cold weather condi tions may also cause other problems not listed below 1 Air Supply NOTE Cold weather conditions require very dry air Moisture entering the HIP PAC may...

Page 20: ...e and regulator until the normal function of the AIR KLIC button and or the shutoff button returns j Should ice form on the regulator while the regula tor is in the regulator receiver rotate the regul...

Page 21: ...tures especially if there is ice d Use HIP PAC accessories with extreme care in cold weather conditions Visually inspect them pe riodically for ice J Storage Inspect clean and repair as required befor...

Page 22: ...placement or repair of defective parts and such other necessary maintenance and repair as may be required Normal wear and tear and parts damaged by abuse misuse negligence or accidents are specificall...

Page 23: ...k seal to tear SECOND STAGE REGULATOR AND HOSE 1 Cracks or heat damage to housing or cover 2 Faulty operation of bypass valve First Breath On AIR KLIC or override buttons 3 Dirt and debris in the outl...

Page 24: ...remove the rim nuts and screws 2 Gently separate the rims from the facepiece 3 Pull the silicone skirt away from the lens 4 Remove the old lens 5 Match one corner of the new lens with a corner of the...

Page 25: ...disconnect nipple 4 Listen to the second stage regulator it should not flow 5 Listen for leaks at all hose connections 6 Don the facepiece 7 Connect the facepiece to the second stage regulator and in...

Page 26: ...ation Specifica tion G 7 1 for Type 1 Grade D air having a moisture content expressed as dewpoint of 65 F or lower The cylinder shall be marked Fill With Compressed Air Only and shall meet applicable...

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ...www sperianprotection com...

Reviews: