background image

S-2018 

REV. D 

 

 

 

 

  

 

 

 

SENTINEL XL™ PAPR CBRN SYSTEM 

 

USER INSTRUCTION MANUAL 

 

FOR MODEL NO. S-5000 

 

 

 

  WARNING 

IMPROPER USE OF THIS RESPIRATOR MAY RESULT IN PERSONAL INJURY OR DEATH.  

IMPROPER USE INCLUDES, BUT IS NOT LIMITED TO, USE IN ATMOSPHERES 

CONTAINING UNKNOWN CONTAMINATES AND/OR UNKNOWN CONCENTRATIONS OF 

CONTAMINANTS, USE WITHOUT ADEQUATE TRAINING, DISREGARD TO THE 

WARNINGS AND INSTRUCTIONS CONTAINED HEREIN AND FAILURE TO INSPECT AND 

MAINTAIN THIS RESPIRATOR. 
THE RESPIRATOR IS NOT INTENDED FOR USE IN ATMOSPHERES WHERE THE 

IDENTITY AND/OR CONCENTRATION OF THE CONTAMINANT IS UNKNOWN. THIS MAY 

RESULT IN IMMEDIATE DANGER TO PERSONNEL. 
THIS RESPIRATOR DOES NOT SUPPLY OXYGEN AND MUST NOT BE USED IN OXYGEN-

DEFICIENT ENVIRONMENTS CONTAINING LESS THAN 19.5% OXYGEN. 

Summary of Contents for S-5000 Series

Page 1: ...WN CONCENTRATIONS OF CONTAMINANTS USE WITHOUT ADEQUATE TRAINING DISREGARD TO THE WARNINGS AND INSTRUCTIONS CONTAINED HEREIN AND FAILURE TO INSPECT AND MAINTAIN THIS RESPIRATOR THE RESPIRATOR IS NOT INTENDED FOR USE IN ATMOSPHERES WHERE THE IDENTITY AND OR CONCENTRATION OF THE CONTAMINANT IS UNKNOWN THIS MAY RESULT IN IMMEDIATE DANGER TO PERSONNEL THIS RESPIRATOR DOES NOT SUPPLY OXYGEN AND MUST NOT...

Page 2: ...ANGING BATTERY PACK 29 INSTALLING THE ALKALINE BATTERY ADAPTOR 30 REMOVING THE ALKALINE BATTERY ADAPTOR 33 STORAGE 35 TROUBLESHOOTING 35 CUSTOMER SERVICE INFORMATION 36 WARNING TRAINING IS REQUIRED BEFORE USE OF THIS RESPIRATOR FOLLOW THESE INSTRUCTIONS CAREFULLY THIS POWERED AIR PURIFYING DEVICE IS ONLY FOR USE IN SPECIFIC ATMOSPHERES AND UNDER CERTAIN CONDITIONS USE OF THIS RESPIRATOR WITHOUT PR...

Page 3: ...the packaging of this system immediately after purchasing it Refer to the inspection procedures in this manual which explain how to do so Failure to comply with this WARNING could lead to serious personal injury serious illness or death Note The Sentinel XL PAPR CBRN system has been tested against live chemical warfare agents agent stimulants and industrial chemicals under controlled laboratory co...

Page 4: ...malies occur 4 Failure to comply with this warning may lead to serious personal injury serious illness or death WARNING You must be fully familiar with the operation of Sentinel XL PAPR CBRN described within this manual prior to an emergency Emergency situations can be stressful To ensure that you obtain the maximum protection available from the Sentinel XL PAPR CBRN you must read and understand t...

Page 5: ...ILC Dover SENTINEL XL PAPR CBRN is a blower assisted air purifying respirator known as a Powered Air Purifying Respirator or PAPR The SENTINEL XL PAPR CBRN is comprised of the following components 1 Butyl Hood one size fit all P N S 2001 The hood is equipped with a large area visor allowing for an undisturbed field of vision an adjustable head harness that fits all head sizes a double skirt and an...

Page 6: ...proved to filter certain CBRN agents 5 Adjustable Waist Belt P N S 2007 Supports the blower assembly on the user s waist and is adjustable 6 Decon and Quick Release Belt and Clip P N S 4011 Optional This blower mounting option allows for quick and easy attachment or removal of the blower from the belt and also facilitates the cleaning disinfecting of biological materials from the belt with standar...

Page 7: ... 6 S 2018 REV D ILC DOVER SENTINEL XL PAPR CBRN SYSTEM WITH ADJUSTABLE WAIST BELT OR DECON AND QUICK RELEASE BELT AND CLIP Alkaline Battery Adaptor Decon and Quick Release Belt and Clip Not to Scale ...

Page 8: ... 7 S 2018 REV D ILC DOVER SENTINEL XL PAPR CBRN SYSTEM WITH BACKPACK AND ADJUSTABLE WAIST BELT Decon and Quick Release Belt and Clip OR Alkaline Battery Adaptor ...

Page 9: ...IS CONTAMINATED LEAVE THE CONTAMINATED AREA AND CLEAN CONTAMINANTS FROM YOUR HANDS BEFORE REACHING INSIDE THE HOOD IF YOU DISCOVER ANY OF THE WEAR AND DAMAGE DESCRIBED IN THE TROUBLESHOOTING SECTION OF THIS USER INSTRUCTION DISCARD COMPONENT AND REPLACE IT WITH A NEW ONE FAILURE TO DO SO MAY ADVERSELY AFFECT RESPIRATOR PERFORMANCE AND RESULT IN SICKNESS OR DEATH BEFORE USE THE WEARER MUST READ AND...

Page 10: ...RSON MUST READ AND UNDERSTAND THE INFORMATION IN THIS USER INSTRUCTION USE OF THE RESPIRATOR SYSTEMS BY UNTRAINED OR UNQUALIFIED PERSONS OR USE THAT IS NOT IN ACCORDANCE WITH THESE INSTRUCTIONS MAY ADVERSELY AFFECT RESPIRATOR PERFORMANCE AND MAY RESULT IN INJURY OR DEATH SERVICE LIFE OF CHEMICAL CARTRIDGE The useful service life of chemical Cartridge will depend upon the flow rate the specific typ...

Page 11: ...odify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions And or maintenance manuals for information on use and maintenance of these respirators R Some CBRN agents may not present immediate effects from exposure but can result in delayed impairment illness or death S Special or critical User s Instructions and or sp...

Page 12: ...iMnO2 Battery Pack Assembly S 4013 Optional Alkaline Battery Adaptor Batteries NOT included S 2009 Fast Battery Charger with Instructions Blower S 2002 Standard Blower Assembly Hood S 2001 Butyl Hood Assembly Waist Belt S 2007 Adjustable Waist Belt S 4011 Optional Decon and Quick Release Belt and Clip Backpack S 2008 Backpack Accessories S 2010 Flow Meter S 2018 Instruction Manual S 2023 Antimicro...

Page 13: ...k of the PAPR Connect the battery charger to an electrical outlet If charger is connected to an electrical outlet before connecting to a battery a solid green LED light indicates that the charger is operating properly When plugged into the battery the charger LED will turn solid red after a short time indicating that charging is underway Charge the battery for approximately 5 hours The charger s L...

Page 14: ...SUCH PUBLICATIONS AS ANSI Z88 2 1992 OR PURSUANT TO THE RECOMMENDATIONS OF AN INDUSTRIAL HYGIENIST USE OF A RESPIRATOR REQUIRES THAT A WRITTEN RESPIRATOR PROGRAM BE IN PLACE WHICH IS IN ACCORDANCE WITH THE OSHA RESPIRATORY PROTECTION STANDARD FOUND IN 29 CFR 1910 134 PRIOR TO USING ANY RESPIRATOR SYSTEM BEFORE USE THE USER MUST BE TRAINED BY THE EMPLOYER IN THE PROPER USE AND MAINTENANCE OF THE IL...

Page 15: ... use Screw the Cartridge into the threads until they are hand tight WARNING DO NOT OVER TIGHTEN CARTRIDGE OVER TIGHTENING MAY RESULT IN DISTORTION OR DISPLACEMENT OF THE SEAL AND ALLOW CONTAMINATED AIR TO ENTER THE RESPIRATOR HEADPIECE RESULTING IN INJURY OR DEATH 8 Check the airflow with the Flow Meter Ensure that the Cartridges are installed on the blower The blower can be installed on the waist...

Page 16: ...XIMUM USE CONCENTRATION MUC FOR THE RESPIRATOR HEAD PIECE OR ATMOSPHERE MAY NOT CONTAIN LESS THAN 19 5 OXYGEN THIS MAY RESULT IN IMMEDIATE DANGER TO PERSONNEL 9 Connect the Hood s Breathing Tube to the Blower Check that the breathing tube thread has the black rubber gasket seal present Check that the thread in the blower unit is in good condition and clear of foreign matter Screw the end of the br...

Page 17: ...daptor S 4013 Optional Batteries NOT included Battery charger with Instructions S 2009 Cartridge x 3 with Instructions S 2016 Flow Meter S 2010 Backpack S 2007 PAPR Hood S 2001 2 Insert the hood wrapped in its plastic bag into the backpack hood compartment and close the hood compartment using the zippers 3 Open the blower compartment cover roll it upwards and fasten the straps with the buckles exp...

Page 18: ...nto the three net receptacles on the backpack 6 Undo the strap buckles and unfold the blower compartment cover 7 Close the blower compartment using the zipper see picture below The backpack is now in stand by storage configuration Blower compartment zipper ...

Page 19: ...er to an electrical outlet A solid green LED light indicates that the charger is operating properly When plugged into the battery the charger LED will turn solid red after a short time indicating that charging is underway Charge the battery for approximately 5 hours While the battery is charging the red LED on the battery charger will be continuous The charger LED may flash green when charging is ...

Page 20: ...NSPECTION AND PERFORMANCE CHECK DO NOT USE THE RESPIRATOR SYSTEM UNTIL ALL NECESSARY REPAIRS HAVE BEEN PERFORMED AND THE RESPIRATOR SYSTEMS PASS THE PERFORMANCE CHECKS FAILURE TO DO SO MAY ADVERSELY AFFECT RESPIRATOR SYSTEM PERFORMANCE AND RESULT IN INJURY OR DEATH 3 If you are using the Non Rechargeable Battery or Alkaline Battery Adaptor continue onto Step 4 If there is no battery installed into...

Page 21: ... any part of the upper flat surface of the black cone is below the line on the flow meter check for o Blower malfunction o Improperly installed clogged or damaged Cartridge s o Low battery charge or battery malfunction o Improperly seated filter gasket s If the upper portion of the black cone is above the indication line on the flow meter the system is ready for use WARNING BEFORE ENTERING A HAZAR...

Page 22: ...bber gasket seal present Confirm that the thread in the blower unit is in good condition and clear of foreign matter Screw the end of the breathing tube into the blower unit until it is hand tight Ensure that there is not excessive twist on the hose If so loosen the breathing tube fitting where it attaches to the blower rotate the hose to eliminate the twist and retighten the fitting Do not over t...

Page 23: ...shape forehead size and shape and hair will affect the sizing of the product STEP 1 Protective wrap HEAD HARNESS SIZING INSTRUCTIONS Remove the protective wrap from the head harness and discard The Sentinel XL CBRN head harness is packaged pre sized to the XXL head adjustment To adjust the head harness to different size unsnap the female end and move the female adjustment snap to the proper male l...

Page 24: ...Fasten the female adjustment snap of the head harness into the appropriate sizing adjustment for the user If user is small or XS go to Step 4 These sizes are hidden in this picture behind the hood slot To adjust the head harness for small or XS tightly pull the webbing through the hood slot This will cause the hood slot material to bunch Fasten the female adjustment snap of the head harness into t...

Page 25: ...e shield You should feel the air entering into the hood Don the hood Place your thumbs on both ends of the padded part of the head strap with the visor facing your body Place the hood on your head the padded part of the head strap should be centered on your forehead The pictures below illustrate the positioning of the head harness on the forehead Incorrect Too high Correct Incorrect Too low Center...

Page 26: ...ng occurs remove the hood and adjust the head harness to a smaller size WARNING DO NOT REMOVE RESPIRATOR SYSTEM WHILE YOU ARE IN A HAZARDOUS ATMOSPHERE DOING SO MAY RESULT IN SICKNESS OR DEATH CONTAMINANTS WHICH ARE DANGEROUS TO YOUR HEALTH INCLUDE THOSE THAT YOU MAY NOT BE ABLE TO SEE OR SMELL LEAVE THE CONTAMINATED AREA IMMEDIATELY IF ANY PART OF THE SYSTEM BECOMES DAMAGED AIRFLOW INTO THE RESPI...

Page 27: ...nly persons wearing appropriate protective gloves and clothing should conduct respirator decontamination and removal You and the Sentinel XL PAPR CBRN must be decontaminated Be aware that touching or removing a contaminated Sentinel XL PAPR CBRN after it has been decontaminated could lead to skin contamination or exposure to toxic materials Once you have removed the Sentinel XL PAPR CBRN be sure t...

Page 28: ... CLEANING SOLUTIONS OR SOLVENTS MISUSE MAY ADVERSELY AFFECT RESPIRATOR PERFORMANCE AND RESULT IN INJURY OR DEATH WARNING AFTER DECONTAMINATION DISPOSE OF CARTRIDGE IN ACCORDANCE WITH FEDERAL STATE AND LOCAL ENVIRONMENTAL REGULATIONS DO NOT THROW AWAY DAMAGED OR UNUSABLE CARTRIDGE AS ORDINARY WASTE IMPROPER DISPOSAL OF CONTAMINATED CARTRIDGE MAY RESULT IN EXPOSURE TO CONTAMINANTS WHICH MAY CAUSE IN...

Page 29: ...AND MAY RESULT IN INJURY OR DEATH Examine the blower housing for cracks Replace if cracked or damaged Examine the outside of the battery pack for cracks Replace if damaged Cartridge Examine Cartridges for mechanical damage and deformities If found determine potential for contamination of user WARNING IF EXCESSIVE WEAR AND OR DAMAGE TO THE RESPIRATOR SYSTEM OR ITS COMPONENTS IS OBSERVED AT ANY TIME...

Page 30: ...ector parts and separate the battery pack from the blower 4 Connect the new battery pack 5 Slot the connector into its designated place in the blower as demonstrated 6 Close the battery pack Ensure that you do not pinch the battery leads when closing the battery pack 7 Ensure you hear an audible click when the battery pack latch locks into place 8 Operate normally Latch Connector Battery Pack Batt...

Page 31: ... battery aside for future use 4 Remove Alkaline Battery Adaptor from its original kit packaging Set aside the battery backing plate until Step 12 5 Remove the adhesive backing paper on the Alkaline Battery Adaptor hook and place the adaptor plate into the open cavity on the back of the blower with metal connectors facing out Note Do not separate Velcro hook from Velcro loop on the back of the Alka...

Page 32: ...or plate aside and use your thumbs to apply pressure across the Velcro hook white inside the blower to insure it is securely adhered 8 Install five Duracell D Cell batteries into the Alkaline Battery Adaptor NOTE USE ONLY DURACELL D CELL ALKALINE BATTERIES a Only remove and install the batteries when the Alkaline Battery Adaptor Plate is removed from the blower b Be sure to pay attention to the po...

Page 33: ...main outside as shown below and is used to remove the alkaline battery pack for exchange of battery cells or replacement with alternative battery options 10 Connect the new battery pack to the blower 11 Tuck the connector and wires into the open cavity at the top side of the blower as shown in the photo below Pull Strap Connector in stowed position ...

Page 34: ... battery life 15 When the low voltage alarm is heard immediately stop operation of the blower and replace the batteries with a new set of five Duracell D cell batteries REMOVING THE ALKALINE BATTERY ADAPTOR P N S 4013 1 Be sure to disconnect the battery connector and use the fabric pull strap to remove the Alkaline Battery Pack from the blower Velcro hook before removing the batteries 2 After remo...

Page 35: ...W D CELL BATTERIES AFTER THE LOW VOLTAGE ALARM IS INDICATED MAY RESULT IN INJURY OR DEATH DISPOSING OF DEPLETED BATTERIES 1 Remove Battery and dispose of properly Dispose of depleted or damaged batteries in accordance with state and local environmental regulations Do not throw away depleted or damaged batteries as ordinary waste WARNING DISPOSE OF DEPLETED OR DAMAGED BATTERIES IN ACCORDANCE WITH F...

Page 36: ...on Leave work area immediately switch to fully charged rechargeable battery or a new non rechargeable battery Replace Cartridges Remove plug and install third CBRN filter Switch to a different blower unit Blower gasket is raised twisted or has any visible surface defects Gasket is not properly seated into the blower and may produce a leak path Contact ILC Dover Customer Service Department immediat...

Page 37: ...HO 250 1 30 Hydrogen Cyanide HCN 470 4 7 30 Hydrogen Sulfide H2S 500 5 0 30 Nitrogen Dioxide NO2 100 1 ppm NO2or 25 ppm NO 30 Phosgene COCl2 125 1 25 30 Phosphine PH3 150 0 3 30 Sulfur Dioxide SO2 750 5 30 Sum of HCN and C2N2 Nitrogen Dioxide breakthrough is monitored for both NO2and NO The Breakthrough is determined by which quantity NO2 or NO reaches breakthrough first CUSTOMER SERVICE INFORMATI...

Page 38: ...ions d Defective products which the BUYER claims are covered by this warranty shall be returned to ILC prepaid and insured Reference paragraph 5 Upon ILC s determination that the defective products are covered by this warranty ILC will repair or replace at its option the defective products without charge to the BUYER and will ship the repaired or replacement products to the BUYER prepaid at ILC s ...

Page 39: ... of this document on any occasion shall not be considered a waiver or deprive ILC or Buyer as the case may be of the right thereafter to insist upon strict adherence to that term or any other terms of this document This document can be changed or terminated or its provisions waived only in a document signed by ILC and Buyer or their duly authorized agents Disclaimer of Certain Warranties Limitatio...

Page 40: ... 39 S 2018 REV D ...

Reviews: