background image

- 3- 

1. FEATURES 

Automatically records up to 16,000 (!) data points in the field 
along with time and date. These can later be downloaded to a 
computer via the meter’s RS232 port and the results viewed 
instantly on software which comes with the unit.  
 
The software also enables real time data logging directly from 
the meter to the computer. Simultaneously displays RH and 
ambient temperature readings and also reads type-K or J 
thermocouple probes.   
 
Features min-max, calendar /clock, selectable auto power off, 
and hold function. This well made unit is extremely accurate, 
has fast response times, a detachable probe, fold-out tripod 
and a large easy to read LCD.   
 
Comes ready to use in a protective foam lined carrying case 
complete with probe, software programs on two (2) CDs, 
RS232 computer connection cable, and batteries.   

 
 
 

Meter dimensions: 7 ¾" x 3" x 1½" (200 x 76 x 37 mm) 
Weight: 31 oz (515g) 
Probe handle diameter: 1" (26 mm) 
Cable length: 40" (1016 mm) 
Probe length: 8" (203 mm) 

 

Summary of Contents for 800022

Page 1: ...Datalogging Dew Point Thermohygrometer 800022 SPER SCIENTIFIC LTD...

Page 2: ...Data Logger 6 4 ADVANCED ADJUSTMENTS 7 A Check Remaining Available of Data Points 7 B Clear Memory 7 C Date Time Setting 7 D Sample Time Setting 7 E Auto Power Off Default Setting 7 F Temp Unit Defau...

Page 3: ...temperature readings and also reads type K or J thermocouple probes Features min max calendar clock selectable auto power off and hold function This well made unit is extremely accurate has fast respo...

Page 4: ...4 2 PANEL DESCRIPTION...

Page 5: ...t the PROBE PLUG 19 into the PROBE INPUT SOCKET 17 Slide the PROBE LOCK SWITCH 18 to the LOCK position Turn on the meter by pressing the POWER button 2 The readings are displayed as RH and C or F B De...

Page 6: ...ts in memory when the display indicates FULL Data Logger Procedures To momentarily display the set sampling time press the LOGGER button 8 once To change the sampling time see Sample Time Setting pg 7...

Page 7: ...ate time set screen Use the UP 5 DOWN 6 and ENTER 4 buttons to select the year month date hours minutes and seconds D Sample Time Setting Press the SET button 8 as needed to reach the sample time scre...

Page 8: ...Press the SEND button 7 for at least 2 seconds until the bottom right dis play shows Transmit mode Release the button The following screens flash alternately The meter can record up to 16 000 data poi...

Page 9: ...stor The 16 digits data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicates the following status D0 End Word 0D D1 D8 Display re...

Page 10: ...or small object into the SYSTEM RESET 13 while turn ing on the meter 9 OPTIONAL ACCESSORIES 840097 AC to DC 9V Adapter 840090 Water Resistant Instrument Pouch 840092 Bench Top Tripod 840093 Field Trip...

Page 11: ...s Type J 58 2012 F 100 1100 C Temperature Compensation Automatic for the humidity function and the type K J thermometer Type K J specification tests under the environment RF Field Strength less than 3...

Page 12: ...nt Sper Scientific product will be substituted if available This warranty does not cover probes batteries or damage resulting from accident misuse or abuse of the product In order to obtain warranty s...