7
6
Spectrum
TM
Hardness
Settings
Resin Volume (L)
13
18
25
100
6.5
9.0
12.5
120
5.4
7.5
10.4
140
4.6
6.4
8.9
160
4.1
5.6
7.8
180
3.6
5.0
6.9
200
3.3
4.5
6.3
220
3.0
4.1
5.7
240
2.7
3.8
5.2
260
2.5
3.5
4.8
280
2.3
3.2
4.5
300
2.2
3.0
4.2
320
2.0
2.8
3.9
340
1.9
2.6
3.7
360
1.8
2.5
3.5
380
1.7
2.4
3.3
400
1.6
2.3
3.1
420
1.5
2.1
3.0
440
1.5
2.0
2.8
460
1.4
2.0
2.7
480
1.4
1.9
2.6
500
1.3
1.8
2.5
600
1.1
1.5
2.1
Chart 1: Softener Water Capacity Chart
6.1. Operation in service mode
• Once your softener is running, you can view the time of day. By pressing “NEXT / ” for a few seconds, you will be
able to see the remaining capacity of soft water left.
• Once the capacity is expired, a flashing (CIRCLE) will be displayed on the screen, indicating a regeneration will be
programmed at the time determined in the program.
• Regeneration will cause the machine motor to run, creating a mechanical noise, this is normal.
6. Valve Operation
6.2. Adjust the Time of Day
• Push the “UP / ” and “DOWN / ” buttons to set the correct time.
NB.
The display of a valve using a low voltage transformer will blink during power failure. This blinking will end once
the programming has been restored.
6.3. Displaying the Remaining Volume of Water to be Treated (Metered System Only)
• Push the “NEXT / ” button to switch between the time of day and the remaining volume display.
6.4. Initiate a Regeneration
• Push the “regeneration /
R
” button for one second to initiate regeneration (the system will regenerate immediately for
a valve in “immediate regeneration mode” or at the next pre-set time for a valve in “delayed regeneration mode”).
• Push the “REGENERATION /
R
” button for 5 seconds to initiate regeneration immediately for a valve that is
programmed in “chronometric” or “volumetric” mode. This is to be used to flush the system after a long time such
as returning from holidays.
6.5. In Service
• T
he display will show the time of day during normal operation and will turn off after 3 minutes to conserve battery
life for battery operated models. The remaining volume of water to be treated can be displayed by pushing the
“NEXT ” button.