Freedom One eLift Lectern Troubleshooting Guide
0118408 Page 14 of 16
WARNING
Be sure the lectern movement does not interfere with objects or
people. Do not place any items under the lectern worksurface.
Symptom
Problem
Solution
Worksurface will
not operate
Loss of power
Be sure control box is plugged into a live circuit.
Loose electrical connections
Make sure all electrical connections are securely plugged into the control box.
See wiring diagram on p.10 for reference.
Object encountered under
the lectern worksurface
1.
Raise the worksurface by pressing the “up” button.
2.
Remove any items under the lectern worksurface.
3. Reset the lift mechanism (see below for procedure.)
Misaligned actuators due to
unbalanced loads
Solution #1
1. Unplug, then re-plug the power cord into a wall outlet.
2. Make sure all lift mechanism wire connections are in place and secure.
3. Remove
anything
located under the worksurface.
4. Press and hold the “Down” button to lower the worksurface to the lowest “work”
position until it stops moving.
5. Release the “Down” button.
6. Press and hold the “Down” button for 30 seconds. The worksurface will lower,
bottom-out, slightly rises, then stop moving. The worksurface must be completely
lowered before resuming operation.
Note: If the worksurface does not lower when doing this step, release the
“Down” button, and retry step 6.
7. Release the “Down” button. The lift mechanism has now been reset and the
worksurface can be adjusted normally.
Solution #2
1. Detach one of the actuators from the worksurface.
2.
Lower the lectern all the way down.
3. Re-attach the actuator to the worksurface.
Note: Not designed to be permanently
anchored to the floor. Optional glides are
available if a stationary lectern is needed.