background image

14215700-IG, Edition 7.0
January 2018, Original document

111

Field

Setting

IPEI (Optional)

If a specific handset is being subscribed for this user,
enter the IPEI number of the actual handset (the IPEI
number is readable from the label on the product). If this
is not the case, this field can be left empty and it will auto-
fill when the handsets subscribe.

Note

: A SIP REGISTER will not be sent before there is

an IPEI number present.

Note

: Programming of IPEI number into the system data-

base is necessary to enable service to the handset.

Note

: If handset sharing is used, the IPEI label will be a

link, that you can click on and link to a device. For more
information, see

"Adding Devices to Server" on

page 171

.

Access code (Optional)

Administrators can define a system wide or individual
access code as extra wireless security during the sub-
scription process.

Note

: Some 3rd party phones may need an Access code

to register to the Spectralink IP-DECT Server.

User - User

PIN code (Optional)(Only visible
if Handset Sharing License is
loaded)

Enter a code in the PIN code field for added security to
prevent other users from linking a handset with your user
profile.

The PIN code associates the user with a handset. For
more information, see

"User Sign-in/Sign-out" on

page 164

. See also Lync/Skype for Business Inter-

operability Guide.

Standby text (Optional)

Enter a standby text.

A standby text is a fixed label shown in the top left part of
the screen on the DECT handset when in idle state.

Note

: This feature is only available if Spectralink DECT

handsets are being used. If third party DECT handsets
are being subscribed, this feature is not supported.

Disabled (Optional)

If enabled, the user is disabled.

Note

: A disabled user cannot make calls from the hand-

set.

Spectralink IP-DECT Server 400/6500 Installation and Configuration Guide

Summary of Contents for IP-DECT SERVER 400

Page 1: ...14215700 IG Edition 7 0 January 2018 Original document Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 2: ...property of Spectralink and shall be neither reproduced in whole or in part without the prior written approval of Spectralink nor be implied to grant any license to make use or sell equipment manufactured in accordance herewith Spectralink reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases co...

Page 3: ...rview 21 Spectralink Handset Portfolio Overview 22 Total Configuration Overview 22 Server Comparison Matrix 23 Base Station Comparison Matrix 24 Configuration Overview Spectralink IP DECT Server 400 25 Configuration Overview Spectralink IP DECT Server 6500 27 Communication Ports Spectralink IP DECT Server 400 6500 28 Service Codes Spectralink IP DECT Server 29 Licenses 29 Licenses for Spectralink ...

Page 4: ... Installing the Spectralink IP DECT Base Station 47 Power Requirements for the Base Station 47 Base Station Appearence and Components 48 Base Station LED Indicators 50 Front Cover 50 LAN Port on Face Plate 50 Base Station Reset Button 50 Mounting the Base Station 51 Wall Mounted Vertical Installation RF Coverage 51 Installing the Spectralink DECT Repeater 53 Repeater Appearance and Components 54 R...

Page 5: ... and IP PBX Settings 77 To Configure SIP Settings 77 Configuring Wireless Server Settings 82 To Configure Wireless Server Settings 82 Configuring Media Resource Settings 88 Configuring Certificates if Using TLS 89 Handling Host and or CA Certificates 89 Configuring Clusters 90 Defining a Cluster for the Media Resource and Base Stations 91 Assigning Media Resources to Clusters 92 Assigning Base Sta...

Page 6: ...rmat 121 About System Management 122 Making a Back Up and Restore of System 123 To Make a Back Up or Restore of Configuration File 123 Updating Firmware 124 To Update Spectralink IP DECT Server Firmware 124 To Update Spectralink IP DECT Base Station Firmware 126 To Update Spectralink DECT Media Resource Firmware 129 To Update Spectralink DECT Handset Firmware Over The Air SUOTA 131 Restarting Syst...

Page 7: ...t Failure on the Master Spectralink IP DECT Server 6500 154 Failure on the Backup Spectralink IP DECT Server 6500 155 Configuring Corporate Phone Book Directory 156 To Get Phone Book Data through LDAP Server or CSV File 156 Example of LDAP Configuration 158 Example of CSV File Format 159 Handset Sharing 160 Handset Sharing Firmware Compatibility 162 Adding Handset Sharing License 163 Configuration...

Page 8: ...Redundancy 202 Configuration Provisioning 203 Configuration Import Export 205 Users List Users User 206 Users List Devices Device 209 Users List User Handset firmware update 210 Users Import Export 211 Administration Wireless Server 211 Administration License 212 Administration Media Resource Media Resource 0 213 Administration Base Station Base Station 0 214 Administration Clusters Cluster 0 215 ...

Page 9: ...e also provides you with information about l Web based Administration Page of the Spectralink IP DECT Server 400 6500 Spectralink DECT Media Resource and Spectralink IP DECT Base Station Important Information Before You Begin This guide assumes the following l that users have a working knowledge of the call handler s operations l that the call handler is installed and initialized and is working co...

Page 10: ...re information about synchronization and deploy ment refer to the guide available online at http sup port spectralink com products Provisioning For more information about provisioning refer to the guide available online at http sup port spectralink com products Spectralink Technical Bulletins Available online at http sup port spectralink com products Release Notes Document that describes software ...

Page 11: ...itting Diode LI Ion Lithium Ion Ni MH Nickel Metal Hydride Q Value Signal Quality Factor value An expression of the bit failure rate in the communication between the handset and a base station The value has a max of 64 equal to no bit errors measured LAN synchronization Method for synchronizing IP base stations over LAN Synchronization Over the Air OTA Method for synchronizing IP base stations ove...

Page 12: ...diated Power GAP Generic Access Profile HW PCS Hardware Product Change Status Hardware edition IP Internet Protocol IPEI International Portable Equipment Identity Serial number of the handset SN IWU Inter Working Unit Spectralink IP DECT Server Spectralink IP DECT Server400 6500 LAN Local Area Network MAC Media Access Control hardware address of a device con nected to a network MTU Maximum Transla...

Page 13: ...tocol SIP Session Initiated Protocol SW PCS Software Product Change Status Software edition TFTP Trivial File Transfer Protocol UDP User Datagram Protocol VoIP Voice over Internet Protocol WLAN Wireless Local Area Network WRFP Wireless Radio Fixed Part Wireless Repeater Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 14: ...nments Both handsets and base stations have an average power output of 10mW but can deliver a burst power output of 250mW Note The entire Spectralink 7000 Portfolio is built on DECT technology DECT Frequency Bands The following frequency bands are dedicated to DECT l EMEA Australia New Zealand 1G8 1880 1900 MHz l South America 1G9 1910 1930 MHz l USA Canada 1G9 1920 1930 MHz DECT 6 0 Note Because ...

Page 15: ...e server supporting SIP lines only Additional Spectralink IP DECT Base Stations can be added to the Spectralink IP DECT Server 400 to expand the covered area Note A license is required to enable the multi cell function For more information see Licenses for Spectralink IP DECT Server 400 6500 on page 29 All Spectralink IP DECT Base Station models can be used Up to 3 additional Spectralink IP DECT B...

Page 16: ... SfB support l Provisioning easy configuration and user administration l Supports Handset Firmware Update Over The Air SUOTA l Messaging via XML RPC Description Spectralink IP DECT Server 6500 The Spectralink IP DECT Server 6500 controls the wireless infrastructure It manages Spectralink DECT Media Resources Spectralink IP DECT Base Stations and the IP interface to the call hand ler The communicat...

Page 17: ... board speech channels MR32 l No radio part in Spectralink IP DECT Server 6500 requires base stations l Extremely scalable can be upgraded via purchase of licenses l Up to 4096 registered handsets 1024 simultaneous calls l Up to 1024 Spectralink IP DECT Base Stations requires multicast IP address 224 0 1 129 l Up to 3 modules per cabinet e g 1 x Spectralink IP DECT Server 6500 and 2 x Spectralink ...

Page 18: ... DECT Server 6500 and is the media termination point for incoming and outgoing calls Each Spectralink IP DECT Server 6500 contains one built in media resource The Spectralink IP DECT Server 6500 can support a total of 32 Spectralink DECT Media Resources Each Spectralink DECT Media Resource adds 32 voice channels The maximum number of sim ultaneous calls for a fully loaded system is 1024 calls at t...

Page 19: ...Spectralink IP DECT Server Reduces the amount of simultaneous calls to 12 x G 729 calls per Spectralink DECT Media Resource Description Spectralink IP DECT Base Station The Spectralink IP DECT Base Station is to be used with both Spectralink IP DECT Server 400 6500 and Spectralink DECT Server 2500 8000 The Spectralink IP DECT Base Station is designed with two internal antennas and supports antenna...

Page 20: ...voice channels It is wireless and does not need physical connection to the Spectralink IP DECT Server making it very easy to install The repeaters can be supplied with an external antenna making it possible to create radio coverage in a remote area without cabling to the rest of the installation The base station can support up to 3 repeaters System Capacity Overview Below you will find an overview...

Page 21: ... 32 Protocol supported SIP Simultaneous calls 32 Codecs supported G 711a G 711u Spectralink Server Solution Overview and Comparison Product Overview The Spectralink IP DECT Server 400 has a build in radio which acts like an Spectralink IP DECT Base Station with 11 speech channels Spectralink Digital DECT Base Stations are available in the following editions RFP4 and RFP5 4 speech channels and RFP6...

Page 22: ... Stations see Server Comparison Matrix on the next page and Base Station Comparison Matrix on page 24 Spectralink Handset Portfolio Overview For more information about the handsets see the relevant Handset User Guides Total Configuration Overview Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 23: ...l 8 channel Spectralink Digital DECT Base Station The Spectralink IP DECT Server 400 has a build in radio which acts like an Spectralink IP DECT Base Station with 11 speech channels External antenna can only be used with RFP 6 Spectralink Digital DECT Base Stations Spec tralink IP DECT Base Stations and Spectralink DECT Repeaters Spectralink IP DECT Server 400 6500 Installation and Configuration G...

Page 24: ...k base stations and the difference between them Only the Spectralink IP DECT Base Station and the RFP6 Spectralink Digital DECT Base Station are in production All other base stations seen here are no longer in production but are still widely used in the field Note The Spectralink Digital DECT Base Stations are not relevant to the Spectralink IP DECT Servers Spectralink IP DECT Server 400 6500 Inst...

Page 25: ...tralink IP DECT Server 400 Optional wireless repeaters can be used to extend the coverage of the Spectralink IP DECT Base Stations or the Spectralink IP DECT Server 400 itself External directional antennas are also optional and can be used with Spectralink IP DECT Base Stations or the Spectralink IP DECT Server 400 itself in physically complex environments which are challenging to cover with base ...

Page 26: ...sets are supported The Spectralink IP DECT Server 400 itself connects with the LAN via the ethernet interface and an optional 3rd party application can communicate over LAN with the Spectralink IP DECT Server 400 Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 27: ...ase stations or repeaters External antennas can also be used to create long distance coverage to bridge two locations belong ing to the same DECT system Spectralink DECT Repeaters can make use of external antennas as well and create a link from a remote location to the main coverage area There is no speech cov erage in the linking area which is symbolized by the light blue color All Spectralink 70...

Page 28: ...izes a number of different ports on the LAN See illustration below These ports MUST not be blocked by firewalls or other network equipment Tip Use the communication port illustration as a reference when configuring your network for a Spectralink IP DECT Server 400 6500 solution Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 29: ...ng ARI on Spectralink IP DECT Server on page 38 Licenses Licenses for Spectralink IP DECT Server 400 6500 Licenses can be purchased to enable additional features on the Spectralink IP DECT Server 400 6500 Some of the licenses are specific to the servers some are common for both For more information about obtaining and loading licenses see Ordering Licenses on page 33 and Loading Licenses on page 3...

Page 30: ...hannels Lync SRTP Multi Cell License 1407 5550 Allows Up to 30 users Up to 3 additional base sta tions Increases the number of chan nels enabled from 6 to 12 Includes Software Security Package SRTP TLS License bundle for Spectralink IP DECT Server 400 incl 12 users 12 speech channels Multi Cell License 1407 5520 Allows Up to 12 users Up to 3 additional base sta tions Increases the number of chan n...

Page 31: ...ows handsets to be shared among numbers and vice versa G 729 Codec License 1407 5480 Allows the use of the G 729 Audio Codec VoIP optimized codec The G 729 codec license can be bought to utilize codecs bey ond G 711 and G 726 It uses less bandwidth and is much used and very suitable for VoIP Use of less bandwidth also affects the Spectralink DECT Media Resource capa city Frequency Swap License for...

Page 32: ... Redundancy with ARI Swap License 1407 5260 Allows adding a backup server to a system Software License for Master Spectralink IP DECT Server 6500 Reduandancy 1407 5250 Allows adding a backup server to a system User License for Spectralink IP DECT Server 6500 30 users 1407 5200 Allows for up to 30 users User License for Spectralink IP DECT Server 6500 150 users 1407 5210 Allows for up to 150 users ...

Page 33: ...ning Inter face License for Spectralink IP DECT Server 6500 1407 5200 Allows for provisioning of firm ware for l IP DECT base stations l Media resources l Handsets Ordering Licenses 1 Send your Purchase Order PO including the software part number and the number of licenses needed to Spectralink Order Management via EMEA and APAC emeaom spec tralink com or NALA nalaom spectralink com 2 When your or...

Page 34: ...en click License 2 Copy the provided license key from your email paste it in the License field and then click Load 3 Reboot the server to activate the license For information about deleting a license see Deleting Licenses on page 143 Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 35: ...ll ventilated l be within the temperature ranges of 10 C and 40 C 50 F and 104 F l be between 20 and 80 non condensing relative humidity Note The installation area must be of sufficient height from the floor to prevent water damage 1U rack space in a 19 cabinet or respective space on the wall when mounting the Spec tralink IP DECT Server 6500 in vertical position on a wall For more information abo...

Page 36: ... 3af class 1 device Use a standard PoE adapter or a PoE enabled port on a switch adhering to PoE 802 3af when con necting the base station to a PoE power source Use an 8V DC power supply when using a power supply as power source For more information about installing the Spectralink IP DECT Base Station and Spectralink DECT Repeater see Installing the Spectralink IP DECT Base Station on page 47 and...

Page 37: ... The AC is a customer defined optional subscription pin code of a maximum of eight digits for the individual handset The AC can be used when connecting the handset to the server l Repeaters Mark each repeater with the number of the related base station This way you can easily con figure the system on site l Handsets To use the handsets you must first install the radio infrastructure e g base stati...

Page 38: ...a User Each User must hold information about extension number the handset s IPEI number and its registration credentials for the PBX This information is used to link the subscribed handset to the PBX which is the same as a line registration A Users profile holds subscription data and registration data For more information see Registering Users and Subscribing Spectralink DECT Handsets on page 110 ...

Page 39: ...IP DECT Base Station and server For more information about appearance and components Reset Button and mounting see Installing the Spectralink IP DECT Base Station on page 47 Note Before you install the equipment ensure that a site planner defines the locations of the Spectralink IP DECT Server Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 40: ... Spectralink DECT Media Resource with the Spectralink IP DECT Server 6500 is optional Installation of a media resource will augment the number of sim ultaneous voice calls supported by a stand alone server The Spectralink IP DECT Server 6500 comes with one build in media resource Before you install the equipment ensure that a site planner defines the locations of the Spectralink IP DECT Server 650...

Page 41: ...nitializes The indicator is on when the Spectralink IP DECT Server 6500 Spectralink DECT Media Resource is operating LED Indicator Meaning Steady green OK and idle Slow green flashing OK and active voice call Fast green flashing Active in operation with the maximum active connections busy Slow red flashing Missing media resource or base station if it is a media resource missing connection to Spect...

Page 42: ...to factory default settings original IP settings and empty user data base and restarts the system Firmware ver sion is not affected Mounting in a Rack The Spectralink IP DECT Server 6500 Spectralink DECT Media Resource is mountable in a rack 1 Mount the two wings with the screws If you are mounting the Spectralink IP DECT Server 6500 on a wall twist the wings 90 degrees 2 Mount the cabinet in the ...

Page 43: ...els and is purchased seperately Below is an image of the Spectralink IP DECT Server 6500 cabinet The Spectralink IP DECT Server 6500 itself resides to the far left which is standard and the two optional Spectralink DECT Media Resources reside in the middle and to the far right Note It is possible to have cabinets with Spectralink DECT Media Resources only but they can only be used in conjunction w...

Page 44: ...esource 1 Remove the top cover from the cabinet 2 Unpack the media resource board 3 Cut a hole for the RJ45 network connector in the front foil of the cabinet 4 Mount the media resource board in the cabinet with three screws Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 45: ... 7 0 January 2018 Original document 45 5 Prepare the media resource power connector 6 Connect the power cable to the media resource power connector Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 46: ...14215700 IG Edition 7 0 January 2018 Original document 46 7 Close the cabinet again Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 47: ...uildings is 75 meters 245 feet The coverage depends on the construction of the building architecture and the choice of building materials Power Requirements for the Base Station The Spectralink IP DECT Base Station uses l Power over Ethernet PoE 802 3af l Maximum power supply consumption is 3 0W IEEE 802 3af class 1 device Use a standard PoE adapter or a PoE enabled port on a switch adhering to Po...

Page 48: ...nce and Components Below you will find a description of the base station appearance and components IP DECT Base Station rear 1 Holesfor wallmounted screws 2 Connection to LAN IP DECT Base Station front 1 LED Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 49: ...IG Edition 7 0 January 2018 Original document 49 IP DECT Base Station 1 Reset button 2 LINK ActivityIndicator 3 ETH port power supplybyPoE Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 50: ...dy red Reset shutdown in progress Steady red for 5 seconds followed by fast red flashing Reset to factory settings LAN Port on Face Plate LED Indicator Meaning LINK Indicator yellow Link layer software has established connection LINK Indicator green flashing Activity Base Station Reset Button You can restart or reset the base station by pressing the Reset button on the bottom of face plate of the ...

Page 51: ...n RF Coverage For best RF coverage the base station must be mounted vertically on walls The antennas must always be kept perpendicular to the floor Caution l The base station must not be installed at any angle other than vertical l Do not mount the base station on soft surfaced walls such as those covered with canvas metal or sponge like materials How to Wall Mount the Spectralink IP DECT Base Sta...

Page 52: ...ed screws 2 RJ45 port 3 Connect the RJ45 plug to the ethernet connector 4 After installing the base station you need to power it up For more information see Power Requirements for the Base Station on page 47 Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 53: ...equipment ensure that a site planner defines the location of the repeaters The coverage depends on the construction of the building and the choice of building materials The repeater does not add channels It only adds additional coverage area For installations the following items should be present in every box containing a Spectralink DECT Repeater l Spectralink DECT Repeater l Mounting template l ...

Page 54: ...nents Below you will find a description of the repeater appearance and components DECT Repeater bottom DECT Repeater rear 1 RJ9 port 1 Holesfor wallmounted screws 2 Externalantenna connector DECT Repeater front 1 LED Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 55: ...placed within the coverage area of an already installed repeater l When placed outside the coverage area of a base station or repeater using an external antenna Note The repeater does not add channels It only adds additional coverage area Environmental Considerations l Do not install a device near metal objects and steel constructions l Do not position devices in ducts plenums or hollow spaces use...

Page 56: ...ble to the RJ9 port on the bottom of the repeater For repeaters with external antenna connect the external antenna cable to the antenna con nector on the rear side of the repeater and in the same way on the external antenna 2 Mount the repeater on the wall using the anchors and screws accompanying the product 3 After installing the repeater you need to power it up The power supply for the repeater...

Page 57: ...Service Tool Programming the Spectralink DECT Repeater with the Service Tool The Service Tool is the tool you access from your desktop and use for repeater programming hand set adjustment and software download to the handset and repeater For more information about pro gramming the repeater with the Service Tool refer to the Help File in the Service Tool The Service Tool identifies the type of repe...

Page 58: ... station 64 l Base to synchronize on RPN of base station Second Repeater l RPN of base station 128 l Base to synchronize on RPN of base station Third Repeater l RPN of base station 192 l Base to synchronize on RPN of base station Numbering of Repeaters in a Repeater Jump Configuration First Repeater in Chain l RPN of base station 64 l Base to synchronize on RPN of base station Second Repeater in C...

Page 59: ...k DECT Repeater The Spectralink DECT Repeater is automatically configured to the external antenna when connected Below is an example of using a Spectralink DECT Repeater with External antenna The radio link way must be stable and free of moving objects The RSSI level of the main system at the Spectralink DECT Repeater placed remotely must not be lower than 75 Note Inside the area named radio link ...

Page 60: ...ions External Antenna Electrical Properties l Frequency range 1880 1930 MHz l Impendence 50 Ω DC path to ground l Polarization RHCP l Gain 7 5 8 0 dB l 3 dB beamwidth horizontal 62 l 3 dB beamwidth vertical 62 l Front to back ratio 8 dB l Return loss 15 dB l Connector SMB male l One meter cable included Environmental Conditions l Operating temperature 20º 55º C 4º 131º F l Storage temperature 40º ...

Page 61: ... For more information see Installing the Spectralink IP DECT Base Station on page 47 4 Change the IP address of the Spectralink IP DECT Base Station For more information see To Configure a Dynamic IP address on page 70 5 Configure the Spectralink IP DECT Base Station with the address of the Spectralink IP DECT Server For more information see Assigning Server Address to Spectralink IP DECT Base Sta...

Page 62: ...dancy server handset sharing phone book and MSF messaging can also be part of further configuration For more information see l Configuring Media Resource Settings on page 88 l Configuring Clusters on page 90 l Configuring Redundancy on page 147 l Configuration of Handset Sharing on page 163 l Configuring Corporate Phone Book Directory on page 156 l Messaging Over MSF on page 144 Spectralink IP DEC...

Page 63: ...ubnet mask DNS server Time server and other IP parameters from the DHCP server l entered manually through web based Administration Page Configuration General General Configuration page Using manual network configuration the IP addresses and other networking parameters are entered manually through the web based Administration Page Recommended Network Configuration When configuring a Spectralink IP ...

Page 64: ... configured using DHCP it is necessary to assign a reservation for the device on the DHCP server Assigning DHCP Server Options This section provides you with information on basic network configuration of the Spectralink IP DECT Server 400 6500 solution and the web based Administration Page You can provide information about the static IP address of Spectralink IP DECT Server 400 6500 in the DHCP se...

Page 65: ...Serial number e g Spectralink IP DECT Server6500 8442621 Below is an example of using UPnP to discover Spectralink IP DECT Server 6500 l Double click the icon to access the web based Administration Page of the Spectralink IP DECT Server 6500 Assigning DHCP Server Reservations If the Spectralink IP DECT Server Spectralink DECT Media Resource is configured using DHCP it is necessary to assign a rese...

Page 66: ... 0 1 Password The Spectralink IP DECT Server Spectralink DECT Media Resources and Spectralink IP DECT Base Stations are delivered with a default user name and password l Default user name of the system is admin l Default password of the system is admin Note l After five successive failed login attempts the web based Administration Page will be locked for the next five minutes l After being idle fo...

Page 67: ...ase Station consists of menus and sub menus First you click a menu and then you click one of the submenus to display the relevant page Spectralink IP DECT Server The web based Administration Page is used to configure the different solution components of the Spectralink IP DECT Server For an overview and description of parameters on the different pages see Parameter Overview on page 184 Spectralink...

Page 68: ...k IP DECT Base Station should connect l Radio synchronization Over The Air l Status Information l Firmware update Spectralink DECT Media Resource The web based Administration Page of the Spectralink DECT Media Resource can be used in the fol lowing situations l Configuration to specify to which Spectralink IP DECT Server the Spectralink DECT Media Resource should connect l Status Information l Fir...

Page 69: ... Recommended Network Configuration on page 63 Note As the Spectralink IP DECT Server is a critical part of the SIP infrastructure it is highly recommended that you do not use DHCP Using a static IP address for the Spectralink IP DECT Server is the preferred method If the device is configured using a static IP address it is possible to assign options to the DHCP server making it extremely easy to c...

Page 70: ...address for the base stations from the web based Admin istration Page 1 Click Configuration and then click General 2 On the General Configuration page enter the following data Field Setting General Configuration Pv4 Method Select DHCP assigned Note Selecting DHCP all other network settings are provided auto matically 3 Click Save Spectralink IP DECT Server 400 6500 Installation and Configuration G...

Page 71: ...ect Use Static IP Address to configure a static IP address Note When using a static IP address it is also neces sary to configure other network settings below such as DNS and NTP settings For more information see also Recommended Network Configuration on page 63 IP addr Optional Enter the IP address of the Spectralink IP DECT Server Netmask Optional Enter a new network mask Contact your system adm...

Page 72: ...gth must be separated by Default gateway Optional Enter IP address of the default gateway The default gate way serves as an access point to another network General Configuration Ethernet VLAN Optional It is possible to enter the VLAN Identifier VID according to IEEE 802 1Q specifying the VLAN to which the device belongs Note If this setting is used network access from outside the VLAN is no longer...

Page 73: ...ime zone setting The string must be in POSIX time zone format General Configuration UPnP Enabled Optional Enabled by default If enabled the device is UPnP dis coverable UPnP is an acronym for Universal Plug and Play If the IP address of the device is unknown e g forgotten or DHCP assigned UPnP can be used to easily identify the IP address of the device Note If My Network Places in Windows is setup...

Page 74: ...ll only apply to the server and media resource Default value all General Configuration SNMP Enabled Optional If enabled access to the SNMP is allowed and the server will respond to SNMP requests Community Optional SNMP Community name public The server will respond to requests from a manager in this community Trap host Optional Address of SNMP trap host to which SNMP traps are sent Trap community O...

Page 75: ...sword requirements Optional If enabling strict password requirements the device can be configured to enforce certain security rules and nam ing conventions For more information see Strict Pass word Requirements on the next page Note Strict password requirements can only be disabled by a factory reset Configuration Factory Reset Password expiration Optional Select when you want the password to expi...

Page 76: ...m full system backups Note Once enabled this setting can only be disabled by a factory reset that will remove all configuration and user data 3 Click Save Strict Password Requirements When using strict password requirements the password of the web based Administration Page must meet the following requirements l Minimum length of 8 characters l Must contain characters from at least two of the follo...

Page 77: ...g The default local port number is 5060 Transport Transport mechanism used for SIP messages Possible values UDP TCP or TLS Note If TLS is used as SIP Transport Method it is neces sary to import host certificate and CA certificates into the server For more information see Configuring Cer tificates if Using TLS on page 89 DNS method Used for looking up the destination of SIP messages Possible values...

Page 78: ...e 70 Client transaction timeout msec Client transaction time out This controls timer B and F as specified in RFC3261 Increase this to eliminate time out errors or decrease it to reduce fail over time Default value 16000 msec SIP type of service TOS Diff serv TOS Diffserv used for SIP signaling Entered in decimal Default value 96 SIP 802 1p Class of Service This is the 802 1p PCP and must be betwee...

Page 79: ...ult value 100 URI The URI or IP address of the proxy SIP Configuration Authentication Default user Optional Default user name used for SIP authentication Note If no handset specific authentication user name password is configured handsets registered on theSpec tralink IP DECT DECT Server will use the default user name password Default password Optional Enter password Realm Optional The realm prese...

Page 80: ...or RTP Media signaling entered in decimal Default value 184 Media 802 1p Class of Service This is the 802 1p PCP and must be between 0 and 7 The setting requires VLAN tagging Default value 5 Port range start Port range start for local RTP ports Default value 58000 Codec priority Define the priorities of codecs Possible values PCMU PCMA G 726 or G 729 SDP answer with preferred codec Optional Specif...

Page 81: ...ation password will be used SIP Configuration Call status Play on hold tone Optional If enabled on hold tone is received in remote end when placed on hold Note This might conflict with Music on Hold Provide Music on Hold Optional If enabled Music on Hold is played for the remote end Display status messages Optional If enabled call status messages are received in the hand set key ends overlap diali...

Page 82: ...l be authen ticated Encrypt voice data Optional Encryption of voice data packets transmitted via DECT Possible values Disabled Enabled or Enforced non GAP Default value Disabled System access code Optional System wide DECT access code The access code is from 0 8 decimal digits Note Individual user access code AC has pre cedence over system access code Send date and time Optional If enabled date an...

Page 83: ...resource supports encryption Wireless Server Configuration Base stations Allow new Optional If enabled new base stations are allowed to connect to the server Add new as active Optional If enabled new base stations will become active when added Otherwise they must be activated manually under Administration Base Station Base Sta tion page Require encryption Optional If enabled the connection between...

Page 84: ...s routers Default value 1 Default sync type Optional This setting controls the default sync type for new base stations connecting to the server Possible values Free running Radio or LAN Note Selecting Free running will configure each base station as a sync master For more information see also Synchronization and Deployment Guide Default value Radio LAN sync transport protocol Only visible if licen...

Page 85: ...se is loaded Disable this if handset sharing is not to be allowed For more information about using handset sharing and configuring handset login see Handset Sharing on page 160 Handset login Only visible if Skype for business License is loaded If enabled user credentials can be entered on the handset and no user configuration is required on the server Use long key press 9 to login System depend an...

Page 86: ... Optional Enable call forward unconditional by dialing this code 21 including the desired extension E g 21 Note It is possible to change the code 21 on the Spectralink IP DECT Server to fit your standard For more information see the relevant documentation available at http support spectralink com Call forward unconditional dis able Optional Disable call forward unconditional by dialing this code 2...

Page 87: ...ed allow DECT Server to use this long key press for phone book Enable Long Press Key6 Undefined Optional If enabled allow DECT Server to use this long key press Enable Long Press Key7 Undefined Optional If enabled allow DECT Server to use this long key press Enable Long Press Key8 Undefined Optional If enabled allow DECT Server to use this long key press Enable Long Press Key9 Hand set Sharing Opt...

Page 88: ...nistration Page 1 Click Configuration and then click Media Resource 2 On the Media Resource Configuration page enter the following data Field Media Resource Configuration Media resource Enable internal If enabled the internal media resource will start up and connect If disabled CPU power is increased Additional media resource will take over then if installed Default value Enabled 3 Click Save Spec...

Page 89: ...ain Overview of device certificates These are non change able Examples of device certificates are Device certificate SpectraLink Issuing CA Spectralink Inc and Spec traLink Root CA Spectralink Inc Certificates Host certificate chain Certificate file Click Browse to find the relevant host certificate file crt file Key file Click Browse to find the relevant key file pem file Password Optional Enter ...

Page 90: ...s are used in situations where there are multiple locations physically separated using the same system ARI Clusters help keep the RTP stream local when possible internal calls l In a site with two locations a media resource can be placed in one of the locations and an amount of base stations can point to that specific media resource if a cluster has been created Creating a cluster for a location w...

Page 91: ... 1 Click Administration and then click Clusters 2 On the Clusters page click New 3 On the Cluster 0 page enter the following data Field Cluster General Name Enter a name for the cluster E g Site A Site B Site C 4 Click Save You can now assign the base stations and media resources to use the relevant clusters Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 92: ...P address of the media resource Description Optional Enter a description E g Serial 008490046 Cluster Default value Default It is possible to cluster devices that are located at the same location To assign a cluster to the media resource select the rel evant cluster from the list For information about defining clusters see Configuring Clusters on page 90 Disabled Optional If enabled the media reso...

Page 93: ...lue Default It is possible to cluster devices that are located at the same location To assign a cluster to the base station select the relevant cluster from the list For information about defining clusters see Configuring Clusters on page 90 Disabled Optional If enabled the base station will be disabled Note If Add new as active is enabled Configuration Wireless Server Base stations then this will...

Page 94: ... settings for synchronization are loc ated under Configuration Wireless Server Base stations For more information see Synchronization and Deploy ment Guide Auto radio sync deployment only Optional If enabled the base station will be auto synchronized while deploying the system Note This must only be used while deploying the sys tem Primary radio sync RPN Optional RPN identifying the base station u...

Page 95: ...14215700 IG Edition 7 0 January 2018 Original document 95 4 Click Save 5 Click Reboot base station Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 96: ...uld be discovered by UPnP For more information see Dis covering the Spectralink IP DECT Components via UPnP on page 65 Manually IP DECT Server Address Configuration for Base Stations To configure the server address manually through the web based Administration Page of the base station 1 Open a browser and enter the static IP address of the base station 2 Click Configuration and then click Base Sta...

Page 97: ...resource 1 Open a browser and enter the static IP address of the media resource 2 Click Configuration and then click Media Resource 3 On the Media Resource Configuration page enter the following data Field Setting Media Resource Wireless Server Host Server Enter the address of the Spectralink IP DECT Server that the media resource must connect to 4 Click Save 5 Click Reboot to enable the configura...

Page 98: ...ation via LAN and radio can be combined in the same DECT installation Even when a base station is configured to synchronize via LAN the base station trans mits the signal required for synchronization via radio Therefore base stations syn chronizing via radio can retrieve their synchronization signal from a base station synchronizing via LAN If configured as Radio LAN Gateway an IP DECT Base Statio...

Page 99: ...en click Base Station and then click on the relevant base station 2 On the Base station configuration page enter the following data Field Base Station General IP address Read only Current IP address of the base station Description Optional Enter a description E g Serial 008472982 RPN Radio Part Number of the base station Cluster Default value Default It is possible to cluster devices that are loca...

Page 100: ...nchronization Type This setting controls the synchronization type used for the specific base station DECT radio Possible values Free running Radio LAN or Radi o LAN Gateway Select Free running if you want to configure this base station as sync master Otherwise select either Radio LAN or Radio LAN Gateway depending on the syn chronization method Default value Radio Note System wide settings for syn...

Page 101: ...sible if more than one base station on the system RPN RSSI dB Offset Possible to see the RSSI values of the base stations the selected base station is synchronizing on Primary syn c Secondary Alternative sync For more information about RSSI values see Syn chronization and Deployment Guide 3 Click Save 4 Click Reboot base station Spectralink IP DECT Server 400 6500 Installation and Configuration Gu...

Page 102: ...ECT radios via the LAN PTPv2 is defined in the standard IEEE 1588 2008 and a brief introduction can be found here http en wikipedia org wiki Precision_Time_Protocol PTPv2 is based on a master slave architecture where the active master is automatically selected among the base stations Each network segment will have one active master and the remaining base stations will be slaves If the current mast...

Page 103: ...tional System wide DECT access code The access code is from 0 8 decimal digits Note Individual user access code AC has pre cedence over system access code Send date and time Optional If enabled date and time will be sent to the handsets when a call is terminated Default value Enabled System TX power Optional Used for controlling reducing the output power of all connected base stations supporting p...

Page 104: ...ve Optional If enabled new base stations will become active when added Otherwise they must be activated manually under Administration Base Station Base Sta tion page Require encryption Optional If enabled the connection between the base station and the Spectralink IP DECT Server is required to be encrypted Note Enabling this will only allow base stations with firmware PCS17Fa or newer to connect I...

Page 105: ...zation and Deployment Guide Default value Radio LAN sync transport protocol Only visible if license loaded The protocol transport layer used by PTP for LAN sync Possible values Ethernet IPv4 or IPv6 For more information about using LAN syn chronization see LAN Based Synchronization License Required on page 102 LAN sync type of service TOS Diff serv Only visible if license loaded TOS DiffServ value...

Page 106: ... see Configuring Handset Login on page 164 and Handset User Guides Wireless Server Configuration Application interface Username Enter username required to access the application interface Max length 31 characters New password Optional Enter password required to access the application interface Max length 31 characters New password again Optional Confirm password required to access the application ...

Page 107: ...list Wireless Server Configuration MSF Enable Long Press Key0 Phone book Optional If enabled allow DECT Server to use this long key press for phone book Enable Long Press Key1 Phone book Optional If enabled allow DECT Server to use this long key press for phone book Enable Long Press Key2 Phone book Optional If enabled allow DECT Server to use this long key press for phone book Enable Long Press K...

Page 108: ...erver to use this long key press Enable Long Press Key9 Hand set Sharing Optional If enabled allow DECT Server to use this long key press for handset sharing For more information see Handset Sharing on page 160 and User Sign in Sign out on page 164 Click Save Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 109: ...onized Primary Sync Master l If marked with Searching not in sync with any radio unit l If marked with Unknown not connected base station removed from installation 3 View RFP and RPN numbers Note When you click a base station in the list you can check the RSSI values of the base sta tions it is synchronizing on Primary sync Secondary Alternative sync For more inform ation about synchronization and...

Page 110: ...ription of the handset is not possible Registering a User To register users you use the web based Administration Page of the server To Register Create a New User 1 Click Users and then click List Users 2 Click New to create a new user 3 On the User page enter the following data Field Setting User DECT device Model After registration of user and subscription of handset this field will contain infor...

Page 111: ...s security during the sub scription process Note Some 3rd party phones may need an Access code to register to the Spectralink IP DECT Server User User PIN code Optional Only visible if Handset Sharing License is loaded Enter a code in the PIN code field for added security to prevent other users from linking a handset with your user profile The PIN code associates the user with a handset For more i...

Page 112: ...dministration of users within the Spectralink IP DECT Server Authentication user Optional Enter the user ID of the end user E g JohnDoe or 5208 Note The user name will override the Default User field under SIP Configuration Priority 1 Authentication user set for individual users 2 Authentication user set in server SIP settings 3 User name set for individual users Authentication password Optional E...

Page 113: ...e the Spectralink IP DECT Server to allow for subscription If the sys tem does not allow subscription it is not possible to subscribe the handset For more information see Configuring Wireless Server Settings on page 82 You subscribe a handset by creating a login Menu Settings Advanced Login For more information see the relevant Handset User Guides Spectralink IP DECT Server 400 6500 Installation a...

Page 114: ...ort of user data can be performed from web based Administration Page Users Import Export Note Handset programming and firmware maintenance can be done using the Handset Man agement Tool The Handset Management Tool can be downloaded from http sup port spectralink com products For more information see Handset Management Tool User Guide Handset firmware can also be updated through provisioning For mo...

Page 115: ...nt user name extension l Displayname name presenting the user in outgoing calls l IPEI IPEI number of handset l Handset Handset model l Firmware firmware version in handset l Subscription indicates if handset is subscribed to a Spectralink IP DECT Server l Registration indicates if handset is registered to a SIP server l Latest activity last time the server has been in contact with the handset o L...

Page 116: ...e information see Registering a User on page 110 To View or Change Handset User Configuration You can view or change all the user configurations of the wireless system through the web based Administration Page 1 Click Users and then click List Users The list will show all entries as default It is possible to search for information 2 Click on the relevant user to change user configurations such as ...

Page 117: ...user on the server and prevent this user from making calls from the handset 1 Click Users and then click List Users 2 On the User List page select the relevant user s from the list 3 Click either Enable or Disable To Delete Deregister User 1 Click Users and then click List Users 2 On the User List page select the relevant user s from the list 3 Click Delete 4 Click OK to confirm To Re register Use...

Page 118: ... time within the next 24 hours Update load Default value Medium Select relevant upload capacity You can select between Low Medium or High The load corresponds to the number of maximum sim ultaneous updates Low 1 handset at a time Medium 5 handsets per media resource High 17 handsets per media resource Firmware file The firmware file can be either a previously uploaded default firmware file or a ne...

Page 119: ...w Medium or High The load corresponds to the number of maximum sim ultaneous updates Low 1 handset at a time Medium 5 handsets per media resource High 17 handsets per media resource Firmware file The firmware file can be either a previously uploaded default firmware file or a new firmware file chosen A new firmware file must be a valid firmware file with the exten sion bin Select either Default or...

Page 120: ...TF 8 ISO IEC 8859 1 or Window 1252 Note The encoding depends on the software that was used to generate the CSV file If you use Microsoft Win dows you will probably select Windows 1252 Import Export Users Export user data CSV format If you want to save the user data file in CSV format click Save The CSV format can be imported back into the server XML format If you want to save the user data file in...

Page 121: ... displayname authenticate user authenticate password disabled Note If you want to leave out some of the information e g standbytext you must keep the com mas e g IPEI access code username domain displayname authenticate user authenticate password disabled For more information about importing user data see Import Export of Users or Delete Users on page 119 Note It is not possible to import handset ...

Page 122: ...and statistics l change administration password l reset the system l block new calls during firmware update l Import Export configuration file l delete license l configure different system settings for more information see Configuration Steps Overview on page 61 Note System software can also be updated through provisioning Besides provisioning of the server configuration file you can also provisio...

Page 123: ...P DECT Server which is useful in case of problem solving or if you want to do a system restore To Make a Back Up or Restore of Configuration File 1 Click Administration and then click Backup 2 On the System Backup page enter the following data Field Setting System Backup Backup Full system backup Click Save A full system backup is performed and saved as fullbackup tar System Backup Restore Full sy...

Page 124: ...Management Cradle and download of Handset Management Tool is required Physical access to each Spectralink DECT Handset to be updated is also required For more information about the Handset Management Cradle and Handset Management Tool see Handset User Guides and Handset Management Tool User Guide l Provisioning license required For more information see Provisioning Guide Note Before updating syste...

Page 125: ...o make further changes before the update is started 4 Optionally you can block new calls during a firmware update by clicking Administration and then clicking Wireless Server On the Wireless Server page under Service Status click Block 5 Click Reboot now or Reboot when idle Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 126: ...e is uploaded as default for all base stations and media resources recommended For the files to be updated in the base station this must be executed either through manual update or automatic update Build Information about the build number of default firmware file if a default firmware file has been uploaded Update base station firmware Automatic Enable Optional Default value Disabled Enable this i...

Page 127: ... Optional The firmware file can be either a previously uploaded default firmware file or a new firmware file chosen A new firmware file has to be a valid firmware file with the extension bin Select either Default or Upload Start base station No The index number of the first base station to be updated You can check base station numbers under Administration base stations IP Base Stations End base st...

Page 128: ...ry 2018 Original document 128 Note If Automatic update is not enabled Spectralink IP DECT Base Stations can be rebooted manually after they have been updated Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 129: ...nter the following data Field Setting Update media resource firmware Default PCS Information about default firmware file version PCS if a firm ware file has been uploaded Note Once uploaded default firmware will remain on the server until overwritten Note If the Use firmware as default check box on the Update firmware page is enabled Firmware Wireless Server or Configuration Provisioning Firmware ...

Page 130: ...n see Pro visioning Guide Force Optional When Force is enabled the media resources will be updated at the selected Start time If Force is disabled the media resources will be updated when they become idle after the selected Start time Start time Optional Default value Immediately If you want to upload later select an appropriate time within the next 24 hours Click Save Update media resource firmwa...

Page 131: ...ey have been updated To Update Spectralink DECT Handset Firmware Over The Air SUOTA Note Only Spectralink DECT Handset 7202 7212 7522 7532 7622 7642 7722 7742 and Spectralink DECT Handset Butterfly can be updated over the air SUOTA The Spectralink DECT Handsets has a hardware platform that supports dual flash par tition to ensure that the new firmware can be CRC16 verified before it takes over fro...

Page 132: ...ours typically means no User load therefore you can choose High priority 3 Click Save Note If you have already loaded handset firmware to the server enabled the Enable check box and set Start time to Immediately this will trigger firmware upload for the appropriate handsets as soon as you click Save Only handsets needing update will be updated The update progress is shown in the handset display an...

Page 133: ...ick Reboot now or Reboot when idle when active calls have ended if you want to restart the system 3 On the Wireless Server page under Service Status click Block if you want to block for new calls during firmware update 4 Click OK again Reading System Information Through the web based Administration Page of the Spectralink IP DECT Server it is possible to read the following system information l Gen...

Page 134: ...4 General Status Information This page provides general system information such as hardware and firmware information 1 Click Status and then click General The General Status page appears Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 135: ...ds documenting the sequence of activities It is possible to clear the message log buffer for Application logs The Audit log cannot be deleted except when performing a factory reset It is possible to stream an Application log whereas an Audit log cannot be streamed The different types of status are l emergency errors causing the system to malfunction for all calls l critical events that do not occu...

Page 136: ...erview of how the system is running You can get statistics of the following l Wireless Server l Media Resource l Base Station l Active Calls l Abnormal Releases l Traffic Distribution Note For more in depth information and to gain access to the Spectralink training material you must attend training and become Spectralink Certified Specialist Please visit http partneraccess spectralink com training...

Page 137: ... traffic load Erlang of the installation which is useful when determining the number of media resources needed l Click Statistics and then click Wireless Server The Trafic Statistics page appears You can delete all statistic traffic information by clicking Reset Statistics Statistics of Media Resource This page is useful to get statistical information about the media resource l Click Statistics an...

Page 138: ...and then click Base Station The Base Stations page appears Statistics of Devices l Click Statistics and then click Device The Devices page appears l Following columns contain important information about system performance o Abnormal releases o Connection handover cancelled o Call setup failed o Frame errors Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 139: ...ick Active Calls The Active Calls page appears Statistics of Abnormal Releases This page is useful to get statistical information about abnormal releases l Click Statistics and then click Abnormal Releases The Abnormal call releases page appears Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 140: ...erver it is possible to change the administration password For more information see Configuring Security Settings and Changing System Password on page 75 1 Click Configuration and then click Security 2 On the Security Configuration page enter the following data Field Setting Security Configuration Administrator Authentication Current password Enter the current password New username Enter a new use...

Page 141: ...ncrypted HTTP Optional HTTPS is forced by default If enabled HTTP support is supported instead of HTTPS Note Enabling unencrypted HTTP can cause pass words and other sensitive data to be transmitted in clear text on the network Allow remote logging Optional If enabled remote logging is allowed Remote logging allows for Spectralink debug tools to extract debug information from the unit Remove user ...

Page 142: ...base Firmware version is not affected Note You can also reset the Spectralink IP DECT Server and Spectralink DECT Media Resource to factory settings by pressing the Reset button For more information see Server and Media Resource Reset Button on page 42 To Reset System 1 Click Configuration and then click Factory Reset 2 Click Reset and then click OK All configuration and user data are being erased...

Page 143: ...port Export configuration Export Click Save if you want to export the configuration file Save the configuration file Import Export Import configuration Import Click Browse if you want to search for a configuration file to be imported select the relevant file and then click Load 3 Click Reboot Deleting Licenses 1 Click Administration and then click License 2 On the Licenses page under Loaded licens...

Page 144: ... the Spectralink IP DECT Server XML RPC SDK Documentation To setup the system to use MSF you must obtain the document XML RPC SDK from the following e mail address aims spectralink com or go to this site http www spectralink com partners app developers aims application form and fill out an applic ation form Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 145: ...nd statistics are automatically propagated between all the Spectralink IP DECT Server 6500 entities e g base stations media resources and server Note If a third party application is connected to the Spectralink IP DECT Server 6500 e g a messaging application or a nurse call application this application must connect to the master Spectralink IP DECT Server 6500 In case of a failure in the master se...

Page 146: ...t setup l Master server and backup slave server must have same firmware version l When upgrading firmware on base stations servers and media resources only reboot when all devices have been upgraded l Keep alive packets using TCP on port 50017 are sent between the master server and backup server Network administrators should make sure that this port is open How This Works The redundancy feature wo...

Page 147: ...ed on to the master server are also loaded on to the backup server or the system will not work Configuring Redundancy Note Not relevant to the Spectralink IP DECT Server 400 This section describes how to configure a redundant server solution l Configuration of the redundancy feature requires the acquisition of redundancy licenses l Configuration of setting is performed through the web based Admini...

Page 148: ...link IP DECT Server see Ordering Licenses on page 33 and Loading Licenses on page 34 Note The software license for the backup Spectralink IP DECT Server redundancy contains an ARI change license also known as ARI swap license meaning that the Spectralink IP DECT Server 6500 redundant solution only refers to the ARI code of the master Spec tralink IP DECT Server 6500 and not the ARI code of the bac...

Page 149: ...undancy Configuration Node type Single If selected this will disable redundancy and configure for stand alone normal single server solution Select Single if this device is to be a normal single server solution Master If enabled this will enable redundancy and configure the device as master server The system will be controlled by this device Select Master if this device is to be the master server S...

Page 150: ...alink IP DECT Server 6500 is changed to a backup Spectralink IP DECT Server 6500 or when a backup Spectralink IP DECT Server 6500 is moved to another solution Reset UUID Optional If enabled the UUID is reset if the UUID of the master server and backup server is not matching Redundancy Configuration Settings Failover time sec Enter value for failover time Failure time is the time in seconds from th...

Page 151: ... disable redundancy and configure for stand alone normal single server solution Select Single if this device is to be a normal single server solution Master If enabled this will enable redundancy and configure the device as master server The system will be controlled by this device Select Master if this device is to be the master server Slave If enabled this will enable redundancy and configure th...

Page 152: ... a backup Spectralink IP DECT Server 6500 is moved to another solution Reset UUID Optional If enabled the UUID is reset if the UUID of the master server and backup server is not matching Redundancy Configuration Settings Failover time sec Enter value for failover time Failure time is the time in seconds from the Spectralink IP DECT Server detects a failure until it initiates a fail over operation ...

Page 153: ...lution and the server address should be set to the address of the master Spectralink IP DECT Server 6500 After connecting to the master Spectralink IP DECT Server 6500 the base stations and media resource will automatically be configured to connect to the backup Spectralink IP DECT Server 6500 In the event that the master Spectralink IP DECT Server 6500 fails they will continue to provide ser vice...

Page 154: ... returns to operation it will resume its normal operation in cooperation with the backup Spectralink IP DECT Server 6500 However during the failover situation it will not be possible to change any configuration settings add or remove users or change the subscription state of any handset Permanent Failure on the Master Spectralink IP DECT Server 6500 If the master Spectralink IP DECT Server 6500 ha...

Page 155: ...rs are able to receive calls again Outgoing calls can be performed shortly after the failover The speed of re registration depends on the PBX and the load on the system Failure on the Backup Spectralink IP DECT Server 6500 A failure of the backup Spectralink IP DECT Server 6500 will induce a short service outage and the master Spectralink IP DECT Server 6500 will reestablish full operation as a si...

Page 156: ...ation on setting up long key and using the corporate phone book directory in the handset see the relevant Handset User Guide To Get Phone Book Data through LDAP Server or CSV File Configure the server to retrieve phone book data using LDAP server or by importing phone book data from a CSV file 1 Click Administration and then click Phonebook 2 On the Phonebook Configuration page enter the following...

Page 157: ...ve phone book data using LDAP server For an example of LDAP configuation see Example of LDAP Configuration on the next page URI Enter the URI of the LDAP server E g ldap example com Blind user Optional Enter the username used for authentication against LDAP Note It might be necessary to specify the path for user name DOMAIN username E g CN Manager DC example DC com Blind password Optional Enter th...

Page 158: ...es to replace or strip sep arated by a comma E g if the phone number is 45678912345 and that user has the extension 12345 then you specify 456789 in the Replace prefixes field Or if the phone number is 456789123456 and 06789123456 must be dialled then specify 45 0 Load interval Enter the interval in seconds for querying the LDAP server for updates Default value 3600 sec Possible values 60 999999 s...

Page 159: ...Field1 Field2 Field3 Field4 Field5 Field1 Field2 Field3 Field4 Field5 The labels are column names displayed in the handset The fields are the actual data for the records See the example below Name Phone Mobile Department Title Peter Petersen 1000 20123456 Sales Manager Niels Nielsen 1001 20123457 R D Developer Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 160: ...s possible to let the next nurse use a different handset fully charged because it was not used by the previous nurse This way several nurses can share a line number without sharing a device Normally 30 minutes of charging of the handset will be sufficient every 24 hours thus under normal con ditions it is not necessary to have extra devices only for the purpose of charging while not in use l The s...

Page 161: ...ibility on the next page l Configuration of handset sharing including o Configuration of user sign in sign out For more information see User Sign in Sign out on page 164 o Adding Devices to Server For more information see Adding Devices to Server on page 171 o Adding Users to Servers For more information see Adding Users to Server on page 174 o Handset Sharing and Provisioning For more information...

Page 162: ...must run firmware PCS14_ or newer l The server must run firmware PCS12M_ or newer Handset model Handset sharing support Clear Call Message list Non Spectralink handsets Not supported Not supported Spectralink 7202 7212 Supported Not supported Spectralink 7522 7532 Supported Not supported Spectralink 7622 7642 Supported Supported Spectralink 7722 7742 Supported Supported Spectralink Butterfly Suppo...

Page 163: ... not l Without handset sharing the DECT access code is part of the data for a specific user l With handset sharing the DECT access code is not a part of the data for a specific user it is a part of the data for a specific device If a user specific DECT access code is configured before installing the handset sharing license the DECT access code will be used as device DECT access code and as initial...

Page 164: ... to the state it was in before the sign in sign out was initiated If a sign in sign out is initiated while the user is busy the sign in will not be allowed Configuring Handset Login Enable Disable Handset Login on Spectralink IP DECT Server 1 Ensure that support of the relevant call handler is enabled Configuration relevant Call handler e g Skype for Business 2 Click Configuration and then click W...

Page 165: ...ion Administration Base Sta tion Wireless Server Configuration Media resources Allow new Optional If enabled new media resources are allowed to con nect to the server Add new as active Optional If enabled new media resources will become active when added Otherwise they must be activated manu ally under Administration Media Resource Media Resource page Require encryption Optional If enabled the con...

Page 166: ...e value in case of con flicting ports Multicast signaling Optional Multicast signaling is optimal when having many base stations and is required with more than 256 base sta tions connected If enabled this will impose multicast support for the net work Multicast address Optional Multicast address used for signaling Please refer to RFC2365 and RFC4291 for details Multicast TTL Optional The TTL is us...

Page 167: ...ity 96 flash 64 immediate 32 priority 0 routine lowest priority Default value 184 Expedited Forwarding Wireless Server Configuration Handsets Handset sharing Optional Only visible if Handset Sharing License loaded Enabled by default when Handset Sharing License is loaded Disable this if handset sharing is not to be allowed For more information about using handset sharing and configuring handset lo...

Page 168: ...ng to allow handset to handset messaging without an external application is suported Wireless Server Configuration Feature codes Enable Optional If enabled feature codes for controlling features from the handsets can be used Call forward unconditional enable Optional Enable call forward unconditional by dialing this code 21 including the desired extension E g 21 Note It is possible to change the c...

Page 169: ... Optional If enabled allow DECT Server to use this long key press for phone book Enable Long Press Key5 Phone book Optional If enabled allow DECT Server to use this long key press for phone book Enable Long Press Key6 Undefined Optional If enabled allow DECT Server to use this long key press Enable Long Press Key7 Undefined Optional If enabled allow DECT Server to use this long key press Enable Lo...

Page 170: ...he user to the Call handler and the handset will be ready for use Signing out again from the handset is likewise performed by invoking MSF function 9 Signing into a Device from the Handset 1 When signing in using long key press 9 you can choose between PIN Sign in or Sign in PIN Sign in is only visible if PIN authentication is available and configured on the server of the call handler e g Skype fo...

Page 171: ...wo categories l Device data handset Device specific data include an IPEI mandatory and an access code optional The access code is used for subscribing the device to the Spectralink IP DECT Server l User data username standby text display name etc If a user is signed in it will be visible in the Users List Users User List Editing the user name will allow the administrator to sign in a user to the d...

Page 172: ...d optional new PIN code field Note You may fill the new PIN code field for added security to prevent other users from linking a handset with your user profile When a user is linked to a handset the IPEI link is active and can be clicked upon and the IPEI text field holds the IPEI number of the linked handset Note A User with no linked handset will show an inactive IPEI link and no IPEI number in t...

Page 173: ...sion the link will take you to the User profile of the linked handset And when clicking on the IPEI link from the User profile that will take you to the Device profile of the linked handset Note If the user is not linked to a handset this Username Extension link is inactive and there is no extension number in the associated text field For examples of handset sharing see Handset Sharing Setup Examp...

Page 174: ...in a user to the device or alternatively to sign out a user l User User data are data specific to a specific user The Standby text is displayed in the handset when the user is signed in If no user is currently signed in to a device the device will display Signed out The user PIN code is used by the user to sign in to a device l SIP The sip category consists of SIP data specific to the user l Featu...

Page 175: ... is recommended to restrict device subscription with a system access code For more information about provisioning see Provisioning Guide Handset Sharing Setup Examples l Any handset can be linked with any User at any given time l Handset sign in and sign out using PIN code l IPEI link is active when User is linked to a handset l PIN code field is used during handset sign in Once the Handset Sharin...

Page 176: ... number and optional access code used when the handset is subscribed to the Spectralink IP DECT Server Note The access code should not be mistaken for the PIN code When subscribing a handset you can choose to link the handset to an existing vacant User dur ing the subscription process You can also work the other way around so that when creating a User you can choose to link the user to an existing...

Page 177: ... SIP Server Above you see how a Device profile is linked to a User profile Notice how the IPEI number and the Username Extension number are associated indicating a link between the Device and User Also notice the User registration with the SIP Server Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 178: ... if you need to do this for many handsets use the handset man agement tool 3 To sign in press and hold key 9 until the sign in screen appears 4 Select Sign In and then enter the User number typically your Extension number 5 Enter the PIN code 6 If sign in is successful the standby text will show in the display 7 Long press key 9 to sign out The standby text will show signed out upon successful sig...

Page 179: ...pectralink DECT Repeater Spectralink DECT Repeater 1G8 2 channels with external antenna K018B 0244 0000 Spectralink DECT Repeater 1G9 2 channels with external antenna K018B 0244 1000 Spectralink DECT Repeater 1G8 2 channels without external antenna K018 0244 1100 Spectralink DECT Repeater 1G9 2 channels without external antenna K018 0244 1200 Spectralink DECT Repeater 1G8 4 channels with external ...

Page 180: ...ell License 1407 5550 License bundle for Spectralink IP DECT Server 400 incl 30 users 12 speech channels Lync SRTP License 1407 5540 License bundle for Spectralink IP DECT Server 400 incl 30 users 12 speech channels Multi Cell Liense 1407 5560 Cisco Unified CM Enhanced features License for Spectralink IP DECT Server 400 1407 5490 LAN Synchronization License for Spectralink IP DECT Server 400 1407 ...

Page 181: ...andancy 1407 5250 Software License for Backup Spectralink IP DECT Server 6500 Redundancy with ARI Swap License 1407 5260 LAN Synchronization License for Spectralink IP DECT Server 6500 1407 5610 Frequency Swap License for for Spectralink IP DECT Server 6500 1407 5620 Cisco Unified CM Enhanced features License for Spectralink IP DECT Server 6500 1407 5495 MS Lync Interop License for Spectralink IP ...

Page 182: ...us To make a packet capture from the web based Administration Page of the Spectralink IP DECT Server 1 Click Status and then click Packet Capture 2 On the Packet Capture page enter the following data Field Setting Packet Capture Filters Capture SIP Optional If enabled SIP signalling is captured Capture SIPS decrypted Optional If enabled decrypted SIPS TLS signalling is captured Capture external RT...

Page 183: ...load and save the package capture file pcap cap file 4 If you want to stream a package click Stream A pcap file is downloaded automatically Network Diagnose 1 Click Status and then click Network Diagnose 2 On the Network Diagnose page under Host enter the relevant IP address or domain name 3 Click Ping to send a ping request to the host to check if network is connected 4 If you want to trace the r...

Page 184: ...IP DECT Server hardware PCS Hardware version General Status Firmware PartNo Partnumber of the Spectralink IP DECT Server firmware PCS Firmware version Build Firmware build General Status Quick status SIP OK if all enabled SIP users are registered to the SIP server KWS redundancy Only visible if license loaded OK if the connection to redundancy peer is OK Base stations OK if no synchronization loop...

Page 185: ...vents that do not occur under normal oper ation cause major malfunction l error events that do not occur under normal oper ation cause minor malfunction l warning events that do not occur under normal oper ation may cause malfunction l notice info events that occur under normal operation An Application log is a file of events logged by the system An Audit log is a chronological set of records docu...

Page 186: ...ption status E g Allowed Defined under Con figuration Wireless Server Status Packet Capture Field Setting Packet Capture Filters Capture SIP Optional If enabled SIP signalling is captured Capture SIPS decrypted Optional If enabled decrypted SIPS TLS signalling is captured Capture external RTP Optional If enabled all voice packages from other endpoints are cap tured Capture internal RTP Optional If...

Page 187: ...ess it is also necessary to configure other network settings below such as DNS and NTP settings For more information see also Recommended Network Con figuration on page 63 IP addr Optional Enter the IP address of the Spectralink IP DECT Server Netmask Optional Enter a new network mask Contact your system administrator for more information Gateway Optional Enter the IP address of the default gatewa...

Page 188: ... another network General Configuration Ethernet VLAN Optional It is possible to enter the VLAN Identifier VID according to IEEE 802 1Q specifying the VLAN to which the device belongs Note If this setting is used network access from outside the VLAN is no longer possible The Spectralink IP DECT Server 400 6500 supports 4094 dif ferent VLANs Possible values 1 4094 General Configuration DNS Domain Na...

Page 189: ...HCP assigned UPnP can be used to easily identify the IP address of the device Note If My Network Places in Windows is setup to show icons for networked UPnP devices every Spectralink IP DECT Server Media resource and Base station will be present in My Network Places Broadcast announcements Optional Specifies if UPnP announcements are broadcasted If enabled the device broadcasts announcements auto ...

Page 190: ...he SNMP is allowed and the server will respond to SNMP requests Community Optional SNMP Community name public The server will respond to requests from a manager in this community Trap host Optional Address of SNMP trap host to which SNMP traps are sent Trap community Optional SNMP trap Community name used for sending traps System location Optional Information about the physical location of this ho...

Page 191: ...e and time Optional If enabled date and time will be sent to the handsets when a call is terminated Default value Enabled System TX power Optional Used for controlling reducing the output power of all con nected base stations supporting power control Unless set to default this will override any base station specific power setting Default value Default 250 mW Note It is possible to define a TX powe...

Page 192: ...nection between the base station and the Spectralink IP DECT Server is required to be encryp ted Note Enabling this will only allow base stations with firm ware PCS17Fa or newer to connect If not enabled the connection will be encrypted if the base station supports encryption RFP port range start Port range start for RFP local RTP ports Default value 57000 Note It is possible to change the value i...

Page 193: ...ed for LAN sync The values are entered in decimal Network priority Packets with higher TOS DiffServ have higher priority on the network 184 critical highest priority 96 flash 64 immediate 32 priority 0 routine lowest priority Default value 184 Expedited Forwarding Wireless Server Configuration Handsets Handset sharing Optional Only visible if Handset Sharing License loaded Enabled by default when ...

Page 194: ...ing to allow handset to hand set messaging without an external application is suported Wireless Server Configuration Feature codes Enable Optional If enabled feature codes for controlling features from the handsets can be used Call forward unconditional enable Optional Enable call forward unconditional by dialing this code 21 including the desired extension E g 21 Note It is possible to change the...

Page 195: ...ed allow DECT Server to use this long key press for phone book Enable Long Press Key6 Undefined Optional If enabled allow DECT Server to use this long key press Enable Long Press Key7 Undefined Optional If enabled allow DECT Server to use this long key press Enable Long Press Key8 Undefined Optional If enabled allow DECT Server to use this long key press Enable Long Press Key9 Handset Sharing Opti...

Page 196: ...xpiration can only be disabled by a factory reset Configuration Factory Reset Security Configuration Data protection Allow unencrypted HTTP Optional HTTPS is forced by default If enabled HTTP support is supported instead of HTTPS Note Enabling unencrypted HTTP can cause passwords and other sensitive data to be transmitted in clear text on the net work Allow remote logging Optional If enabled remot...

Page 197: ... 12 Click Import Certificate if you want to import the certificate Click Remove if you want to remove a certificate Certificates CA certificates Click Browse to find the relevant CA certificate file pem file E g a custom list of CA certificate files Click Import List if you want to import the list It is also possible to remove all CA certificates Clear List restore default list of public CA certif...

Page 198: ...Register each endpoint on sep arate port Optional If enabled separate local ports for each endpoint are used instead of the global local port Send all messages to current regis trar Optional If enabled all non REGISTER requests to the current registar will be sent when more proxies are available Registration expire sec The maximum time between re registrations The registrar can signal a shorter ti...

Page 199: ...s the default If this setting is enabled UDP and TCP are allowed as fallback if TLS fails Default value Disabled TCP ephemeral port in contact address Optional If enabled the TCP ephemeral port the local TCP port of the outgoing connection to the contact header used in outgoing SIP messages is added SIP Configuration Proxies Proxies Optional Priority The priority for using this proxy Possible Valu...

Page 200: ...waiting indication Enable indication Optional If enabled MWI is displayed in the handset Enable subscription Optional If enabled you can subscribe to MWI indications from the SIP proxy Subscription expire sec Enter the number of seconds before MWI subscription will be renewed Default value 3600 sec SIP Configuration Media Packet duration msec Packet duration for transmitted RTP Packets Possible va...

Page 201: ... Optional Enter TURN server address TURN username Optional Enter TURN server username If left blank the per user authentication username will be used TURN password Optional Enter TURN pass word If left blank the per user authentication password will be used SIP Configuration Call status Play on hold tone Optional If enabled on hold tone is received in remote end when placed on hold Note This might...

Page 202: ...r server enter the fixed IP address for the backup Spec tralink IP DECT Server 6500 If backup server enter the fixed IP address for the master Spec tralink IP DECT Server 6500 Redundancy Configuration System identification UUID Optional The UUID unique ID of the redundant system This must be the same for master server and backup server for replication to be performed The master server automaticall...

Page 203: ... Provisioning Field Setting Provisioning Configuration Server Method The Spectralink IP DECT DECT Server must know the pro tocol and address of server containing the firmware and con figuration The Spectralink IP DECT DECT Server can use the fol lowing methods to obtain the provisioning server URL l Disabled The Spectralink IP DECT DECT Server will not use provisioning l Static The administrator m...

Page 204: ...for checking updates automatically Time hh mm Enter a value to poll the provisioning server at a specific time each day Leave it empty if not using polling NOTIFY check_sync Possible values Disabled Update or Reboot If disabled is selected polling defining specific time interval for automatic check for new updates is used If Update is selected then SIP Notify Check Sync is used for automatic notif...

Page 205: ...r no firmware download Handset 75x2 76x2 and 77x2 series Enter name of firmware image file Over the Air bin Must match file name on provisioning server Leave empty for no firmware download Handset 72x2 series Enter name of firmware image file Over the Air bin Must match file name on provisioning server Leave empty for no firmware download Handset OEM Enter name of firmware image file Must match fi...

Page 206: ...ote A SIP REGISTER will not be sent before there is an IPEI number present Note Programming of IPEI number into the system database is necessary to enable service to the handset Note If handset sharing is used the IPEI label will be a link that you can click on and link to a device For more information see Adding Devices to Server on page 171 Access code Optional Administrators can define a system...

Page 207: ...xample org Note If not configured the default domain entered under SIP configuration will be used Displayname Optional Enter the name of the user e g caller ID E g John Doe in John Doe sip 1234 example org Note If Cisco license is loaded the Cisco Unified CM will not use this but it may ease the administration of users within the Spectralink IP DECT Server Authentication user Optional Enter the us...

Page 208: ...8 Field Setting User Features Call forward unconditional Optional A Call Forward Unconditional an extension to forward calls to can be added removed via the web based Administration Page Spectralink IP DECT Server 400 6500 Installation and Configuration Guide ...

Page 209: ...n Id E g 0024 065F 3C25 714C IPEI Optional If a specific handset is being subscribed for this extension enter the IPEI number of the actual handset The IPEI number is readable from the label on the product If this is not the case this field can be left empty and it will auto fill when the handsets subscribe Note A SIP REGISTER will not be sent before there is an IPEI number present Note Programmin...

Page 210: ...ller ID E g John Doe in John Doe sip 1234 example org Users List User Handset firmware update Field Setting Handset firmware update Options Update load Select relevant upload capacity Possible values Low Medium or High Default value Medium Amount of simultaneous updates is proportional to number of devices available present in the system Start time Default value Now If you want to upload later sel...

Page 211: ...ct Windows 1252 Import Export Users Export user data CSV format If you want to save the user data file in CSV format click Save The CSV format can be imported back into the server XML format If you want to save the user data file in XML format click Save The XML format is used for provisioning For more information see Provisioning Guide Import Export Users Delete users Delete all users If you want...

Page 212: ...ore information about ordering licenses see Ordering Licenses on page 33 Licenses Loaded licenses Key Overview of loaded licenses Click Delete if you want to delete a license Licenses Active License Summary Users Shows details about user license E g 30 Features Shows details about enabled license required features E g Handset Sharing Enhanced Provisioning Interface Spectralink IP DECT Server 400 6...

Page 213: ... cluster devices that are located at the same location To assign a cluster to the media resource select the relevant cluster from the list For information about defining clusters see Configuring Clusters on page 90 Disabled Optional If enabled the media resource will be disabled Note If Add new as active is enabled Configuration Wireless Server Media resources then this will be dis abled by defaul...

Page 214: ...dd new as active is enabled Configuration Wireless Server Base stations then this will be dis abled by default when adding a new base station TX power Optional Used for controlling the output power for this specific base station Select another value from the list if you need to change the output power Default value Default 250 mW Note If a system TX power other than default is set for the whole sy...

Page 215: ...l If enabled the base station will be auto synchronized while deploying the system Note This must only be used while deploying the system Primary radio sync RPN Optional RPN identifying the base station used for primary radio syn chronization Secondary radio sync RPN Optional RPN identifying the base station used for secondary radio synchronization Base Station RSSI map Only visible if more than o...

Page 216: ...e The encoding depends on the software that was used to generate the CSV file If you use Microsoft Windows you will probably select Windows 1252 Number fields Enter the indexes of the columns containing dialable numbers Phonebook Configuration LDAP LDAP Enable this if you want to configure the server to retrieve phone book data using LDAP server For an example of LDAP configuation see Parameter Ov...

Page 217: ...tional Enter the phone number prefixes to replace or strip separated by a comma E g if the phone number is 45678912345 and that user has the extension 12345 then you specify 456789 in the Replace prefixes field Or if the phone number is 456789123456 and 06789123456 must be dialled then specify 45 0 Load interval Enter the interval in seconds for querying the LDAP server for updates Default value 3...

Page 218: ... version PCS if a firm ware file has been uploaded Note Once uploaded default firmware will remain on the server until overwritten Note If the Use firmware as default check box on the Update firmware page is enabled Firmware Wireless Server or Configuration Provisioning Firmware then the server firmware is uploaded as default for all base stations and media resources recommended For the files to b...

Page 219: ...n see Pro visioning Guide Force Optional When Force is enabled the media resources will be updated at the selected Start time If Force is disabled the media resources will be updated when they become idle after the selected Start time Start time Optional Default value Immediately If you want to upload later select an appropriate time within the next 24 hours Click Save Update media resource firmwa...

Page 220: ...fault value Disabled Enable this if you want to make automatic update possible The base stations will be automatically updated using the default firmware Also new base stations automatically update to new default firmware when connected Note If the default firmware version changes the update pro cess will start automatically according to the chosen values in the Force and Start time fields Note Us...

Page 221: ...matic update Enable Optional Enable This will make automatic update possible Only in charger Optional If enabled only handsets in charger will be updated Start time Optional Default value Immediately If you want to upload later select an appropriate time within the next 24 hours System load Optional Select relevant upload capacity Possible values Low Medium or High The load corresponds to the numb...

Reviews: