
46
R
EFERENCE
& I
NSTALLATION
M
ANUAL
leaving the protected area, without giving them access to any other alarm system operations.
One-Touch Regular Arming
Press and hold the
[
ENTER
]
key for 3 seconds* to arm all zones in the partition.
One-Touch Force Arming
Press and hold the
[
FORCE
]
key for 3 seconds* to bypass any open Force Zones.
One-Touch Bypass Programming
Press and hold the
[
BYP
]
key for 3 seconds* to access Bypass Programming Mode.
One-Touch Stay Arming
Press and hold the
[
STAY
]
key for 3 seconds* to arm all zones not defined as Stay Zones.
Fast Exit
- When the system is already Stay Armed:
•
To Exit and Stay Arm:
Press and hold the
[
STAY
]
key for 3 seconds*. The system will switch to Exit Delay. At the end of the Exit
Delay period, the system will return to Stay Arming.
•
To Exit and Regular Arm:
Press and hold the
[
ENTER
]
key for 3 seconds*. The system will switch to Exit Delay. At the end of the
Exit Delay period, the control panel will switch to Regular Arming.
•
To Exit and Force Arm:
Press and hold the
[
FORCE
]
key for 3 seconds*. The system will switch to Exit Delay. At the end of the
Exit Delay period, the control panel will switch to Force Arming.
13.10 KEYSWITCH ARMING
A keyswitch can be used to arm and disarm the system. Assign the keyswitch to a specific partition and program the keyswitch to
Stay or Regular Arm the assigned partition. Also program the keyswitch to function as a Maintained or Momentary keyswitch. To
arm the system using a Maintained Keyswitch, set the keyswitch to the
ON
position. To disarm the system set the keyswitch to the
OFF
position. To arm the system using a Momentary Keyswitch, set the keyswitch to the
ON
position then turn it back to the
OFF
position. Repeating this sequence will disarm the system.
13.11 PANIC ALARMS
In case of emergency, the Spectra system provides up to three panic alarms. These panic alarms, if programmed, will immediately
generate an alarm after pressing and holding two specific keys for two seconds, as described below.
Press and hold keys
[1]
and
[3]
for a panic alarm.
Press and hold keys
[4]
and
[6]
for a panic or medical alarm.
Press and hold keys
[7]
and
[9]
for a panic or fire alarm.
13.12 AUTO-ARMING
(NOT TO BE USED WITH UL INSTALLATIONS)
Each partition can be programmed to arm every day at the time specified by the Auto-Arm Timer or for the period specified by the
No Movement Timer. The user can program the Auto-Arm Timer by using the System Master Code, Master Code 1 or Master
Code 2.
Please note that the control panel will enter a 60-second Exit Delay period before arming the system. At this point, Auto-
Arming can be cancelled by entering a valid access code.
13.13 ALARM MEMORY DISPLAY
A record of all alarm situations that occur will be stored in memory. After disarming the system, pressing the
[
MEM
]
key will display
which zones were in alarm during the alarm period. To exit the Alarm Memory Display, press the
[
CLEAR
]
key. The control panel
will erase the contents of the alarm memory every time the system is armed.
13.14 PROGRAMMING CHIME ZONES
Users can program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to emit a rapid intermittent
beep tone (
BEEP
-
BEEP
-
BEEP
-
BEEP
) advising the user every time it is opened. Each keypad must be Chime Programmed
separately.
10-Z
ONE
LED K
EYPAD
:
Press and hold any key from
[1]
to
[10]
for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For example, press and
hold the [1] key to enable chiming on zone 1. If after pressing and holding a key, the keypad emits a confirmation beep, this
means the chime feature has been enabled for that zone. If the keypad emits a rejection beep, this means the chime feature has
been disabled for the corresponding zone.
16-Z
ONE
LED K
EYPAD
:
Press and hold the
[9]
key. Enter the 2-digit (01 to 15) zone number(s). When the corresponding LED is on, the zone is chimed.
When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press
[
ENTER
]
.
*
If you have access to both partitions after activating a one-touch feature, press the key corresponding to the desired partition.
To select both partitions, press the
[1]
key then after the confirmation beep press the
[2]
key.
Summary of Contents for 1759ex
Page 1: ...1759EX V1 0 REFERENCE INSTALLATION MANUAL 433MHZ 868MHZ 1759EX...
Page 2: ......
Page 55: ......