
S
PECTRA
1759EX
27
an alarm. This option is not permitted on UL systems.
[1]
OFF /
[2]
ON:
Trouble Only
If the system is armed
and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting (see
If the system is disarmed
and a tamper wiring failure occurs on a zone, a Tamper/Zone Wiring Failure will appear in the
keypads’ Trouble Display (see page 42) and the control panel will transmit the appropriate Zone Tamper report code (see page 30).
[1]
ON /
[2]
OFF:
Silent Alarm
If the system is armed
and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting
In a disarmed system
, it functions the same as the Trouble Only setting, but it will also generate a silent alarm. A
silent alarm will not trigger any bells or sirens, but the system will have to be disarmed.
[1]
ON /
[2]
ON:
Audible Alarm
In an armed system
and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting (see
In a disarmed system
, it functions the same as Trouble Only setting, except it will also generate an audible alarm.
8.3.1
T
AMPER
B
YPASS
O
PTIONS
Section [132]: Zone Options
Option [3] OFF = Will generate a tamper if detected on a bypassed zone (default)
Option [3] ON
= Tampers on bypassed zones will be ignored
With option
[3]
on, the Tamper Recognition feature follows the zone bypass definition. This means the control panel
will ignore any tampers detected on a bypassed zone. With option
[3]
off, Tamper Recognition ignores the bypass
definition. This means the control panel will generate an incident as per Tamper Recognition settings if a tamper or
wire fault occurs on a bypassed zone.
8.4
KEYPAD PANIC OPTIONS
Section [128]: General Options
Option [1] OFF = Emergency Panic Disabled (default)
Option [1] ON = Emergency Panic Enabled
Press the
[1]
and
[3]
keys simultaneously on the keypad for 2 seconds to generate a silent or audible alarm as defined by option
[4]
.
Option [2] OFF = Auxiliary Panic Disabled (default)
Option [2] ON = Auxiliary Panic Enabled
Press the
[4]
and
[6]
keys simultaneously on the keypad for 2 seconds to generate a silent or audible alarm as defined by option
[5]
.
Option [3] OFF = Fire Panic Disabled (default)
Option [3] ON = Fire Panic Enabled
Press the
[7]
and
[9]
keys simultaneously on the keypad for 2 seconds to generate a silent or audible alarm as defined by option
[6]
.
Option [4] OFF = Emergency Panic is Silent (default)
Option [4] ON = Emergency Panic is Audible
Option [5] OFF = Auxiliary Panic is Silent (default)
Option [5] ON = Auxiliary Panic is Audible
Option [6] OFF = Fire Panic is Silent (default)
Option [6] ON = Fire Panic is Pulsed
Silent alarm
:
The control panel emits a Confirmation Beep and transmits the appropriate Panic report code if programmed in section [195]. The
control panel will not enable the keypad buzzers or the control panel’s
BELL
output (no audible alarm).
Audible alarm
:
Same as silent alarm, except the keypad buzzers and the
BELL
output will activate until a user cancels the alarm (disarms) with a
valid User Access Code or when the Bell Cut-Off Timer elapses (see page 26).
Fire (pulsed) alarm
:
Same as audible operation, except that the
BELL
output will be pulsed as shown in Figure 5.2 on page 16.
Whether the system is partitioned or not, the control panel will report all panic alarms to partition 1.
8.5
PANIC LOCKOUT TIMER
Section [094]
When a panic alarm is activated, the control panel can ignore the disarm signal from a remote control for a specified period. This
prevents an aggressor from disarming the system by remote control during a panic situation. In section [094] enter a 3-digit value
(000 to 255, 000 = disabled) representing the number of seconds that the remote controls will be locked out of the system.
Summary of Contents for 1759ex
Page 1: ...1759EX V1 0 REFERENCE INSTALLATION MANUAL 433MHZ 868MHZ 1759EX...
Page 2: ......
Page 55: ......