Figure 5.1: Spectra Zone Programming
5.5
ZONE DEFINITIONS
As demonstrated in Figure 5.1, sections [001] to [015] represent zones 1 through 15 respectively, where the first digit in each of
these sections represents the zone's definition. Also, refer to
on page 18. To disable a zone, clear the contents of the
section corresponding to the desired zone by pressing the
[
FORCE
]
key 3 times and pressing
[
ENTER
]
. There are 9 available Zone
Definitions, which are described as follows.
5.5.1
E
NTRY
D
ELAY
1
Sections [001] to [015]: Zones 1 to 15, First Digit = 1
When the system is armed and a zone defined with Entry Delay 1 opens, the control panel will generate an alarm after
the programmed Entry Delay 1 Timer elapses. This is to provide users with enough time to enter the protected area
and disarm the system. To program the Entry Delay 1 Timer, key in the desired 3-digit delay value (000 to 255
seconds, Default = 45 seconds) into section [069]. Entry Delay zones are commonly used at the entry/exit points of the
protected area (i.e. front/back door, garage, etc.). Using different Entry Delays (see Entry Delay 2 below) is useful
when, for example, one entry point requires a longer delay than the other entry point or in a partitioned system where
each partition may require a different Entry Delay.
5.5.2
E
NTRY
D
ELAY
2
Sections [001] to [015]: Zones 1 to 15, First Digit = 2
Entry Delay 2 zones are identical to the Entry Delay 1 zones (see section 5.5.1), except it uses a separate Entry Delay
Timer. To program the Entry Delay 2 Timer, key in the desired 3-digit delay value (000 to 255 seconds, Default = 45
seconds) into section
[070].
This timer is also used as the Stay Delay timer (see
Zone Definitions
1 -
Entry Delay 1
2 -
Entry Delay 2
3 -
Follow
4 -
Instant
5 -
24Hr. Burglary
6 -
24Hr. Buzzer
Additional definitions for
on-board terminals:
7 -
Keyswitch
8 -
24Hr. Fire
9 -
24Hr. Delayed Fire
Press the
[
ENTER
]
key
Enter the
[
INSTALLER
CODE
]
Key in 3-digit
[
SECTION
]
Zone Definition
First Digit
Zone Partition
Assignment
Second Digit
Zone Options
Feature Select
Press
[
ENTER
]
[001]
= Zone 1
[009]
= Zone 9
[002]
= Zone 2
[010]
= Zone 10
[003]
= Zone 3
[011]
= Zone 11
[004]
= Zone 4
[012]
= Zone 12
[005]
= Zone 5
[013]
= Zone 13
[006]
= Zone 6
[014]
= Zone 14
[007]
= Zone 7
[015]
= Zone 15
[008
] = Zone 8
Zone Partition Assignment
1 -
Zone Assigned to Partition 1
2 -
Zone Assigned to Partition 2
3 -
Zone Assigned to both Partitions
Zone Options
[1]
Auto Zone Shutdown Enabled
[2]
Bypass Enabled
[3]
Stay Zone
[4]
[5]
Zone Alarm Type
OFF OFF Audible Alarm (steady)
OFF ON
Audible Alarm (pulsed)
ON
OFF Silent Alarm
ON
ON
Generates only a report
[6]
Intellizone
[7]
Delay alarm transmission
[8]
Force Zone
Keyswitch Options
[1]
OFF= Maintained
ON = Momentary
[2]
OFF = Regular Arm
ON = Stay Arm
Keypads beep twice
Select
one
Select
one