Aquifer Expedition Hose Connections
Product
Flow
meter
Product Outlet
Warning
Pressure in the product tubing must nev-
er exceed 5psi (0.3bar)
at any time or the
membrane will be permanently damaged.
The product water should fall into the stor-
age tank through an air gap so there is no
back pressure on it.
DO NOT!
feed the
product into a manifold or the bottom of a
tank. Make sure that there is no possible re-
striction in this piping.
Note: The product flow meter displays the
flow per hour. In normal operation the flow
will go up and down as the Clark Pump
Shifts.
It is a good idea to keep a record of the flow
rate and system pressure so you under-
stand system performance. This data will
inform any future maintenance or service
requirements.
Clear product
water
tubing with
quick
-
connects
Clark Pump
Salinity Gauge
Product Water
Product water
from membrane
via clear
1/4”
hose
Prefilter with
gauge
Membranes