17
Aquifer Expedition Storage Procedure
1.
Perform a fresh water flush as described in the Normal Operation section. Leave
one gallon of water in the bucket.
2.
Place the brine discharge in the bucket.
3.
Add one packet of SC
-
1 storage chemical to the bucket and stir until mostly dis-
solved. The chemical will dissolve in about an hour, but don
’
t worry if it doesn
’
t all
dissolve, it will not hurt the pump.
4.
Make sure the pressure relief valve on the Clark Pump is OPEN
(unpressurized) by unscrewing it
1
/
2
turn counterclockwise.
6. Start and run the well pump to circulate
the solution for about ten minutes.
7.
Stop the well pump.
Leave the pressure relief open.
Clean Up
•
Drain hoses as much as possible so
there is no water to drip inside the case
when the unit is stored.
•
Disconnect the electrical connections and remove and stow the product tubing if
the unit is to be transported.
•
Remove hoses and stow it away in the case (connect quick fittings so any water in
the hose is captured.
•
Remove the pre
-
filter from its housing and replace with a clean dry filter element.
•
Clean and dry the submersible well pump and stow inside the case.
•
Allow the interior of the case to dry out if possible before storing.